Open Access. Powered by Scholars. Published by Universities.®

Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 10 of 10

Full-Text Articles in Engineering

Blood Glucose Predictor, Jessica Patterson Dec 2019

Blood Glucose Predictor, Jessica Patterson

Electrical Engineering

For my senior project, I perform data analysis using statistical methods to determine body metrics that correlate with blood glucose levels. Working with Dr. Tina Smilkstein, I take repeat measurements from 6 different volunteers to establish trends in bodily metric data. The data taken includes weight, body fat, pulse rate, VO2, blood glucose, blood pressure, hours slept, and quality of sleep. Using these values, I use the program MiniTab to view results.

A few examples of correlations with blood glucose found in this project are:

  • Systolic blood pressure for females had a regression line of 124.0 -0.3366*Blood Pressure. This indicates …


Single-Cell Impedance Spectroscopy, David Paul Lange Dec 2019

Single-Cell Impedance Spectroscopy, David Paul Lange

Master's Theses

Impedance spectroscopy (IS) is an important tool for cell detection and characterization in medical and food safety applications. In this thesis, the Cal Poly Biofluidics Lab’s impedance spectroscopy system was re-evaluated and optimized for single-cell impedance spectroscopy. To evaluate the IS system, an impedance spectroscopy bioMEMS chip was fabricated in the Cal Poly Microfabcrication lab, software was developed to run IS experiments, and studies were run to validate the system. To explore IS optimization, Maxwell’s mixture theorem and the Schwartz-Christoffel transform were used to calculate an analytic impedance solution to the co-planar electrode system,a novel volume fraction to account for …


Cooking Hand Multi-Tool, Amanda D. Meares, Amy H. Wilson, Ethan G. Littlejohn, Duania A. Evans Jun 2019

Cooking Hand Multi-Tool, Amanda D. Meares, Amy H. Wilson, Ethan G. Littlejohn, Duania A. Evans

Biomedical Engineering

The purpose of this project was to devise a solution for Jorge Segura, a US Marine who was wounded in Afghanistan and had to have his non-dominant arm amputated above the elbow. His current prosthetic attachments are not suited to cooking tasks, so he needed a way to cook more effectively with either prosthetic attachments or accessibility devices. The main tasks that he needed help with was holding down food on cutting boards and stabilizing pots, pans, and bowls especially when stirring. After background research, exploring commercially available devices, and talking with our challenger, our solution was to design three …


A 3-Dimensional In Silico Test Bed For Radiofrequency Ablation Catheter Design Evaluation And Optimization, Carolyn Teng Jun 2019

A 3-Dimensional In Silico Test Bed For Radiofrequency Ablation Catheter Design Evaluation And Optimization, Carolyn Teng

Master's Theses

Atrial fibrillation (AF) is the disordered activation of the atrial myocardium, which is a major cause of stroke. Currently, the most effective, minimally traumatic treatment for AF is percutaneous catheter ablation to isolate arrhythmogenic areas from the rest of the atrium. The standard in vitro evaluation of ablation catheters through lesion studies is a resource intensive effort due to tissue variability and visual measurement methods, necessitating large sample sizes and multiple prototype builds. A computational test bed for ablation catheter evaluation was built in SolidWorks® using the morphology and dimensions of the left atrium adjacent structures. From this geometry, the …


Concussion Indication Device, Taylor O'Donoghue, Isabel Jellen, Eric Shechter Mar 2019

Concussion Indication Device, Taylor O'Donoghue, Isabel Jellen, Eric Shechter

Biomedical Engineering

In this document we summarize our intent to design and manufacture a device that will be used in conjunction with a football helmet, will detect impact forces to the head, and notify the user to seek out further medical attention when subjected to forces large enough to cause concussions. We describe the large market including all levels of football players and the need for improved technology that will not only be effective in elucidating risks but encouraging players to use the device over the alternatives. To design the device, we have researched the problem of concussions in football and have …


Slit Lamp Ophthalmoscope Redesign, Michael Hostetler, Austin Mattmiller, Alexis Brewer Mar 2019

Slit Lamp Ophthalmoscope Redesign, Michael Hostetler, Austin Mattmiller, Alexis Brewer

Biomedical Engineering

The slit lamp ophthalmoscope is used by ophthalmologists for diagnosis of pathologies in the eye. The device is used for identifying ocular diseases or indications of other possible systemic diseases to treat them before the diseases progress. Redesign of the ergonomics and adjustment mechanisms of the slit lamp ophthalmoscope will attempt to improve the compatibility of the device across a greater variety of patients. The wider headrest tower of 12.75 inches, the wider table cutout of 12 inches, and the 12 inches of extension of the headrest tower creates a better ergonomic fit for the patient and doctor. The wider …


Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler Mar 2019

Development Of A Myoelectric Detection Circuit Platform For Computer Interface Applications, Nickolas Andrew Butler

Master's Theses

Personal computers and portable electronics continue to rapidly advance and integrate into our lives as tools that facilitate efficient communication and interaction with the outside world. Now with a multitude of different devices available, personal computers are accessible to a wider audience than ever before. To continue to expand and reach new users, novel user interface technologies have been developed, such as touch input and gyroscopic motion, in which enhanced control fidelity can be achieved. For users with limited-to-no use of their hands, or for those who seek additional means to intuitively use and command a computer, novel sensory systems …


Ideomotion Gait Training Thigh Prompt, Kristin Schmidt, Elizabeth Peterson, Dalton Jennings Mar 2019

Ideomotion Gait Training Thigh Prompt, Kristin Schmidt, Elizabeth Peterson, Dalton Jennings

Biomedical Engineering

This document serves as our project report at its completion for developing thigh prompts to be used with the LiftWalker. In this document we outline our project from its beginning to end. We describe our process from understanding the background and our customer requirements, transforming these customer requirements into engineering specifications, performing the stage gate process, developing and evolving the design, testing the design, and finally drawing conclusions and making recommendations for the future.


Foot Support Taping Device For Off-Loading Wounds, Andres Fojaco Gomez, Mikaela Williams, Josh Pelegrin Mar 2019

Foot Support Taping Device For Off-Loading Wounds, Andres Fojaco Gomez, Mikaela Williams, Josh Pelegrin

Biomedical Engineering

No abstract provided.


Accelerated Wear Reactor Testing, Tristan Frisella, Daniel Alanis, Kian Ashoubi Mar 2019

Accelerated Wear Reactor Testing, Tristan Frisella, Daniel Alanis, Kian Ashoubi

Biomedical Engineering

Carbon dioxide accounts for a large amount of global greenhouse gases released into the environment. Because plastic degradation emits carbon dioxide, there has been interest to investigate how much carbon dioxide various plastics generate as they degrade. We have been tasked to create a dehumidifier and carbon dioxide sensor assembly for an accelerated wear testing apparatus that degrades plastic. Several products and literature currently exist that share similarity with our assembly but have not been manufactured to achieve the same combination of measurements we are expecting of our accelerated wear testing device. The following report shall introduce these products and …