Open Access. Powered by Scholars. Published by Universities.®

Environmental Design Commons

Open Access. Powered by Scholars. Published by Universities.®

Architectural Engineering

Institution
Keyword
Publication Year
Publication
Publication Type
File Type

Articles 181 - 210 of 341

Full-Text Articles in Environmental Design

New Beginnings Homeless Transition Village, Community Design Center Jan 2018

New Beginnings Homeless Transition Village, Community Design Center

Community Design Center Project Reports

More than three million Americans experience homelessness annually. Emergency shelter capacity is limited while local governments are unable to provide even temporary housing. Informal housing involving interim self-help solutions are now popular adaptive actions for obtaining shelter despite nonconformance with city codes. Unfortunately, most informal solutions have resulted in objectionable tent cities and squatter campgrounds where the local response has simply been to move the problem around. Our homeless transition village plan prototypes a shelter-first solution using a kit-of-parts that can be replicated in other communities. Village design reconciles key gaps between informal building practices and formal sector regulations, creating …


Willow Heights Livability Improvement Plan, Community Design Center Jan 2018

Willow Heights Livability Improvement Plan, Community Design Center

Community Design Center Project Reports

Willow Heights is a 43-year old public housing complex owned by the Fayetteville Housing Authority (FHA) within the federal public housing portfolio administered by the Department of Housing and Urban Development (HUD). The school’s design center was commissioned by a local foundation to study an alternative to the FHA’s plan to sell the downtown Willow Heights complex to a developer of high-income housing, necessitating relocation of low-income residents to another complex outside of downtown. Using equity as a driver of decision making, the studio introduced scenario planning to organize reluctant stakeholders in considering transformations to the five-acre complex.


Numerical Simulation Of Fault Impacts For Commercial Walk-In Freezers, Alireza Behfar, David P. Yuill Jan 2018

Numerical Simulation Of Fault Impacts For Commercial Walk-In Freezers, Alireza Behfar, David P. Yuill

Durham School of Architectural Engineering and Construction: Faculty Publications

Refrigeration systems can undergo many faults that could negatively affect their operation and performance. This paper describes a modeling process to simulate the fault impacts on the operation of a commercial walk-in freezer using semi-empirical models. These models often require less modeling effort than full forward models and could be used in scenarios where detailed information is missing, such as in field-measured systems. An important characteristic of a typical walk-in refrigeration system is the existence of a liquid-line receiver after the condenser, which significantly changes the behavior of the cycle, in comparison to a receiver-less system. Component models described in …


Simultaneous Electrical And Mechanical Resonance Drive For Large Signal Amplification Of Micro Resonators, M. H. Hasan, Fadi M. Alsaleem, N. Jaber, M. A. A. Hafiz, M. I. Younis Jan 2018

Simultaneous Electrical And Mechanical Resonance Drive For Large Signal Amplification Of Micro Resonators, M. H. Hasan, Fadi M. Alsaleem, N. Jaber, M. A. A. Hafiz, M. I. Younis

Durham School of Architectural Engineering and Construction: Faculty Publications

Achieving large signal-noise ratio using low levels of excitation signal is key requirement for practical applications of micro and nano electromechanical resonators. In this work, we introduce the double electromechanical resonance drive concept to achieve an order-of-magnitude dynamic signal amplification in micro resonators. The concept relies on simultaneously activating the micro-resonator mechanical and electrical resonance frequencies. We report an input voltage amplification up to 15 times for a micro-resonator when its electrical resonance is tuned to match the mechanical resonance that leads to dynamic signal amplification in air (Quality factor enhancement). Furthermore, using a multi-frequency excitation technique, input voltage and …


Impact Of Owners’ Early Decisions On Project Performance And Dispute Occurrence In Public Highway Projects, Sogand Hasanzadeh, Behzad Esmaeili, Ghada M. Gad, Douglas D. Gransberg Jan 2018

