Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- University of Nebraska - Lincoln (4546)
- Missouri University of Science and Technology (2226)
- California Polytechnic State University, San Luis Obispo (1643)
- Brigham Young University (1343)
- University of Kentucky (1054)
-
- University of Central Florida (1009)
- University of Texas at Arlington (962)
- Michigan Technological University (839)
- Old Dominion University (811)
- University of Texas Rio Grande Valley (657)
- Purdue University (619)
- University of South Carolina (604)
- New Jersey Institute of Technology (570)
- Utah State University (514)
- Universitas Indonesia (508)
- Louisiana State University (452)
- National Taiwan Ocean University (445)
- University of Nevada, Las Vegas (396)
- University of Alabama at Birmingham (381)
- Washington University in St. Louis (376)
- Clemson University (371)
- University of Texas at El Paso (346)
- Portland State University (332)
- The University of Akron (331)
- Cleveland State University (321)
- Wright State University (300)
- University of Arkansas, Fayetteville (299)
- Central Washington University (262)
- Marquette University (254)
- Embry-Riddle Aeronautical University (235)
- Keyword
-
- Engineering (593)
- ASME (395)
- Conference (378)
- ECTC (378)
- Proceedings (378)
-
- Additive manufacturing (333)
- Mechanical Engineering (306)
- Applied sciences (297)
- Buildings (286)
- Optimization (260)
- Gas (253)
- And Energy; Structural Materials; Sustainability (248)
- Energy Systems; Environmental Indicators and Impact Assessment; Environmental Monitoring; Mining Engineering; Oil (248)
- Additive Manufacturing (221)
- Simulation (216)
- CFD (212)
- Design (202)
- Manufacturing (202)
- Department of Mechanical and Materials Engineering (180)
- Heat transfer (172)
- Robotics (166)
- Department of Mechanical Engineering-Engineering Mechanics (151)
- Composites (150)
- Finite element analysis (134)
- Combustion (133)
- Computational fluid dynamics (131)
- Machine learning (131)
- Modeling (131)
- Microstructure (130)
- 3D printing (128)
- Publication Year
- Publication
-
- Nebraska Tractor Tests (3397)
- Theses and Dissertations (1702)
- Mechanical and Aerospace Engineering Faculty Research & Creative Works (1144)
- Mechanical Engineering (972)
- Faculty Publications (763)
-
- Masters Theses (699)
- Mechanical and Aerospace Engineering Theses - Archive (677)
- Electronic Theses and Dissertations (655)
- Department of Mechanical and Materials Engineering: Faculty Publications (620)
- Mechanical Engineering Faculty Publications (618)
- World of Coal Ash Proceedings (579)
- Mechanical & Aerospace Engineering Theses & Dissertations (551)
- FSEC Energy Research Center® (516)
- Theses (467)
- Journal of Marine Science and Technology–Taiwan (445)
- Makara Journal of Technology (440)
- Early Career Technical Journal (ECTJ) (378)
- Open Access Theses & Dissertations (332)
- Master's Theses (315)
- Dissertations, Master's Theses and Master's Reports (277)
- Industrial and Manufacturing Engineering (273)
- Mechanical and Aerospace Engineering Dissertations - Archive (266)
- Dissertations (261)
- Williams Honors College, Honors Research Projects (260)
- LSU Master's Theses (255)
- Doctoral Dissertations (253)
- Mechanical Engineering Design Project Class (242)
- All Undergraduate Projects (226)
- Theses and Dissertations--Mechanical and Aerospace Engineering (221)
- Mechanical Engineering ETDs (202)
- Publication Type
Articles 27451 - 27480 of 30042
Full-Text Articles in Engineering
Test 1517: Ford Tw-35 Diesel 16-Speed, Nebraska Tractor Test Lab
Test 1517: Ford Tw-35 Diesel 16-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Test 1514: Ford Tw-5 And 8530 Diesel 16-Speed, Nebraska Tractor Test Lab
Test 1514: Ford Tw-5 And 8530 Diesel 16-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Test 1515: Ford Tw-15 Diesel 16-Speed, Nebraska Tractor Test Lab
Test 1515: Ford Tw-15 Diesel 16-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Test 1516: Ford Tw-25 And 8730 Diesel 16-Speed, Nebraska Tractor Test Lab
Test 1516: Ford Tw-25 And 8730 Diesel 16-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Test 1511: Massey-Ferguson 3505 Diesel 16-Speed, Nebraska Tractor Test Lab
Test 1511: Massey-Ferguson 3505 Diesel 16-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Test 1512: Massey-Ferguson 3525 Diesel 16-Speed, Nebraska Tractor Test Lab
