Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Performance

Electrical and Computer Engineering

Faculty of Engineering University of Malaya

Articles 1 - 5 of 5

Full-Text Articles in Engineering

Single Phase Transformerless Inverter Topologies For Grid-Tied Photovoltaic System: A Review May 2015

Single Phase Transformerless Inverter Topologies For Grid-Tied Photovoltaic System: A Review

Faculty of Engineering University of Malaya

Grid-tied inverters are the key components of distributed generation system because of their function as an effective interface between renewable energy sources and utility. Recently, there has been an increasing interest in the use of transformerless inverter for low-voltage single-phase grid-tied photovoltaic (PV) system due to higher efficiency, lower cost, smaller size and weight when compared to the ones with transformer. However, the leakage current issues of transformerless inverter, which depends on the topology structure and modulation scheme, have to be addressed very carefully. This review focuses on the transformerless topologies, which are classified into three basic groups based on …


An Islanding Detection Strategy For Distribution Network Connected With Hybrid Dg Resources May 2015

An Islanding Detection Strategy For Distribution Network Connected With Hybrid Dg Resources

Faculty of Engineering University of Malaya

The exponential growth in electricity demand has driven the Distributed Generation (DG) technology a boost in the power system. The use of DG is beneficial to power utilities, DG owners', and end-users in terms of reliability, power quality, and economics. However, to fully utilize the benefits of DGs, some technical issues need to be addressed. Islanding condition is one of the most important issue in this context. Until now, several islanding detection techniques have been proposed for detecting the islanding condition. This paper presents a brief overview of existing islanding detection techniques with their relative merits and demerits. Apart from …


A Distributed Particle Filtering Approach For Multiple Acoustic Source Tracking Using An Acoustic Vector Sensor Network Mar 2015

A Distributed Particle Filtering Approach For Multiple Acoustic Source Tracking Using An Acoustic Vector Sensor Network

Faculty of Engineering University of Malaya

Different centralized approaches such as least-squares (LS) and particle filtering (PF) algorithms have been developed to localize an acoustic source by using a distributed acoustic vector sensor (AVS) array. However, such algorithms are either not applicable for multiple sources or rely heavily on sensor-processor communication. In this paper, a distributed unscented PF (DUPF) approach is proposed for multiple acoustic source tracking. At each distributed AVS node, the first-order and the second-order statistics of the local state are estimated by using an unscented information filter (UIF) based PF. The UIF is employed to approximate the optimum importance function due to its …


Zigbee-Based Data Acquisition System For Online Monitoring Of Grid-Connected Photovoltaic System Feb 2015

Zigbee-Based Data Acquisition System For Online Monitoring Of Grid-Connected Photovoltaic System

Faculty of Engineering University of Malaya

For grid-connected photovoltaic (PV) system, monitoring is considered as a crucial aspect for observing the stability and performance of the system. The simplest method is to have the data collected and transmitted across data cables. Due to the cost and technical limitations of the data cable, the monitoring station needs to be located reasonably close to the monitored plant. Apart being inconvenient, the use of data cable often adds capital and maintenance cost to the system. In this research project, a Zigbee-based wireless monitoring system is developed for online monitoring of a grid-connected photovoltaic system. Parameters like temperature, irradiation, PV …


Semi-Z-Source Inverter Topology For Grid-Connected Photovoltaic System Jan 2015

Semi-Z-Source Inverter Topology For Grid-Connected Photovoltaic System

Faculty of Engineering University of Malaya

Transformer-less inverters are necessary parts for grid-connected renewable energy resources. Owing to its cost effectiveness, downsize and less weight, great attention has been paid to these inverters development. With these aforementioned advantages, these inverters have limitations like the flow of leakage current through photovoltaic arrays, high total harmonic distortion (THD) at inverter's output and DC current injection to the grid. This study presents coupled inductor-based single-phase transformer-less semi-Z-source inverter topology to lessen those limitations. Since the DC input and AC output voltage share a common ground, the presented inverter system is categorised under doubly grounded topologies. For the purpose of …