Open Access. Powered by Scholars. Published by Universities.®

Power and Energy Commons

Open Access. Powered by Scholars. Published by Universities.®

Controls and Control Theory

2012

Institution
Keyword
Publication
Publication Type
File Type

Articles 1 - 19 of 19

Full-Text Articles in Power and Energy

Z-Source Inverter For Automotive Applications, Omar Ellabban, Joeri Van Mierlo Dec 2012

Z-Source Inverter For Automotive Applications, Omar Ellabban, Joeri Van Mierlo

Omar Ellabban

No abstract provided.


Capacitor Voltage Control Techniques Of The Z-Source Inverter: A Comparative Study, Omar Ellabban, Joeri Van Mierlo, Philippe Lataire Dec 2012

Capacitor Voltage Control Techniques Of The Z-Source Inverter: A Comparative Study, Omar Ellabban, Joeri Van Mierlo, Philippe Lataire

Omar Ellabban

The Z-source inverter (ZSI) is a recently proposed single-stage power conversion topology. It adds voltage boost capability for complementing the usual voltage buck operation of a traditional voltage source inverter (VSI) with improved reliability. In this paper, a single-loop and dual-loop capacitor voltage control techniques for the ZSI are digitally designed based on a third order small signal model of the ZSI, implemented using a digital signal processor (DSP) and compared. Simulation and experimental results of a 30 kW ZSI during input voltage changes, load disturbances and steady state operations are presented and compared. The results show that the dual-loop …


Smart Wall Plug Design For The Dc House Project, Edward Constant Sibal Dec 2012

Smart Wall Plug Design For The Dc House Project, Edward Constant Sibal

Master's Theses

The DC House project at Cal Poly State University faces a challenge of supplying DC voltage to household appliances. Each appliance in the DC House constitutes a DC load that has a unique voltage and power rating, hence the need to develop a smart DC wall plug that will automatically adjust to the operating voltage required by any DC load. This thesis entails a proof of concept design of the smart DC wall plug which can automatically detect an appliance’s voltage rating. The design employs a dc-dc converter in conjunction with a microcontroller to sense load current to properly adjust …


Mle+: A Tool For Integrated Design And Deployment Of Energy Efficient Building Controls, Willy Bernal, Madhur Behl, Truong Nghiem, Rahul Mangharam Oct 2012

Mle+: A Tool For Integrated Design And Deployment Of Energy Efficient Building Controls, Willy Bernal, Madhur Behl, Truong Nghiem, Rahul Mangharam

Madhur Behl

We present MLE+, a tool for energy-efficient building automation design, co-simulation and analysis. The tool leverages the high-fidelity building simulation capabilities of EnergyPlus and the scientific computation and design capabilities of Matlab for controller design. MLE+ facilitates integrated building simulation and controller formulation with integrated support for system identification, control design, optimization, simulation analysis and communication between software applications and building equipment. It provides streamlined workflows, a graphical front-end, and debugging support to help control engineers eliminate design and programming errors and take informed decisions early in the design stage, leading to fewer iterations in the building automation development cycle. …


Green Scheduling For Radiant Systems In Buildings, Truong X. Nghiem, Madhur Behl, George J. Pappas, Rahul Mangharam Oct 2012

Green Scheduling For Radiant Systems In Buildings, Truong X. Nghiem, Madhur Behl, George J. Pappas, Rahul Mangharam

Madhur Behl

In this report we look at the problem of peak power reduction for buildings with electric radiant floor heating systems. Uncoordinated operation of a multi-zone radiant floor heating system can result in temporally correlated electricity demand surges or peaks in the building’s electricity consumption. As peak power prices are 200-400 times that of the nominal rate, this uncoordinated activity can result in high electricity costs and expensive system operation. We have previously presented green scheduling as an approach for reducing the aggregate peak power consumption in buildings while ensuring that indoor thermal comfort is always maintained. This report extends the …


Green Scheduling For Radiant Systems In Buildings, Truong Nghiem, Madhur Behl, George Pappas, Rahul Mangharam Oct 2012

Green Scheduling For Radiant Systems In Buildings, Truong Nghiem, Madhur Behl, George Pappas, Rahul Mangharam

Rahul Mangharam

In this report we look at the problem of peak power reduction for buildings with electric radiant floor heating systems. Uncoordinated operation of a multi-zone radiant floor heating system can result in temporally correlated electricity demand surges or peaks in the building’s electricity consumption. As peak power prices are 200-400 times that of the nominal rate, this uncoordinated activity can result in high electricity costs and expensive system operation. We have previously presented green scheduling as an approach for reducing the aggregate peak power consumption in buildings while ensuring that indoor thermal comfort is always maintained. This report extends the …


Technique For Measurement Of Weld Resistance For Ac Resistance Spot Welding Via Instantaneous Phasor Measurement, Mian Mohsin Irshad Aug 2012

Technique For Measurement Of Weld Resistance For Ac Resistance Spot Welding Via Instantaneous Phasor Measurement, Mian Mohsin Irshad

Electronic Thesis and Dissertation Repository

The resistance measurement in the resistance spot welding (RSW), is an ongoing research topic. The high current flow during the welding process induces an electromagnetic field in the wires which are attached to the electrodes to measure tip voltage. This results an additional voltage drop which is proportional to the derivative of current. Also the presence of silicon controlled rectifier (SCR) in the welding power supply generates harmonics in both supply voltage and current. These issues together complicate the methods for resistance estimation.