Impact Of Owners’ Early Decisions On Project Performance And Dispute Occurrence In Public Highway Projects, Sogand Hasanzadeh, Behzad Esmaeili, Ghada M. Gad, Douglas D. Gransberg

Durham School of Architectural Engineering and Construction: Faculty Publications

Disputes are common in the construction industry and lead to unnecessary cost and schedule overruns in projects. It is commonly believed that owners’ early decisions regarding the selection of delivery methods, procurement methods, and contract types impact the frequency and severity of project disputes; however, no previous study has empirically tested this hypothesis, particularly in highway public projects. Therefore, this study empirically investigated the impact of owners’ early decisions regarding project organization (i.e., delivery methods, procurement, and contract types) on performance measures (e.g., cost and schedule growth), specifically dispute performance metrics (e.g., frequency and severity of disputes), in public highway …


Method For Radon Measurement In Residential Sewer Connections, David Yuill Jan 2018

Method For Radon Measurement In Residential Sewer Connections, David Yuill

Durham School of Architectural Engineering and Construction: Faculty Publications

Radon gas is the most deadly indoor air pollutant. In the US, it is responsible for over 20,000 deaths per year. Residential exposure is typically the largest portion of a person’s annual exposure, so a great deal of research has been done to understand the pathways that radon can follow to enter a house. Since radon emanates from the ground, it is present in high concentration in soil gas. Recent research on the vapor intrusion of volatile organic compounds from subsurface sources into a test house concluded that the sewer line is an important preferential pathway. Despite the potential for …


Utilizing Wearable Devices To Design Personal Thermal Comfort Model, Mostafa Rafaie, Mehari Tesfay, Fadi Alsaleem Jan 2018

Utilizing Wearable Devices To Design Personal Thermal Comfort Model, Mostafa Rafaie, Mehari Tesfay, Fadi Alsaleem

Durham School of Architectural Engineering and Construction: Faculty Publications

have confirmed that thermal comfort significantly depends on internal personal parameters such as metabolic rate, age, and health status. This is manifested as a difference in comfort levels between people residing under the same roof, and hence no general comprehensive comfort model satisfying everyone. Current and newly emerging advancements in state of the art wearable technology have made it possible to continuously acquired biometric information. This work proposes to access and exploit this data to build personal thermal comfort model. Relying on various supervised machine-learning methods, a personal thermal comfort model will be produced and compared to a general model …


Localized Indoor Temperature Estimation Using Smartphone And Laptop Internal Sensors, Mostafa Rafaie, Mehari Tesfay, Fadi Alsaleem Jan 2018

Localized Indoor Temperature Estimation Using Smartphone And Laptop Internal Sensors, Mostafa Rafaie, Mehari Tesfay, Fadi Alsaleem

Durham School of Architectural Engineering and Construction: Faculty Publications

This paper investigates a mechanism in which indoor air temperature can be predicted using the temperature sensor on the battery and the CPU of smartphones or laptops, where data is easily accessible and ubiquitous. As a case study, several machine-learning methods were used to build models from a laptop data and the measured surrounding air temperature. The effects of the machine learning type and input feature size (by including other parameters such as CPU processing usage and battery charge percentage) on the model accuracy were investigated. The goal is to determine a set of feature combinations that can be used …


Comfort-Based Optimal Temperature Setpoint Calculation, Andrew Holthaus, Mostafa Rafaie, Fadi Alsaleem Jan 2018

Comfort-Based Optimal Temperature Setpoint Calculation, Andrew Holthaus, Mostafa Rafaie, Fadi Alsaleem

Durham School of Architectural Engineering and Construction: Faculty Publications

General practice in current building HVAC control is to select building temperature setpoints that comply with ASHRAE Standard 55. By meeting this standard, based on the PMV comfort model, 80% of building occupants should be satisfied with their thermal environment. However, unfortunately, this is rarely the case. One possible reason for this is the variation in occupant activity and clothing that are usually assumed default values using this standard. In this work, we present an iterative-based algorithm to solve this problem. The algorithm solves the PMV inverse model equation to determine the optimal temperature setpoint while inferring human activity level …


