Open Access. Powered by Scholars. Published by Universities.®

Architectural Engineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

2012

Discipline
Institution
Keyword
Publication
Publication Type
File Type

Articles 31 - 60 of 76

Full-Text Articles in Architectural Engineering

College And Industry Partnerships: The Samé, Tanzania Polytechnic And Weld Quality, Craig Baltimore, Allen C. Estes Jun 2012

College And Industry Partnerships: The Samé, Tanzania Polytechnic And Weld Quality, Craig Baltimore, Allen C. Estes

Architectural Engineering

No abstract provided.


Ten Years Of Abet Ec 2000: One Person's Reflections, Allen Estes Jun 2012

Ten Years Of Abet Ec 2000: One Person's Reflections, Allen Estes

Architectural Engineering

ABET accreditation criteria changed substantially at the turn of the century changing from a prescriptive, curricular-based standard to an outcomes-based approach for accreditation. The new system named Engineering Criteria (EC) 2000 required engineering programs to consult with their constituencies to establish program objectives and outcomes that define what their graduates will attain several years after graduation and at the time of graduation, respectively. The accreditation process involves assessing the degree to which graduates are attaining these outcomes and objectives and using the results to make changes and continuously improve the program. Most engineering programs have now been through two cycles …


Civil Engineering Program Evaluator Reflections: The Most Recent Lessons Learned, Karl F. Meyer, Allen Estes, Paul Francis Mlakar Jun 2012

Civil Engineering Program Evaluator Reflections: The Most Recent Lessons Learned, Karl F. Meyer, Allen Estes, Paul Francis Mlakar

Architectural Engineering

For the 2011-2012 ABET accreditation cycle, a number of changes across the criteria have impacted the way in which programs must approach their accreditation efforts.1 The most significant change is related to the reporting of assessment activities and their use for program improvement. For the first time this year, assessment results of program educational objectives and student outcomes are reported in Criterion 4, Continuous Improvement. Additionally, there have been changes to the former Criterion 9, Program Criteria. The Program Criteria is no longer numbered, but more importantly, contains some fairly significant changes impacting the assessment of student performance. The changes …


Multinomial Logistic Regression Model For Single-Vehicle And Multivehicle Collisions On Urban U.S. Highways In Arkansas, Ghulam Bham, Bhanu S. Javvadi, Uday R.R. Manepalli Jun 2012

Multinomial Logistic Regression Model For Single-Vehicle And Multivehicle Collisions On Urban U.S. Highways In Arkansas, Ghulam Bham, Bhanu S. Javvadi, Uday R.R. Manepalli

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

Multivariate analysis can be used to identify the effects of several factors on the causes of a crash compared with univariate analysis. This paper uses a multivariate-analysis technique, the multinomial logistic regression (MLR) model, to examine the differences in crash-contributing factors for six collision types for both divided- and undivided-highway nonjunctions, given that a crash has occurred. Multinomial logistic regression was used to investigate (1) single-vehicle and (2) multivehicle collisions, which included (1) angular, (2) head-on, (3) rear-end, (4) sideswipe-same-direction, and (5) sideswipe-opposite-direction collisions. the risks associated with different collision types were found to be significantly influenced by various vehicle …


Development And Testing Of Chemically-Based Self-Consolidating Concrete, Mahdi Arezoumandi, Mark Ezzell, Jeffery S. Volz Jun 2012

Development And Testing Of Chemically-Based Self-Consolidating Concrete, Mahdi Arezoumandi, Mark Ezzell, Jeffery S. Volz

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

Self-consolidating concrete (SCC) has the potential to significantly reduce costs associated with concrete construction. SCC is a highly flowable, Non segregating concrete that has a variety of advantages over conventional concrete (CC). However, SCC is not without its problems, which can include increased creep and shrinkage, as well as decreased bond and shear strength. the goal of this research project was to evaluate the creep, shrinkage, and shear behavior of a chemically Based SCC mix. One of the benefits of a chemically Based approach is the potential to eliminate the negative side effects of many SCC mixes. the investigation included …


High-Volume Fly Ash Concrete For Sustainable Construction, Jeffery S. Volz Jun 2012

High-Volume Fly Ash Concrete For Sustainable Construction, Jeffery S. Volz

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

With worldwide production of fly ash approaching 800 million tons annually, increasing the amount of fly ash used in concrete will remove more material from the solid waste stream and reduce the amount ending up in landfills. However, most specifications limit the amount of cement replacement with fly ash to less than 25 or 30%. Concrete with fly ash replacement levels of at least 50% - referred to as high-volume fly ash (HVFA) concrete - offers a potential green solution. the following study investigated the structural performance of HVFA concrete compared to conventional Portland-cement concrete. Specifically, the research examined both …


