Feasibility Of Cathodic Protection In Grouted Post Tensioned Tendons - Exploratory Model Calculations, Jacob Dharma Bumgardner Nov 2015

Feasibility Of Cathodic Protection In Grouted Post Tensioned Tendons - Exploratory Model Calculations, Jacob Dharma Bumgardner

USF Tampa Graduate Theses and Dissertations

Recent corrosion related failures of grouted post tensioned tendons, even after the introduction of improved grouts, have led to renewed interest in supplemental or backup means of corrosion control for these systems. A finite element model is presented to explore feasibility of impressed current cathodic protection of strand in grouted tendons. The model examines polarization evolution as function of service time and includes consideration of anode placement and size, grout porosity, pore water alkalinity, electrochemical species diffusivity and applied voltage on the polarization efficacy and durability of such a system. The exploratory model projections suggested that, within the context of …


Metallic Encapsulation For High Temperature (>500 °C) Thermal Energy Storage Applications, Abhinav Bhardwaj Jan 2015

Metallic Encapsulation For High Temperature (>500 °C) Thermal Energy Storage Applications, Abhinav Bhardwaj

USF Tampa Graduate Theses and Dissertations

Deployment of high temperature (>500 °C) thermal energy storage in solar power plants will make solar power more cost competitive and pave the way towards a sustainable future. In this research, a unique metallic encapsulation has been presented for thermal energy storage at high temperatures, capable of operation in aerobic conditions. This goal was achieved by employing low cost materials like carbon steel. The research work presents the unique encapsulation procedure adopted, as well as various coatings evaluated and optimized for corrosion protection. Experimental testing favored the use of 150 μm of nickel on carbon steel for corrosion protection …


Kelvin Probe Electrode For Contactless Potential Measurement On Concrete-Properties And Applications, Michael Thomas Walsh Jan 2013

Kelvin Probe Electrode For Contactless Potential Measurement On Concrete-Properties And Applications, Michael Thomas Walsh

USF Tampa Graduate Theses and Dissertations

The practical feasibility of using a Kelvin Probe as a novel reference electrode in the measurement of both potential and polarization pulse response of reinforcing steel in concrete is demonstrated. Potential values measured using a KP reflect greater stability and repeatability than can typically be attained with conventional reference electrodes. Duplicate reinforced concrete beam test specimens with well-differentiated centrally corroding rebar segments were analyzed using both the Kelvin Probe (KP) and a conventional Saturated Calomel Electrode (SCE). Potential profile maps were developed using potential values recorded under static conditions with both the SCE and the KP. Nominal polarization resistance was …


Oxygen Diffusion Characterization Of Frp Composites Used In Concrete Repair And Rehabilitation, Chandra K. Khoe Jan 2011

Oxygen Diffusion Characterization Of Frp Composites Used In Concrete Repair And Rehabilitation, Chandra K. Khoe

USF Tampa Graduate Theses and Dissertations

Many independent studies have conclusively demonstrated that fiber reinforced polymers (FRP) slow down chloride-induced corrosion of steel in concrete. The mechanism for this slow down is not well understood but it has been hypothesized that FRP serves as a barrier to the ingress of chloride, moisture, and oxygen that sustain electrochemical corrosion of steel.

This dissertation presents results from an experimental study that determined the oxygen permeation rates of materials used in infrastructure repair. In the study, the oxygen permeation constants for epoxy, carbon and glass fiber laminates, concrete, epoxy-concrete and FRP-concrete systems were determined and a method developed to …