Sdnet2018: An Annotated Image Data Set For Non-Contact Concrete Crack Detection Using Deep Convolutional Neural Networks, Sattar Dorafshan, Robert J. Thomas, Marc Maguire Jan 2018

Sdnet2018: An Annotated Image Data Set For Non-Contact Concrete Crack Detection Using Deep Convolutional Neural Networks, Sattar Dorafshan, Robert J. Thomas, Marc Maguire

Durham School of Architectural Engineering and Construction: Faculty Publications

SDNET2018 is an annotated image data set for training, validation, and benchmarking of artificial intelligence based crack detection algorithms for concrete. SDNET2018 contains over 56,000 images of cracked and non-cracked concrete bridge decks, walls, and pavements. The dataset includes cracks as narrow as 0.06 mm and as wide as 25 mm. The data set also includes images with a variety of obstructions, including shadows, surface roughness, scaling, edges, holes, and background debris. SDNET2018 will be useful for the continued development of concrete crack detection algorithms based on deep convolutional neural networks (DCNNs), which are a subject of continued research in …


Evaluation The Effect Of Washing On The Heat Transfer Capacity And Air-Side Flow Resistance Of Air Cooled Condensers, Mehdi Mehrabi, David Yuill Jan 2018

Evaluation The Effect Of Washing On The Heat Transfer Capacity And Air-Side Flow Resistance Of Air Cooled Condensers, Mehdi Mehrabi, David Yuill

Durham School of Architectural Engineering and Construction: Faculty Publications

17th International Refrigeration and Air Conditioning Conference at Purdue, July 9-12, 2018


Infrared Thermography For Weld Inspection: Feasibility And Application, Sattar Dorafshan, Marc Maguire, William Collins Jan 2018

Infrared Thermography For Weld Inspection: Feasibility And Application, Sattar Dorafshan, Marc Maguire, William Collins

Durham School of Architectural Engineering and Construction: Faculty Publications

Traditional ultrasonic testing (UT) techniques have been widely used to detect surface and sub-surface defects of welds. UT inspection is a contact method which burdens the manufacturer by storing hot specimens for inspection when the material is cool. Additionally, UT is only valid for 5 mm specimens or thicker and requires a highly skilled operator to perform the inspections and interpret the signals. Infrared thermography (IRT) has the potential to be implemented for weld inspections due to its non-contact nature. In this study, the feasibility of using IRT to overcome the limitations of UT inspection is investigated to detect inclusion, …


Hvac System Remote Monitoring And Diagnosis Of Refrigerant Line Obstruction, Fadi M. Alsaleem Jan 2018

Hvac System Remote Monitoring And Diagnosis Of Refrigerant Line Obstruction, Fadi M. Alsaleem

Durham School of Architectural Engineering and Construction: Faculty Publications

A heating, ventilation, and air conditioning (HVAC) system of a building includes a refrigerant loop. A monitoring system for the HVAC system includes a monitoring device installed at the building. The monitoring device is configured to measure a first temperature of refrigerant in a refrigerant line located between a filter - drier of the refrigerant loop and an expansion valve of the refrigerant loop. The monitoring system includes a monitoring server, located remotely from the building. The monitoring server is con figured to receive the first temperature and, in response to the first temperature being less than a threshold, generate …


Bridge Build, Andrew Little Nov 2017

Bridge Build, Andrew Little

Student Scholarship

Bridge build design that includes not only a building process, but a research paper to make the best build possible as well.