Test 1512: Massey-Ferguson 3525 Diesel 16-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Test 1513: Massey-Ferguson 3545 Diesel 16-Speed, Nebraska Tractor Test Lab
Test 1513: Massey-Ferguson 3545 Diesel 16-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Flake Aligner Including Baffles Supported On Continuously Moving Conveyor, Anders E. Lund, Gordon P. Krueger, Lynn B. Sandberg, Roy D. Adams
Flake Aligner Including Baffles Supported On Continuously Moving Conveyor, Anders E. Lund, Gordon P. Krueger, Lynn B. Sandberg, Roy D. Adams
Michigan Tech Patents
Apparatus for forming a continuous elongated loosely felted mat of thin elongated wood flakes with the flakes being aligned in mutually parallel interleaved relation. The apparatus includes a plurality of belts positioned in adjacent side-by-side relation and for continuous movement so as to define a supporting surface for the mat. A plurality of sets of thin planar baffle plates are provided, each set including a plurality of thin planar baffle plates supported in coplanar alignment and in edge-to-edge adjacent relation. The baffle plates are positioned between a hopper for depositing wood flakes and the supporting surface and function to align …
Fundy Tidal Power Development : Preliminary Evaluation Of Its Environmental Consequences To The Resources Of The State Of Maine, Bigelow Laboratory For Ocean Sciences
Fundy Tidal Power Development : Preliminary Evaluation Of Its Environmental Consequences To The Resources Of The State Of Maine, Bigelow Laboratory For Ocean Sciences
Maine Collection
Fundy Tidal Power Development : Preliminary Evaluation of Its Environmental Consequences to the Resources of the State of Maine
A Report to the Maine State Planning Office by the Bigelow Laboratory for Ocean Sciences, April, 1984.
"Technical Report No. 35 - Bigelow Laboratory for Ocean Sciences, West Boothbay Harbor, Maine - A Division of Northeastern Research Foundation, Inc."
Contents: Executive Summary / Introduction / Methods / Physical and Biological Consequences / Socio-Economic Consequences / Research Needs / Bibliography / Appendix I. Written Comments on Greenberg Model
Comparative Heat Load Analysis For A Direct Gain Passive Solar Building, Hong Hu
Comparative Heat Load Analysis For A Direct Gain Passive Solar Building, Hong Hu
Mechanical & Aerospace Engineering Theses & Dissertations
A newly erected University Police Safety Building on the campus was constructed with passive solar design features. The slab-on-grade brick building has 3081 square feet of conditioned space, an ample south-facing solar aperture with clerestory and an air-to-air heat pump system. A comparative winter heat load assessment has been made in order to determine the fraction of the heat load which can be met by the winter sun (Norfolk, VA 37°N Latitude), and more importantly to probe differences which result when various heat load estimating methods are employed. Techniques employed included the degree day method·, bin method with and with …
The Development Of A Microprocessor Controlled Linearly Actuated Valve Assembly, Raymond H. Wall
The Development Of A Microprocessor Controlled Linearly Actuated Valve Assembly, Raymond H. Wall
Mechanical & Aerospace Engineering Theses & Dissertations
The development of a proportional fluid control valve/assembly is presented. This electro-mechanical system is needed for space applications to replace the current proportional flow controllers that use bulky hydraulic or pneumatic actuation systems. The flow is controlled by a microprocessor system that monitors the control parameters of upstream pressure and requested volumetric flow rate. The microprocessor achieves the ·proper valve stem displacement by means of a digital linear actuator. A linear displacement sensor is used to measure the valve stem position. 'Ibis displacement is monitored by the microprocessor system as a feedback signal to close the control loop. With an …
Shape Optimization For Elastic Hollow Bars In Torsion, Jahau Lewis Chen
Shape Optimization For Elastic Hollow Bars In Torsion, Jahau Lewis Chen
Mechanical & Aerospace Engineering Theses & Dissertations
