Open Access. Powered by Scholars. Published by Universities.®

Environmental Design Commons

Open Access. Powered by Scholars. Published by Universities.®

Construction Engineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 151 - 180 of 287

Full-Text Articles in Environmental Design

Infrared Thermography For Weld Inspection: Feasibility And Application, Sattar Dorafshan, Marc Maguire, William Collins Jan 2018

Infrared Thermography For Weld Inspection: Feasibility And Application, Sattar Dorafshan, Marc Maguire, William Collins

Durham School of Architectural Engineering and Construction: Faculty Publications

Traditional ultrasonic testing (UT) techniques have been widely used to detect surface and sub-surface defects of welds. UT inspection is a contact method which burdens the manufacturer by storing hot specimens for inspection when the material is cool. Additionally, UT is only valid for 5 mm specimens or thicker and requires a highly skilled operator to perform the inspections and interpret the signals. Infrared thermography (IRT) has the potential to be implemented for weld inspections due to its non-contact nature. In this study, the feasibility of using IRT to overcome the limitations of UT inspection is investigated to detect inclusion, …


Hvac System Remote Monitoring And Diagnosis Of Refrigerant Line Obstruction, Fadi M. Alsaleem Jan 2018

Hvac System Remote Monitoring And Diagnosis Of Refrigerant Line Obstruction, Fadi M. Alsaleem

Durham School of Architectural Engineering and Construction: Faculty Publications

A heating, ventilation, and air conditioning (HVAC) system of a building includes a refrigerant loop. A monitoring system for the HVAC system includes a monitoring device installed at the building. The monitoring device is configured to measure a first temperature of refrigerant in a refrigerant line located between a filter - drier of the refrigerant loop and an expansion valve of the refrigerant loop. The monitoring system includes a monitoring server, located remotely from the building. The monitoring server is con figured to receive the first temperature and, in response to the first temperature being less than a threshold, generate …


Bridge Build, Andrew Little Nov 2017

Bridge Build, Andrew Little

Student Scholarship

Bridge build design that includes not only a building process, but a research paper to make the best build possible as well.


Gas Collection, Haorong Li, Yanshun Yu, Daihong Yu Jun 2017

Gas Collection, Haorong Li, Yanshun Yu, Daihong Yu

Durham School of Architectural Engineering and Construction: Faculty Publications

A system includes a vessel configured to couple with a gas source for drawing gas into the vessel. The vessel is also configured to receive liquid. The system includes an over flow port in fluid communication with the environment external to the vessel. The overflow port is configured to separate gas within the vessel from the external environment. The system also includes an overflow conduit having an end within the overflow port so that when gas pressure within the vessel increases, liquid is received by the over flow conduit. Another system includes a tank defining an air space for receiving …


Offshore R+D Facility, Philip A. Marble May 2017

Offshore R+D Facility, Philip A. Marble

Bachelor of Architecture Theses - 5th Year

Design a Research + Development facility that merges with a functional Oil Rig. This center will house both a Marine Research Center and Oil rig Research + Development center. Both of these facilities will be in a separate structure than the Oil Rig but will have a connection back to the Living Quarter.


How Tonality And Loudness Of Noise Relate To Annoyance And Task Performance” Noise Control Eng. J. 65(2), 71-82., Joonhee Lee, Jennifer M. Francis, Lily M. Wang Apr 2017

How Tonality And Loudness Of Noise Relate To Annoyance And Task Performance” Noise Control Eng. J. 65(2), 71-82., Joonhee Lee, Jennifer M. Francis, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

Audible tones in noise generated by building mechanical equipment can be a leading cause of complaints from occupants. A number of metrics have been developed to quantify prominence of a tone, but previous work has shown that the impact of a certain tonality appears to vary with the level of the broadband noise signal. More work on how tonal signals of varying tonality, tone frequency and broadband noise levels relate to annoyance and task performance is needed. This paper investigates such relationships between current noise metrics, annoyance and task performance under assorted tonal noise conditions through subjective testing. Participants rated …


Clothedral, Jacob T. Holmes, Andres Munoz, Sam Tenreiro Theis, Marta Blachowicz Mar 2017

Clothedral, Jacob T. Holmes, Andres Munoz, Sam Tenreiro Theis, Marta Blachowicz

Architectural Engineering

No abstract provided.