Shower Atomization, Chirag Ayappa Ravishankar, Jul 2017

Shower Atomization, Chirag Ayappa Ravishankar,

Masters Theses & Specialist Projects

The research will help to design a shower for Dr. Chelson’s shelter, which can control the water flow, pressure and duration of the shower, which optimizes the utilization of water. The showers could be used in drought-hit areas where water is very scarce, as daily sanitation needs are necessary to keep a person safe and healthy without wasting water. The report from, World Health Organization shows that showers consume the most water. A timed shower could help resolve this issue through eliminating the wastage. Eco-friendly environmentalists may also be attracted to the showers, as their main purposes are to save …


Examination Of Leed Certified Building’S Electricity Usage, Nasim Amiri Jul 2017

Examination Of Leed Certified Building’S Electricity Usage, Nasim Amiri

Masters Theses & Specialist Projects

The number of buildings seeking LEED certification has been growing steadily over the past few years. In this study, three academic buildings which were designed and built to LEED certification standards were targeted in Bowling Green, Kentucky. Their electricity consumption and cost effectiveness were examined and compared with predesigned LEED efficiency models of those three buildings. This research directly examined cost effectiveness of LEED buildings in terms of electricity usage. Three case studies were completed to find the initial and on-going electricity costs of LEED buildings and to verify the LEED standard results. LEED aspects of these buildings were discussed …


Gas Collection, Haorong Li, Yanshun Yu, Daihong Yu Jun 2017

Gas Collection, Haorong Li, Yanshun Yu, Daihong Yu

Durham School of Architectural Engineering and Construction: Faculty Publications

A system includes a vessel configured to couple with a gas source for drawing gas into the vessel. The vessel is also configured to receive liquid. The system includes an over flow port in fluid communication with the environment external to the vessel. The overflow port is configured to separate gas within the vessel from the external environment. The system also includes an overflow conduit having an end within the overflow port so that when gas pressure within the vessel increases, liquid is received by the over flow conduit. Another system includes a tank defining an air space for receiving …


Mano De La Amistad: A Thin Shell Concrete Structure Designed For The People Of Havana, Cuba, Peter Aster, Marta Blachowicz-Scott, Aaron Cook, Alex Erler, Elizabeth Townsend, Ger Yang Jun 2017

Mano De La Amistad: A Thin Shell Concrete Structure Designed For The People Of Havana, Cuba, Peter Aster, Marta Blachowicz-Scott, Aaron Cook, Alex Erler, Elizabeth Townsend, Ger Yang

Architectural Engineering

In designing a thin shell structure to cover the performance space on Tribuna Anti Imperialista Jose Marti, in Havana, Cuba, we developed a heavily symbolic concept and further abstracted it to reach our design. Basing the concept on the quote to the right by Obama about US and Cuba relations, we wanted our design to be representative of a hand that works to adjoin the plaza to the US Embassy which is directly west of the site. The “wrist” portion adds an asymmetric element, while the fingers provide a backdrop to the performers as well as a view through to …


The Ginkgo Shell, Mark Luzi, Karla Santos, Josh Cannon, Erika Davis, Nora Villanueva Jun 2017

The Ginkgo Shell, Mark Luzi, Karla Santos, Josh Cannon, Erika Davis, Nora Villanueva

Architectural Engineering

The overall concept for this outdoor concrete shell structure, located in Furstliche Park in Inzigkofen, Germany, is derived from an abstracted ginkgo leaf. Drawing on inspiration from a poem about the two parts of the ginkgo leaf becoming one, we took the approach of combining both the natural and built environment into one cohesive piece. To connect the two, it was imperative that we place the shell on the site as to have the smallest impact. With a small portion of the overall site used, the unoccupied space further enhances the natural environment. Creating a literal design connection between the …


Offshore R+D Facility, Philip A. Marble May 2017

Offshore R+D Facility, Philip A. Marble

Bachelor of Architecture Theses - 5th Year

Design a Research + Development facility that merges with a functional Oil Rig. This center will house both a Marine Research Center and Oil rig Research + Development center. Both of these facilities will be in a separate structure than the Oil Rig but will have a connection back to the Living Quarter.