Performance-Based Analysis Of A Reinforced Concrete Shear Wall Building, Garrett Richard Hagen Jun 2012

Performance-Based Analysis Of A Reinforced Concrete Shear Wall Building, Garrett Richard Hagen

Master's Theses

PERFORMANCE-BASED ANALYSIS OF A REINFORCED CONCRETE SHEAR WALL BUILDING

Garrett Richard Hagen

In this thesis, a special reinforced concrete shear wall building was designed per ASCE 7-05, and then the performance was investigated using the four analysis procedures outlined in ASCE 41-06. The proposed building was planned as a 6-story office building in San Francisco, CA. The structural system consisted of a two-way flat plate and reinforced concrete columns for gravity loads and slender structural walls for seismic loads. The mathematical building models utilized recommendations from ASCE 41-06 and first-principle mechanics. Moment-curvature analysis and fiber cross-section elements were used in …


Damage Detection In Metamorphic Stone Blocks Utilizing Impact-Echo Testing And Modal Analysis, Alexander C. Jording May 2012

Damage Detection In Metamorphic Stone Blocks Utilizing Impact-Echo Testing And Modal Analysis, Alexander C. Jording

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

Existing buildings decay with the passage of time, and as a result, continually require maintenance or rehabilitation. When considering existing structures, testing is often necessary to complete structural analysis in preparation for rehabilitation or repair. Non-destructive testing provides a structural assessment method applicable to a variety of materials and structures. The hypothesis of this research is that impact-echo testing, one of the many NDT techniques, can be adopted to develop a reliable and standardized method to assess the condition of rectangular metamorphic stones. After the baseline material parameters and general response to impact-echo testing were established, a novel method to …


Assessing The Engineering Performance Of Affordable Net-Zero Energy Housing, Jordan P. Wallpe May 2012

Assessing The Engineering Performance Of Affordable Net-Zero Energy Housing, Jordan P. Wallpe

Purdue Polytechnic Masters Theses

The purpose of this research was to evaluate affordable technologies that are capable of providing attractive, cost-effective energy savings to the housing industry. The research did so by investigating the 2011 Solar Decathlon competition, with additional insight from the Purdue INhome. Insight from the Purdue INhome verified the importance of using a three step design process to design a net-zero energy building. In addition, energy consumption values of the INhome were used to compare and contrast different systems used in other houses.

Evaluation of unbiased competition contests gave a better understanding of how a house can realistically reach net-zero. Upon …


Electromagnetic Harvesting To Power Energy Management Sensors In The Built Environment, Evans Sordiashie May 2012

Electromagnetic Harvesting To Power Energy Management Sensors In The Built Environment, Evans Sordiashie

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

Recently, a growing body of scholarly work in the field of energy conservation is focusing on the implementation of energy management sensors in the power distribution system. Since most of these sensors are either battery operated or hardwired to the existing power distribution system, their use comes with major drawbacks. Battery maintenance and associated labor costs can make implementing sensors very expensive. Although hardwired sensors require very little post-installation maintenance, any energy savings they may procure is offset by the amount of energy expended during the course of the sensors normal operation. In response to these energy challenges, this thesis …


Residential Energy Recovery Radiant Heat System, Scott Sharp May 2012

Residential Energy Recovery Radiant Heat System, Scott Sharp

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

Energy recovery systems aim to recover waste energy that is normally lost to the environment. Waste energy comes in a variety of forms. Many processes involving building HVAC involves transferring energy from one working fluid to another. Governing codes put strict requirements on ventilation requirements for various occupancy types. Increased ventilation demands more from the HVAC equipment since outdoor air (ventilation air) is being brought into the building and requires tempering in order to retain occupant comfort. The energy required to temper this air increases as ventilation rates increase. Many commercial buildings have implemented exhaust air energy recovery, or runaround …


Structural Performance Of Reinforced Concrete Flat Plat Buildings Subjected To Fire, Sara Jean George May 2012

Structural Performance Of Reinforced Concrete Flat Plat Buildings Subjected To Fire, Sara Jean George

