Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 1 of 1
Full-Text Articles in Environmental Engineering
Optimizing Chlorine Disinfection By Chlorine Injection Location And Pipe Diameter Selection In A Water Distribution System, Margaret Neff
Optimizing Chlorine Disinfection By Chlorine Injection Location And Pipe Diameter Selection In A Water Distribution System, Margaret Neff
Dissertations, Master's Theses and Master's Reports
Due to a variety of factors chlorination is common water disinfectant for community-scale distribution systems. The town of Suyo, Peru was already equipped with a gravity fed water system and drip chlorinator which achieved 4-log inactivation of viruses throughout the town, however, it was not providing 3-log inactivation of giardia cysts at all points of the system.
This project used an EPANET model to determine and compare the potential benefits of changes which could be made to the pre-existing water system in Suyo.
The model was used to compare current operating conditions of the Suyo system, 1.5 mg/L chlorine addition …