How Tonality And Loudness Of Noise Relate To Annoyance And Task Performance” Noise Control Eng. J. 65(2), 71-82., Joonhee Lee, Jennifer M. Francis, Lily M. Wang Apr 2017

How Tonality And Loudness Of Noise Relate To Annoyance And Task Performance” Noise Control Eng. J. 65(2), 71-82., Joonhee Lee, Jennifer M. Francis, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

Audible tones in noise generated by building mechanical equipment can be a leading cause of complaints from occupants. A number of metrics have been developed to quantify prominence of a tone, but previous work has shown that the impact of a certain tonality appears to vary with the level of the broadband noise signal. More work on how tonal signals of varying tonality, tone frequency and broadband noise levels relate to annoyance and task performance is needed. This paper investigates such relationships between current noise metrics, annoyance and task performance under assorted tonal noise conditions through subjective testing. Participants rated …


Clothedral, Jacob T. Holmes, Andres Munoz, Sam Tenreiro Theis, Marta Blachowicz Mar 2017

Clothedral, Jacob T. Holmes, Andres Munoz, Sam Tenreiro Theis, Marta Blachowicz

Architectural Engineering

No abstract provided.


Bau, January 17-21, Munich, Jim Roche Feb 2017

Bau, January 17-21, Munich, Jim Roche

Other resources

This bi-annual five-day event is one of the

leading and biggest trade fares of architecture,

materials, building systems and craft skills in

the world. Held in the huge Messe München

Trade Fair Center in eastern Munich and

stretching over 17 gigantic halls each the size

of a football pitch, it offers a truly rich display of

the latest innovations in building technology.


The Freeman Performing Arts Center, Community Design Center Jan 2017

The Freeman Performing Arts Center, Community Design Center

Community Design Center Project Reports

The Freeman Performing Arts Center marks the threshold between prairie and civic life. This small agricultural community of 1,300 has an outsized Anabaptist music tradition recognized nationally. The 37,000 sf hall-type building unifies a miscellaneous collection of public buildings and landscapes at the southwest corner of the town’s one-mile grid. The center’s massing projects an ascending system of familiar gable roofs, which absorb the fly tower into a composition reflective of pragmatic building forms. The principal face of the building is a translucent curtain wall that illuminates interior massing—a beacon on the prairie. A thru-Porch celebrates transitions between the prairie’s …


Research On Control Methods Of Roof Radiant Cooling System, Yongbin Li, Zhaoyi Zhuang, Qiqi Zhu, Jian Song, Haipeng An Jan 2017

Research On Control Methods Of Roof Radiant Cooling System, Yongbin Li, Zhaoyi Zhuang, Qiqi Zhu, Jian Song, Haipeng An

Durham School of Architectural Engineering and Construction: Faculty Publications

Taking the capillary ceiling radiation air conditioning system in radiation cooling Laboratory of comprehensive experimental building in Shandong Jianzhu University as an example, research the two different control methods which are room temperature control and water temperature control. The roof cooling model was established by using TRNSYS simulation software, two typical summer days were selected to explore the stability of the room temperature and the supply and return water temperature, research the comfort of human body and system energy consumption under two control methods. The results show that the indoor temperature of the two control methods can be stable at …


Gas Generation, Haorong Li, Daihong Yu, Yanshun Yu Jan 2017

Gas Generation, Haorong Li, Daihong Yu, Yanshun Yu

Durham School of Architectural Engineering and Construction: Faculty Publications

A first system includes a feedstock load port and a feedstock discharge port. The first system also includes a tank configured to retain biomass feedstock for aerobic biodegradation. The first system further includes a mechanical ventilator in fluid communication with the tank. The mechanical ventilator is configured to supply air to facilitate the aerobic biodegradation of the biomass feedstock. The first system also includes an exhaust port configured to receive gas generated during the aerobic biodegradation. A second system includes a feedstock load port and a feedstock discharge port. The second system also includes a pressure vessel configured to retain …