Bau, January 17-21, Munich, Jim Roche Feb 2017

Bau, January 17-21, Munich, Jim Roche

Other resources

This bi-annual five-day event is one of the

leading and biggest trade fares of architecture,

materials, building systems and craft skills in

the world. Held in the huge Messe München

Trade Fair Center in eastern Munich and

stretching over 17 gigantic halls each the size

of a football pitch, it offers a truly rich display of

the latest innovations in building technology.


Research On Control Methods Of Roof Radiant Cooling System, Yongbin Li, Zhaoyi Zhuang, Qiqi Zhu, Jian Song, Haipeng An Jan 2017

Research On Control Methods Of Roof Radiant Cooling System, Yongbin Li, Zhaoyi Zhuang, Qiqi Zhu, Jian Song, Haipeng An

Durham School of Architectural Engineering and Construction: Faculty Publications

Taking the capillary ceiling radiation air conditioning system in radiation cooling Laboratory of comprehensive experimental building in Shandong Jianzhu University as an example, research the two different control methods which are room temperature control and water temperature control. The roof cooling model was established by using TRNSYS simulation software, two typical summer days were selected to explore the stability of the room temperature and the supply and return water temperature, research the comfort of human body and system energy consumption under two control methods. The results show that the indoor temperature of the two control methods can be stable at …


Gas Generation, Haorong Li, Daihong Yu, Yanshun Yu Jan 2017

Gas Generation, Haorong Li, Daihong Yu, Yanshun Yu

Durham School of Architectural Engineering and Construction: Faculty Publications

A first system includes a feedstock load port and a feedstock discharge port. The first system also includes a tank configured to retain biomass feedstock for aerobic biodegradation. The first system further includes a mechanical ventilator in fluid communication with the tank. The mechanical ventilator is configured to supply air to facilitate the aerobic biodegradation of the biomass feedstock. The first system also includes an exhaust port configured to receive gas generated during the aerobic biodegradation. A second system includes a feedstock load port and a feedstock discharge port. The second system also includes a pressure vessel configured to retain …


Compact Facility For Testing Steady And Transient Thermal Performance Of Building Walls, Aimee Byrne, Gerard Byrne, Anthony Robinson Jan 2017

Compact Facility For Testing Steady And Transient Thermal Performance Of Building Walls, Aimee Byrne, Gerard Byrne, Anthony Robinson

Articles

Energy efficiency retrofit of buildings represents a key effort in reducing EU energy demand by 20% by 2020. However, predictions tend to overestimate savings by large percentages. The shortfall in savings can be attributed to incorrect predictive techniques, comfort takeback along with other behavioural and workmanship variables. Common predictive techniques related to heat loss tend to be based on the U-value of the building envelope. This paper presents the design of a more straightforward and compact version of the traditional Hot-Box apparatus (measures U-value) which instead determines the thermal resistance of samples of building envelope. U-value includes the need to …


Study On The Methods For Predicting The Performance Of A Hybrid Solar-Assisted Ground-Source Heat Pump System, Zhaoyi Zhuang, Qiqi Zhu, Jian Song, Xin Zhang, Haorong Li Jan 2017

Study On The Methods For Predicting The Performance Of A Hybrid Solar-Assisted Ground-Source Heat Pump System, Zhaoyi Zhuang, Qiqi Zhu, Jian Song, Xin Zhang, Haorong Li

Durham School of Architectural Engineering and Construction: Faculty Publications

