Investigating Composite Action At Ultimate For Commercial Sandwich Panel Composite Connectors, Salam Al-Rubaye, Taylor J. Sorensen, Marc Maguire
Investigating Composite Action At Ultimate For Commercial Sandwich Panel Composite Connectors, Salam Al-Rubaye, Taylor J. Sorensen, Marc Maguire
Faculty Publications
To achieve full or partial-composite action in prestressed concrete sandwich panel walls, the engineer must obtain a percent composite action from a connector manufacturer, making some engineers uncomfortable. Engineers are dependent upon the recommendations given by the connector manufacturers to establish their designs. This project tested six full-scale sandwich panel walls to evaluate the percent composite action of various connectors and compare the results to those provided by the composite connector manufacturers. This study concluded that the reported degrees of composite action from each manufacturer are considered conservative in all instances for the connectors tested in this paper. Additionally, the …