The problem of finding optimal cross-sectional shapes of elastic hollow bars in torsion is formulated and solved numerically. A variational formulation for the state equation is presented, and the material derivative of continuum mechanics is used for the shape design sensitivity analysis. Performance criteria include the bending stiffness, the torsional rigidity, and the weight of the bar. The existence of a keyway, an example of geometric irregularity, can be considered as well. The material can be either isotropic or anisotropic. The finite element method is used for the numerical solution of the variational state equation and is integrated into an …
Design Of A Combustion System Simulating Waste Heat Recovery From Diesel Engine Exhaust Gases, Nikolaos Papadopoulos
Design Of A Combustion System Simulating Waste Heat Recovery From Diesel Engine Exhaust Gases, Nikolaos Papadopoulos
Mechanical & Aerospace Engineering Theses & Dissertations
A forced-draft laboratory combustion system simulating diesel engine exhaust gas volume flow rate and temperature conditions for waste energy recovery is analyzed and discussed. The system consists of a fan which supplies the air. The slightly compressed air is then ducted through a combustor where it is heated, and then to an air-quencher where it is cooled to a desired temperature. Finally, the air is sent through a heat exchanger, after a diffuser process, for waste heat recovery.
A gas dynamic analysis has been performed for each component part as well as a parametric study via a computer program in …
Test 1508: Ford 1910 (12x4) Synchro Diesel 12-Speed, Nebraska Tractor Test Lab
Test 1508: Ford 1910 (12x4) Synchro Diesel 12-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Test 1510: Ford 2110 (12x4) Synchro Diesel, Nebraska Tractor Test Lab
Test 1510: Ford 2110 (12x4) Synchro Diesel, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Test 1509: Ford 2110 (12x4) Manual Diesel 12-Speed, Nebraska Tractor Test Lab
Test 1509: Ford 2110 (12x4) Manual Diesel 12-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Test 1507: Ford 1910 (12x4) Manual Diesel 12-Speed, Nebraska Tractor Test Lab
Test 1507: Ford 1910 (12x4) Manual Diesel 12-Speed, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Solar Distillation Of Water, Florida Solar Energy Center, Ross Mccluney
Solar Distillation Of Water, Florida Solar Energy Center, Ross Mccluney
FSEC Energy Research Center®
The Florida Solar Energy Center receives frequent requests for information about solar distillation for purifying water. Distillations is one of many processes available for water purification, and sunlight is one of several forms of heat energy that can be used to power that process. Sunlight has the advantage of zero fuel cost but it requires more space (for its collection) and generally more costly equipment.
To dispel a common belief, it is not necessary to boil water to distill it. Simply elevating its temperature, short of boiling, will adequately increase the evaporation rate. In fact, although vigorous boiling hastens the …
Analysis Of Deflection Temperature Under Load, Anand M. Jagani
Analysis Of Deflection Temperature Under Load, Anand M. Jagani
Theses
Deflection Temperature Under Load (DTUL) is an experimental value commonly used by designers to characterize a plastic in a high temperature environment. This value is currently measured by a standard test procedure specified by the ASTM D-648. A theoretical analysis of this test was made and computer programs were developed to calculate the Deflection Temperaure of Plastics Under Load based upon temperature dependent flexural modulus data and temperature dependent thermal properties of the plastics of interest. The results obtained from the theoretical analysis agree closely with the experimental values found in the literature for two resins. An analysis of the …
Test 1532: Hesston 80-66dt And 80-66 Fiat Diesel 12-Speeds, Nebraska Tractor Test Lab
Test 1532: Hesston 80-66dt And 80-66 Fiat Diesel 12-Speeds, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE General Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure. The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Retention Of Gasification-Combustion Products By Corn, S. W. Sizemore, Otto J. Loewer, Joseph L. Taraba, I. J. Ross, G. M. White
Retention Of Gasification-Combustion Products By Corn, S. W. Sizemore, Otto J. Loewer, Joseph L. Taraba, I. J. Ross, G. M. White