It is critical to find suitable setting parameters for designing a hybrid solar-assisted ground-source heat pump system in the practical engineering application, but the heat pump performance is unpredictable after many years of operation. This paper used 2000 sets of performance data collected from solar-assisted GSHP systems that keep operating over 20 years to simulate long term used heat pump with a professional software called GeoStar. Adopted the classification and regression tree (CART) method, the design of solar energy collector areas can be predicted. The multi-linear regression is also utilized to predict average monthly per meter borehole heat exchange. Seasonal …


Research On The Cooling Characteristics In Building Interior Zones Using Displacement Ventilation System, Zhaoyi Zhuang, Yongbin Li, Qiqi Zhu, Jian Song, Haipeng An, Haorong Li Jan 2017

Research On The Cooling Characteristics In Building Interior Zones Using Displacement Ventilation System, Zhaoyi Zhuang, Yongbin Li, Qiqi Zhu, Jian Song, Haipeng An, Haorong Li

Durham School of Architectural Engineering and Construction: Faculty Publications

The outdoor low temperature fresh air can be used as a free cold source to eliminate waste heat for the building interior zones during the transition season and winter. This paper takes a project in Hunan as an example, and the project building interior zones is 25m×7m×3.9m(L×W×H). Using Fluent software to simulate the temperature field and velocity field both the interior and exterior zones of the engineering offices. The simulation results show that using the displacement ventilation system to take the outdoor air into inner rooms not only cooling but also improving the air quality and adding comfort. According to …


Performance And Energy Efficiency Analysis Of Data Center Cooling Plant By Using Lake Water Source, Li Ling, Quan Zhang, Liping Zeng Jan 2017

Performance And Energy Efficiency Analysis Of Data Center Cooling Plant By Using Lake Water Source, Li Ling, Quan Zhang, Liping Zeng

Durham School of Architectural Engineering and Construction: Faculty Publications

A cooling plant by using lake water source was proposed to cool the space in data centers. It combines free cooling technology and variable capacity technology to remove heat and reduce energy consumption effectively. In this paper, firstly, the control strategies for this cooling plant were proposed. Then, a detailed annual energy consumption model with considering the effect of the dynamic heat dissipation characteristics of servers, lake water temperature, outdoor weather conditions, and cooling plant thermal performance, will be established to evaluate the performance and energy efficiency of this cooling plant under different load factors. The results show the mode …


Hvac System Remote Monitoring And Diagnosis, Jeffrey N. Arensmeier, Gregg M. Hemmelgarn, Fadi M. Alsaleem, Priotomo Abiprojo Jan 2017

Hvac System Remote Monitoring And Diagnosis, Jeffrey N. Arensmeier, Gregg M. Hemmelgarn, Fadi M. Alsaleem, Priotomo Abiprojo

Durham School of Architectural Engineering and Construction: Faculty Publications

A monitoring system for a heating, ventilation, and air conditioning (HVAC) system of a building includes a monitoring device installed at the building, a monitoring server located remotely from the building, and a review server. The monitoring device measures an aggregate current Supplied to components of the HVAC system and transmits current data based on the measured aggregate current. The monitoring server receives the transmitted current data and, based on the received current data, assesses whether failures have occurred in first and second components of the HVAC components. The monitoring server generates a first advisory in response to determining that …


Project Impact: A Case Study Of Developing A Manufactured Construction Workforce Through Contextualized Training, Arefeh Mohammadi, Kevin R. Grosskopf Jan 2017

Project Impact: A Case Study Of Developing A Manufactured Construction Workforce Through Contextualized Training, Arefeh Mohammadi, Kevin R. Grosskopf

Durham School of Architectural Engineering and Construction: Faculty Publications

With a looming shortage of skilled craft workers forecast to exceed 2 million by 2017, prefabrication may become a necessity for many U.S. contractors attempting to remain competitive with a smaller, lower-skilled workforce. Building components manufactured in a controlled, offsite environment have proven to reduce time, cost and site logistics while improving productivity, quality, safety and sustainability. However, entry-level workers, including more than 765,000 recession displaced manufacturing workers, often lack the basic skills necessary to retrain for jobs in manufactured construction. As a result, a $ 6.3M U.S. Department of Labor grant was awarded to an institutional consortium to develop …