A set of simultaneous linear equations is derived for the on-line measurement of dynamic resistance and induced …


Transient Stability Hierarchical Control In Multimachine Power Systems, A Rubbai, F. Eugenio Villaseca Jul 2012

Transient Stability Hierarchical Control In Multimachine Power Systems, A Rubbai, F. Eugenio Villaseca

F. Eugenio Villaseca

The authors present the optimal transient stability control problem in a hierarchical structure for multimachine power systems. The two-level structure retains the local closed-loop controls, thereby easing its implementation on existing systems. The formulation accounts for nonlinearities and interconnections, and the optimization of the system transient performance is obtained with less computational effort. Since the computations are distributed among the many local feedback subsystems, the storage and solution times are considerably less than those required by a single overall centralized controller. This advantage becomes much stronger as the system size increases. For illustration purposes, this technique was applied successfully to …


Back To The Future Of Green Powered Economies, Juan B. Moreno-Cruz, M. Scott Taylor Jul 2012

Back To The Future Of Green Powered Economies, Juan B. Moreno-Cruz, M. Scott Taylor

Juan B. Moreno-Cruz

The purpose of this paper is to introduce the concept of power density [Watts/m2] into economics. By introducing an explicit spatial structure into a simple general equilibrium model we are able to show how the power density of available energy resources determines the extent of energy exploitation, the density of urban agglomerations, and the peak level of income per capita. Using a simple Malthusian model to sort population across geographic space we demonstrate how the density of available energy supplies creates density in energy demands by agglomerating economic activity. We label this result the density-creates-density hypothesis and evaluate it using …


Switch Yard Operation In Thermal Power Plant(Katpp Jhalawar Rajasthan), Radhey Shyam Meena Er. Jul 2012

Switch Yard Operation In Thermal Power Plant(Katpp Jhalawar Rajasthan), Radhey Shyam Meena Er.

Radhey Shyam Meena

Switchyard Provides the facilities for switching ,protection & Control of electric power. To handle high Voltage power with proper Safety measures. To isolate the noises coming from the grid with true 50Hz power SWITCH YARD IS IMPORTANT PART IN THERMAL PLANT. IN KALISINDH THERMAL 400KV AND 220KV SWITCH YARD LOCATED.


A Proposed Control Solution For The Cal Poly Wind Energy Capture System, Kent R. Burnett Jun 2012

A Proposed Control Solution For The Cal Poly Wind Energy Capture System, Kent R. Burnett

Master's Theses

The focus of this thesis is to research, analyze, and design a reliable and economical control system for the Cal Poly Wind Energy Capture System (WECS). A dynamic permanent magnet generator model is adopted from [1] and [2] and combined with an existing wind turbine model to create a non-linear time varying model in MATLAB. The model is then used to analyze potentially harmful electrical disturbances, and to define safe operating limits for the WECS. An optimal operating point controller utilizing a PID speed loop is designed with combined optimization criteria and the final controller design …


Monitoring And Regression Based Modelling Of End Winding Vibration In Large Synchronous Generators., David Shally May 2012

Monitoring And Regression Based Modelling Of End Winding Vibration In Large Synchronous Generators., David Shally

Masters

This research project was set up to monitor, on an ongoing basis, the condition of the end windings and their support structures of a 288 MVA 2-pole synchronous generator with a known end winding vibration problem Excessive vibration at the end windings was caused by the natural frequencies of individual end bars (local) and of the entire end winding structure (global) being at or close to the magnetic forcing frequency of 100 Hz. Resonant vibration such as this has been a cause of major failures in machines of the same type in the past, resulting in significant down time ranging …


A Robust Decentralized Load Frequency Controller For Interconnected Power Systems, Lili Dong, Yao Zhang, Zhiqiang Gao May 2012

A Robust Decentralized Load Frequency Controller For Interconnected Power Systems, Lili Dong, Yao Zhang, Zhiqiang Gao

Electrical and Computer Engineering Faculty Publications

A novel design of a robust decentralized load frequency control (LFC) algorithm is proposed for an inter-connected three-area power system, for the purpose of regulating area control error (ACE) in the presence of system uncertainties and external disturbances. The design is based on the concept of active disturbance rejection control (ADRC). Estimating and mitigating the total effect of various uncertainties in real time, ADRC is particularly effective against a wide range of parameter variations, model uncertainties, and large disturbances. Furthermore, with only two tuning parameters, the controller provides a simple and easy-to-use solution to complex engineering problems in practice. Here, …


Improving Manufacturing Processes Through Energy Monitoring, Andrew Grzelak Apr 2012

Improving Manufacturing Processes Through Energy Monitoring, Andrew Grzelak

Purdue Polytechnic Masters Theses

Energy efficiency and sustainability are very popular topics in the current field of manufacturing. With the increase in use of automation technology as well as the recent growth in the area of energy management, there is much focus on the overall improvement of manufacturing processes. For this research a project was completed to create a system that could improve both process efficiency as well as decrease energy consumption. By taking a look at the machine level energy consumption of an automated piece of manufacturing equipment, by eliminating waste in process, both energy efficiency and operational efficiency can be improved.