Biosystems and Agricultural Engineering Faculty Publications
Shelled corn was dried in layers of 5.1 cm (2 in.) 10.2 cm (4 in.), and 15.2 cm (6 in.) using air heated with the exhaust from a corn-cob fueled gasification-combustion updraft furnace. The drying air entering and leaving the grain layers was sampled for particulate content to determine the percentage of total particulates trapped by the grain during drying. It was determined that an average of 25% of the total particulates in the drying air were retained by the grain. The large majority of those particulates retained were found in the bottom 5.1 cm (2 in.) of the grain …
Generalized Root-Loci Theory For The Static Scherbius Drive, B. Lequesne, Aaron J. Miles
Generalized Root-Loci Theory For The Static Scherbius Drive, B. Lequesne, Aaron J. Miles
Mechanical and Aerospace Engineering Faculty Research & Creative Works
Generalized root-loci techniques, developed in the mid 70's for squirrel cage motors, have been extended in the static Scherbius configuration to wound rotor, slip energy, recovery systems. This arrangement is now applied to large power drives in the 0.5 to 50 MW range. In this paper, general results applicable to all machines are presented for the open-loop control scheme, but only the sub synchronous mode of operation in which a voltage source type inverter is used is addressed. Copyright © 1984 by The Institute of Electrical and Electronics Engineers, Inc.
Nebraska Summary S021: Zetor 16145, Nebraska Tractor Test Lab
Nebraska Summary S021: Zetor 16145, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …
Nebraska Summary S020: Zetor 12145, Nebraska Tractor Test Lab
Nebraska Summary S020: Zetor 12145, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …
Nebraska Summary S019: Zetor 12111, Nebraska Tractor Test Lab
Nebraska Summary S019: Zetor 12111, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …
Nebraska Summary S018: Zetor 10145, Nebraska Tractor Test Lab
Nebraska Summary S018: Zetor 10145, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …
Nebraska Summary S113: Agco Allis 7650, Nebraska Tractor Test Lab
Nebraska Summary S113: Agco Allis 7650, Nebraska Tractor Test Lab
Nebraska Tractor Tests
ABOUT THE TEST REPORT AND USE OF THE DATA The test data contained in this report are a tabulation of the results of a series of tests. Due to the restricted format of these pages, only a limited amount of data and not all of the tractor specifications are included. The full OECD report contains usually about 30 pages of data and specifications. The test data were obtained for each tractor under similar conditions and therefore, provide a means of comparison of performance based on a limited set of reported data. EXPLANATION OF THE TEST PROCEDURES Purpose The purpose of …
Generalized Root-Loci Theory For The Static Scherbius Drive, B. Lequesne, Aaron J. Miles
Generalized Root-Loci Theory For The Static Scherbius Drive, B. Lequesne, Aaron J. Miles
Mechanical and Aerospace Engineering Faculty Research & Creative Works
No abstract provided.
Test 1536: Ford Tw-15 Fwd Diesel Also Ford 8630 Diesel 16-Speeds, Nebraska Tractor Test Lab
Test 1536: Ford Tw-15 Fwd Diesel Also Ford 8630 Diesel 16-Speeds, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE
General
Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure.
The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …
Test 1538: Massey-Ferguson 670 Diesel And Massy-Ferguson 270 Multipower Diesel 12-Speeds, Nebraska Tractor Test Lab
Test 1538: Massey-Ferguson 670 Diesel And Massy-Ferguson 270 Multipower Diesel 12-Speeds, Nebraska Tractor Test Lab
Nebraska Tractor Tests
EXPLANATION OF THE TEST PROCEDURE
General
Tractors are tested at the University of Nebraska according to the Agricultural Tractor Test Code approved by the American Society of Agricultural Engineers and the Society of Automotive Engineers or official Nebraska test procedure.
The manufacturer selects the tractor to be tested and certifies that it is a stock model. Each tractor is equipped with the common power consuming accessories such as power steering, power lift pump, generator, etc., if available. Power consuming accessories may be disconnected only when the means for disconnecting can be reached from the operating station. An official representative of …