A Case Study Of Upper-Room Uvgi In Densely-Occupied Elementary Classrooms By Real-Time Fluorescent Bioaerosol Measurements, Chunxiao Su, Josephine Lau, Fang Yu Jan 2017

A Case Study Of Upper-Room Uvgi In Densely-Occupied Elementary Classrooms By Real-Time Fluorescent Bioaerosol Measurements, Chunxiao Su, Josephine Lau, Fang Yu

Durham School of Architectural Engineering and Construction: Faculty Publications

Recently, the requirement to continuously collect bioaerosol samples using shorter response times has called for the use of real-time detection. The decreased cost of this technology makes it available for a wider application than military use, and makes it accessible to pharmaceutical and academic research. In this case study, real-time bioaerosol monitors (RBMs) were applied in elementary school classrooms—a densely occupied environment—along with upper-room ultraviolet germicidal irradiation (UVGI) devices. The classrooms were separated into a UVGI group and a non-UVGI control group. Fluorescent bioaerosol counts (FBCs) were monitored on 20 visiting days over a four-month period. The classroom with upper-room …


Social Sustainability Indicators In Mass Housing Construction, Ali Karji, Asregedew Woldesenbet, Mostafa Khanzadi Jan 2017

Social Sustainability Indicators In Mass Housing Construction, Ali Karji, Asregedew Woldesenbet, Mostafa Khanzadi

Durham School of Architectural Engineering and Construction: Faculty Publications

In the construction industry, buildings constitute more than half of the new construction built in the world. With the rapid growth of population in urban areas and high-energy consumption of buildings, considerable attention and efforts have been devoted to creating a sustainably built environment. As a result, various sustainable rating systems, principles and tools have been developed in recent years. This paper presents efforts underway for evaluation of sustainability in mass housing construction projects in the Middle East from a social aspect. The study reviews reports, guidelines and best practices at national and international levels to detect key sustainability indicators. …


Heat - Pump System With Refrigerant Charge Diagnostics, Fadi M. Alsaleem, Gregg H. Hemmelgarn Jan 2017

Heat - Pump System With Refrigerant Charge Diagnostics, Fadi M. Alsaleem, Gregg H. Hemmelgarn

Durham School of Architectural Engineering and Construction: Faculty Publications

A heat-pump circuit may include an indoor heat exchanger, an outdoor heat exchanger, a compressor adapted to circulate a working fluid between the indoor and outdoor heat exchangers, and an expansion device disposed between the indoor and outdoor heat exchangers. A monitor for the heat-pump system may include a return-air temperature sensor, a supply-air temperature sensor, and a processor. The return-air temperature sensor may be adapted to measure a first air temperature of air upstream of the indoor heat exchanger. The supply-air temperature sensor may be adapted to measure a second air temperature of air down stream of the indoor …


Mechanical And Thermal Evaluation Of Different Types Of Pcm-Concrete Composite Panels, Dervilla Niall, Oliver Kinnane, Roger West, Sarah Mccormack Aug 2016

Mechanical And Thermal Evaluation Of Different Types Of Pcm-Concrete Composite Panels, Dervilla Niall, Oliver Kinnane, Roger West, Sarah Mccormack

Conference papers

ABSTRACT: Thermal mass indicates the ability of a material to store and release heat and is a function of the heat storage capacity of a material. The thermal mass of construction materials can be used to reduce the energy required for heating and cooling buildings. The heat storage capacity of concrete can be increased by incorporating phase change materials (PCMs) into the concrete and hence providing additional latent heat storage capacity. Research was carried out to compare the thermal behaviour of two different types of PCM/concrete composite panels. The first type of panel was formed by adding microencapsulated paraffin to …


The Chorro Valley Trail From Cal Poly To Cuesta College, Nichole M. Garner Jun 2016

The Chorro Valley Trail From Cal Poly To Cuesta College, Nichole M. Garner

City and Regional Planning

No abstract provided.