Using …


Dynamic Modeling Of Solid Oxide Fuel Cell Stack Based On Local Linear Model Tree Algorithm, Hesamoddin Marzooghi, M. Raoofat, M. Dehghani, G. H. Elahi Mar 2012

Dynamic Modeling Of Solid Oxide Fuel Cell Stack Based On Local Linear Model Tree Algorithm, Hesamoddin Marzooghi, M. Raoofat, M. Dehghani, G. H. Elahi

Hesamoddin Marzooghi

This paper presents a dynamic model for Solid Oxide Fuel Cell (SOFC) stack using Local Linear Model Tree (LOLIMOT) algorithm which is useful for both dynamic and steady-state studies. Most of conventional SOFC models require a large number of parameters and factors, which are difficult to be determined or estimated. In this paper, a LOLIMOT-based model, which does not require the parameters of fuel cell, is proposed for each operation mode of SOFC. In these models, decision tree-based feature selection approach is exploited to select inputs of the LOLIMOT. The proposed models are trained in a short time and they …


Application Of Modern Control Theory For The Power-System Analysis And Control, Mulukutla S. Sarma, Earl D. Eyman Feb 2012

Application Of Modern Control Theory For The Power-System Analysis And Control, Mulukutla S. Sarma, Earl D. Eyman

Sarma Mulukutla

With the current rise in the demand of electrical energy, present-day power systems which are large and complex, will continue to grow both in size and complexity. Also, our dependence on electrical energy is so great that it is essential to have uninterrupted supply of electrical power within set limits of frequency and voltage levels, and that it becomes a dire necessity to develop methods for effective control and operation of power systems. Modern control theory concepts have been effectively used and will continue to be utilized for the power system analysis and control. This paper attempts in assessing the …


Polar Field Oriented Control With 3rd Harmonic Injection, Martin Todd Hess Feb 2012

Polar Field Oriented Control With 3rd Harmonic Injection, Martin Todd Hess

Master's Theses

Abstract

POLAR FIELD-ORIENTED CONTROL

with

3RD HARMONIC INJECTION

Martin Todd Hess

Field Oriented Control (FOC), also known as vector control, is a widely used and well documented method for controlling Permanent-Magnet Synchronous Motors (PMSM) and induction motors. Almost invariably the orientation of the stator and rotor (field) fluxes are described in rectangular coordinates. In this thesis we explore the practicality of using polar coordinates.

Third harmonic injection is also a well-known technique that allows full utilization of the bus (DC-link), thus allowing the motor to run to full base speed without the use of field weakening. This technique potentially …


Modeling And Simulation Of Z-Source Inverter, Suresh L Jan 2012

Modeling And Simulation Of Z-Source Inverter, Suresh L

suresh L

Z – source inverters have been recently proposed as an alternative power conversion concept as they have both voltage buck and boost capabilities. These inverters use a unique impedance network, coupled between the power source and converter circuit, to provide both voltage buck and boost properties, which cannot be achieved with conventional voltage source and current source inverters. To facilitate understanding of Z – source inverter, this paper presents a detailed analysis, showing design of impedance network, implementation of simple Boost control PWM technique and simulation of Z – source inverter for different values of modulation indices.


An Adaptive Utility Interactive Photovoltaic System Based On A Flexible Switch Matrix To Optimize Performance In Real-Time, Mahmoud Alahmad, Mohamed Amer Chaaban, Siu Kit Lau, Jonathan Shi, Jill Neal Jan 2012

An Adaptive Utility Interactive Photovoltaic System Based On A Flexible Switch Matrix To Optimize Performance In Real-Time, Mahmoud Alahmad, Mohamed Amer Chaaban, Siu Kit Lau, Jonathan Shi, Jill Neal

Durham School of Architectural Engineering and Construction: Faculty Publications

Reconfigurable architectures are of great interest to system designers to improve the system’s operation and efficiency. In this paper, we propose an adaptive utility interactive photovoltaic (PV) system based on a novel Flexible Switch array Matrix topology. This proposed system maximizes the generated power in real-time in response to operational conditions such as shading, soiling, mismatches, and module failure among others. The proposed system is a compromise in the utilization of power conditioning equipment to maximize energy capture and system efficiency. Simulation results demonstrate an average 13% improvement in efficiency when compared with the central inverter topology performance. A prototype …