Study On The Methods For Predicting The Performance Of A Hybrid Solar-Assisted Ground-Source Heat Pump System, Zhaoyi Zhuang, Qiqi Zhu, Jian Song, Xin Zhang, Haorong Li Jan 2017

Study On The Methods For Predicting The Performance Of A Hybrid Solar-Assisted Ground-Source Heat Pump System, Zhaoyi Zhuang, Qiqi Zhu, Jian Song, Xin Zhang, Haorong Li

Durham School of Architectural Engineering and Construction: Faculty Publications

It is critical to find suitable setting parameters for designing a hybrid solar-assisted ground-source heat pump system in the practical engineering application, but the heat pump performance is unpredictable after many years of operation. This paper used 2000 sets of performance data collected from solar-assisted GSHP systems that keep operating over 20 years to simulate long term used heat pump with a professional software called GeoStar. Adopted the classification and regression tree (CART) method, the design of solar energy collector areas can be predicted. The multi-linear regression is also utilized to predict average monthly per meter borehole heat exchange. Seasonal …


Research On The Cooling Characteristics In Building Interior Zones Using Displacement Ventilation System, Zhaoyi Zhuang, Yongbin Li, Qiqi Zhu, Jian Song, Haipeng An, Haorong Li Jan 2017

Research On The Cooling Characteristics In Building Interior Zones Using Displacement Ventilation System, Zhaoyi Zhuang, Yongbin Li, Qiqi Zhu, Jian Song, Haipeng An, Haorong Li

Durham School of Architectural Engineering and Construction: Faculty Publications

The outdoor low temperature fresh air can be used as a free cold source to eliminate waste heat for the building interior zones during the transition season and winter. This paper takes a project in Hunan as an example, and the project building interior zones is 25m×7m×3.9m(L×W×H). Using Fluent software to simulate the temperature field and velocity field both the interior and exterior zones of the engineering offices. The simulation results show that using the displacement ventilation system to take the outdoor air into inner rooms not only cooling but also improving the air quality and adding comfort. According to …


Performance And Energy Efficiency Analysis Of Data Center Cooling Plant By Using Lake Water Source, Li Ling, Quan Zhang, Liping Zeng Jan 2017

Performance And Energy Efficiency Analysis Of Data Center Cooling Plant By Using Lake Water Source, Li Ling, Quan Zhang, Liping Zeng

Durham School of Architectural Engineering and Construction: Faculty Publications

A cooling plant by using lake water source was proposed to cool the space in data centers. It combines free cooling technology and variable capacity technology to remove heat and reduce energy consumption effectively. In this paper, firstly, the control strategies for this cooling plant were proposed. Then, a detailed annual energy consumption model with considering the effect of the dynamic heat dissipation characteristics of servers, lake water temperature, outdoor weather conditions, and cooling plant thermal performance, will be established to evaluate the performance and energy efficiency of this cooling plant under different load factors. The results show the mode …


Hvac System Remote Monitoring And Diagnosis, Jeffrey N. Arensmeier, Gregg M. Hemmelgarn, Fadi M. Alsaleem, Priotomo Abiprojo Jan 2017

Hvac System Remote Monitoring And Diagnosis, Jeffrey N. Arensmeier, Gregg M. Hemmelgarn, Fadi M. Alsaleem, Priotomo Abiprojo

Durham School of Architectural Engineering and Construction: Faculty Publications

A monitoring system for a heating, ventilation, and air conditioning (HVAC) system of a building includes a monitoring device installed at the building, a monitoring server located remotely from the building, and a review server. The monitoring device measures an aggregate current Supplied to components of the HVAC system and transmits current data based on the measured aggregate current. The monitoring server receives the transmitted current data and, based on the received current data, assesses whether failures have occurred in first and second components of the HVAC components. The monitoring server generates a first advisory in response to determining that …