Far West Water Ski Club Floating Dock Replacement, Jeffery L. Hadley Jun 2016

Far West Water Ski Club Floating Dock Replacement, Jeffery L. Hadley

Construction Management

A project based senior project, the Far West Floating Dock Project included the design, procurement and construction of two 20’x 20’ floating docks for the Lake Nacimiento based nonprofit Far West Water Ski Club. Constructed of polyethylene coated floats, 4x Pressure Treated lumber, hot-dipped galvanized hardware and composite decking, the dock is designed to have a lifespan of at least 35-40 years. This case study provides an overview of the complete project delivery, beginning with the conception and research, transitioning to design and procurement, and finishing with construction and lessons learned. The overall project cost landed at $21,712.00, made possible …


Is Zero Net Energy 2020 Actually Attainable, Perceptions Of Various Professionals Effected, Michael Aldridge Jun 2016

Is Zero Net Energy 2020 Actually Attainable, Perceptions Of Various Professionals Effected, Michael Aldridge

Construction Management

California has created a mandate that will require all new residential buildings to become Zero Net Energy by 2020. Some are already doing it others don’t know what it means, and some don’t think it will be possible. Those that already do it are doing it without any extra cost. All that is required is, on average, a 4KW roof solar panel system. This is something that easy to install and only requires a little more planning during the design phase. There are many other things that a designer and builder can do to successfully reach ZNE including focus on …


De-Westernizing The Far East, Jericho K. Kakaio-Edwards May 2016

De-Westernizing The Far East, Jericho K. Kakaio-Edwards

Undergraduate Honors Theses

Isolated by the Tibetan highlands which frame Yunnan’s northwest fringes, the ethnic minorities who call the region home live in rural settings ranging from rice-terraced fields to tropical forests; lifestyle unchanged for hundreds of years. However, with globalization causing an exposure to western standards of living, in conjunction with the country’s predisposition towards all things foreign, the people of Yunnan have begun forgoing generations of vernacular architecture in favor of modern materials and regionally defunct construction methods. Here, we will seek to address this foible of architectural development by offering theoretical construction methods for housing types found throughout the region, …


Green Building Rating Systems And The Role Of The Project Manager, Davis Ciprikis Apr 2016

Green Building Rating Systems And The Role Of The Project Manager, Davis Ciprikis

Other Resources

Sustainable development has increased significantly over the last 10 years. Construction firms are adopting sustainable practices that come from both, internal and external drivers of the construction industry. In order to assess how sustainable a building is, a green building rating systems have been developed to provide a documented and systematic approach to sustainable construction practices. Amongst these rating systems are the Building Research Establishment Environmental Assessment Methods (BREEAM) introduced in the UK and the Leadership in Energy and Environmental Design (LEED) created in the USA. It has been noted that the project manager will have an important role to …


Thermal Mass Behaviour Of Concrete Panels Incorporating Phase Change Materials, Dervilla Niall, Roger West, Sarah Mccormack, Oliver Kinnane Mar 2016

Thermal Mass Behaviour Of Concrete Panels Incorporating Phase Change Materials, Dervilla Niall, Roger West, Sarah Mccormack, Oliver Kinnane

Conference papers

Phase Change Materials (PCM) have been incorporated into a range of building envelope materials with varied success. This study investigates two different methods of combining concrete and phase change materials to form PCM/concrete composite panels. The first method involves adding microencapsulated paraffin to fresh concrete during the mixing process. The second method involves vacuum impregnating butyl stearate into lightweight aggregate which is then included in the concrete mix design. The primary aim of the study is to determine which method is the most effective way to improve the thermal mass characteristics of a concrete panel in the context of a …


Development Of Coordination Control For Multiple Rooftop Units, Denchai Woradechjumroen, Haorong Li, Akekachai Deesiri Jan 2016

