Ocena Efektów Modernizacji Systemu Oczyszczania I Ewakuacji Spalin Na Wybranych Przykładach, Robert Oleniacz, Marcelina Groborz, Michał Ożóg Dec 2011

Ocena Efektów Modernizacji Systemu Oczyszczania I Ewakuacji Spalin Na Wybranych Przykładach, Robert Oleniacz, Marcelina Groborz, Michał Ożóg

Robert Oleniacz

The paper presents an assessment of changes in air emissions and impacts on air quality resulting from the modernization of flue gas cleaning and evacuation in two Polish coal-fired power plants. These modernizations were associated with the construction of flue gas desulphurisation systems and use for discharging desulphurized gases separate stacks with a height of 120 m. On the basis of analyzes and atmospheric dispersion modeling, it was found that the changes in the effective height of emitters (the apparent point of emission), due to additional reducing of flue gas volume in existing chimneys, caused that important ecological effects of …


Wpływ Zakładu Unieszkodliwiania Stałych Odpadów Komunalnych W Warszawie Na Jakość Powietrza, Robert Oleniacz, Jadwiga Antolak Nov 2010

Wpływ Zakładu Unieszkodliwiania Stałych Odpadów Komunalnych W Warszawie Na Jakość Powietrza, Robert Oleniacz, Jadwiga Antolak

Robert Oleniacz

The paper presents the results of air quality impact assessment carried out for the Municipal Solid Waste Disposal Plant in Warsaw. As part of the plant is working so far the only municipal solid waste incinerator in Poland. Following the evaluation, including data for the year 2008, it was found that it is a minor source of emissions to air and causes a slight air pollution. The highest maximum one-hour and annual average concentrations caused at ground level are many times lower than the respective reference (or permissible) values and background values for analyzed substances in the air. Increasing the …


Impact Of A Large Medical Waste Incinerator On Air Quality, Robert Oleniacz Dec 2009

Impact Of A Large Medical Waste Incinerator On Air Quality, Robert Oleniacz

Robert Oleniacz

In the paper, an assessment of the compliance with air emission limit values and the impact on air quality of one of the largest medical waste incinerators in Poland, with a total capacity of about 300 kg/h (two incineration lines) is presented. The assessment took the results of continuous and periodic measurements of emissions in the plant’s installation over a period of 12 months’ operation into account. For this period, a calculation was performed for the spread of air pollutants emitted by the two operating incineration lines. According to the analysis and calculations, the analysed medical waste incineration plant does …


Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch Dec 2007

Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch

Robert Oleniacz

Construction of the Municipal Solid Waste Incineration (MSWI) plant is considered optimal in the Programme of Management of Solid Waste in Krakow as well as in proposed scenarios of Municipal Waste Management. Evaluation of impact of the incineration plant with a capacity of 255000 tons per year on air quality in Krakow is presented in this work. The evaluation is based on assumption that air pollutant emissions from the incinerator will be at the highest allowed level resulting from emission limit values for waste incineration plants with operation time each of two planned lines 7500 hours per year. Calculation results …


Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch Oct 2007

Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch

Robert Oleniacz

The work presents air quality impact assessment for the planned Municipal Solid Waste Incineration (MSWI) plant in Krakow with a established capacity of 255000 tons per year. The evaluation is based on assumption that air pollutant emissions from the incinerator will be at the highest allowed level resulting from emission limit values for waste incineration plants with operation time each of two planned lines 7500 hours per year. Calculation results for the one of the considered localization of the MSWI plant in Krakow (district of Nowa Huta) support the thesis that building the incineration plant of this size will not …