Development Of Coordination Control For Multiple Rooftop Units, Denchai Woradechjumroen, Haorong Li, Akekachai Deesiri

Durham School of Architectural Engineering and Construction: Faculty Publications

Rooftop Units (RTUs) have been widely applied in providing space heating and cooling for commercial buildings. In total, they serve over 60% of the commercial building floor space in the U.S. Even through the current control approaches of a RTU can maintain the zone temperature corresponding to a set point temperature, it performs inefficiently due to several factors such as limited sensing capability, non- coordinated local control, inherent oversizing effects and so on. In addition to unnecessary power consumptions, the current control and operation technology on RTUs also lead to the space humidity problem, equipment efficiency degradation, and premature failure. …


A Need For Evidence-Based And Multidisciplinary Research To Study The Effects Of The Interaction Of School Environmental Conditions On Student Achievement, Josephine Lau, Lily M. Wang, Clarence E. Waters, James A. Bovaird Jan 2016

A Need For Evidence-Based And Multidisciplinary Research To Study The Effects Of The Interaction Of School Environmental Conditions On Student Achievement, Josephine Lau, Lily M. Wang, Clarence E. Waters, James A. Bovaird

Durham School of Architectural Engineering and Construction: Faculty Publications

With funding from the U.S. Environmental Protection Agency’s (EPA) Healthy Schools initiative, a research team from the University of Nebraska– Lincoln (UNL) is currently working on establishing how environmental conditions in K-12 school buildings impact student scholastic achievement. The objectives of the research project are: (1) to study comprehensively the impacts of a wide set of indoor environmental factors (including indoor air quality, thermal, lighting and acoustic conditions) on student achievement; (2) to investigate how these environmental conditions interact with each other to impact student achievement; (3) to rank order the environmental variables in terms of their relative impact on …


Fault Diagnosis Of Refrigerant Charge Based On Pca And Decision Tree For Variable Refrigerant Flow Systems, Jiangyan Liu, Huanxin Chen, Jiangyu Wang, Guannan Li, Haorong Li, Wenju Hu Jan 2016

Fault Diagnosis Of Refrigerant Charge Based On Pca And Decision Tree For Variable Refrigerant Flow Systems, Jiangyan Liu, Huanxin Chen, Jiangyu Wang, Guannan Li, Haorong Li, Wenju Hu

Durham School of Architectural Engineering and Construction: Faculty Publications

Variable refrigerant flow (VRF) systems are easily subjected to performance degradation due to refrigerant leakage, mechanical failure or improper maintenance after years of operation. Ideal VRF systems should equip with fault detection and diagnosis (FDD) program to sustain its normal operation. This paper presents the fault diagnosis method for refrigerant charge faults of variable refrigerant flow (VRF) systems. It is developed based on the classification and regression tree (CART) algorithm. Data of the experimental VRF system is used to test the advantages of the CART method. Results show that the decision tree can achieve desirable diagnosis efficiency on undercharge faults, …


Cognitive Radio For Smart Grid With Security Considerations, Khaled Shuaib, Ezedin Barka, Nedaa Al Hussien, Mohammed Abdel-Hafez, Mahmoud Alahmad Jan 2016

Cognitive Radio For Smart Grid With Security Considerations, Khaled Shuaib, Ezedin Barka, Nedaa Al Hussien, Mohammed Abdel-Hafez, Mahmoud Alahmad

Durham School of Architectural Engineering and Construction: Faculty Publications

In this paper, we investigate how Cognitive Radio as a means of communication can be utilized to serve a smart grid deployment end to end, from a home area network to power generation. We show how Cognitive Radio can be mapped to integrate the possible different communication networks within a smart grid large scale deployment. In addition, various applications in smart grid are defined and discussed showing how Cognitive Radio can be used to fulfill their communication requirements. Moreover, information security issues pertained to the use of Cognitive Radio in a smart grid environment at different levels and layers are …