UNLV Theses, Dissertations, Professional Papers, and Capstones

Reinforced concrete structures are typically considered to have inherent resistance to fire. However, several concrete structures around the world have experienced partial or total collapse under fire. Reinforced concrete flat-plate is a type of structural system widely used for office and residential buildings. Flat plate construction is prone to punching shear failure at slab-column connections which may lead to a catastrophic progressive collapse. The slabs of flat-plates generally have very thin concrete cover leaving steel reinforcement more sensitive to thermal loads. Little is known in the engineering community about the structural performance of flat-plate structures subjected to fire. Through a …


A Composite Structural Steel And Prestressed Concrete Beam For Building Floor Systems, Nathan Dewit Apr 2012

A Composite Structural Steel And Prestressed Concrete Beam For Building Floor Systems, Nathan Dewit

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

Precast prestressed concrete beams, such as rectangular and inverted tee beam, currently used in residential and commercial buildings are deep, heavy, and limited to span-to-depth ratios of 15. The research proposes a composite structural steel and prestressed concrete beam that is shallow, light, easy to produce and erect, and able to achieve a span-to-depth ratio of 24. The proposed beam is designed to be used with precast columns, hollow-core planks, and a cast-in-place topping to create a moment-resisting floor system that minimizes the need for shear walls. The goal of this system is to eliminate as many of the limitations …


Monotonic Behavior Of Mississippi River Valley Silt In Triaxial Compression, Shuying Wang, Ronaldo Luna Apr 2012

Monotonic Behavior Of Mississippi River Valley Silt In Triaxial Compression, Shuying Wang, Ronaldo Luna

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

The static behavior of Mississippi River Valley silt was characterized using triaxial compression testing. Silt specimens, especially over consolidated ones, showed dilation behavior. There was no unique critical state among specimens with different over consolidation ratios (OCRs). with OCRs of 1, 2, and 8, the specimens exhibited normal behavior and dilated more as effective consolidation pressure dropped. However, for an OCR of 4, the specimens showed opposite behavior and dilated more as effective consolidation pressure rose. the friction angle of the silt was computed on the basis of several failure criteria, and the limiting strain was found to be the …


A Comparative Study Of Three Feedback Devices For Residential Real-Time Energy Monitoring, Mahmoud Alahmad, Patrick G. Wheeler, Joshua Eiden, Adam Brumbaugh Apr 2012

A Comparative Study Of Three Feedback Devices For Residential Real-Time Energy Monitoring, Mahmoud Alahmad, Patrick G. Wheeler, Joshua Eiden, Adam Brumbaugh

Durham School of Architectural Engineering and Construction: Faculty Publications

Residential energy consumption accounts for 21% of the total electricity use in the United States. Unfortunately, research indicates that almost 41% of this power is wasted. Changing the way that consumers use energy may be important in reducing home energy consumption. This paper looks at whether the implementation of certain real-time energy monitors has an impact on the residential rate of energy consumption in a metropolitan area with relatively low electricity rates. In the following case study, 151 Omaha residences were equipped with two variants of the Aztech In-Home Display (Aztech) as well as the Blue Line Power Cost Monitor …


The Assessment Of High Dynamic Range Luminance Measurements With Led Lighting, Yulia I. Tyukhova Apr 2012

The Assessment Of High Dynamic Range Luminance Measurements With Led Lighting, Yulia I. Tyukhova

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

This research investigates whether a High Dynamic Range Imaging (HDRI) technique can accurately capture luminance values of a single LED chip. Previous studies show that a digital camera with exposure capability can be used as a luminance mapping tool in a wide range of luminance values with an accuracy of 10%. Previous work has also demonstrated the ability of HDRI to capture a rapidly-changing lighting environment with the sun. However these publications don’t investigate HDRI’s ability to capture a bright light source with a narrow light distribution (LED lighting).

Some of the existing concerns in LED technology today include low …


A Numerical Investigation Of Two Phase Solar-Collector Pipe, Seyyed Hashem Abedini Apr 2012

A Numerical Investigation Of Two Phase Solar-Collector Pipe, Seyyed Hashem Abedini

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

In the United States, major portions of the annual electrical and primary energy are consumed for buildings. To help reduce the energy consumption of non-renewable energy sources, this study investigates a new technology for harvesting solar energy using a boiling-condensing cycle with water in a solar collector. The fluid circulation is under natural forced convection. A solar collector is made of a black lacquer copper with 2 meters in length is used. The design of the system is presented to simulate heat transfer rate in a cold climate an average daily solar irradiation of 4.5kWh/m2/day, e.g. for Omaha …


Factors Influencing Crack-Induced Tensile Strength Of Compacted Soil, Tae Hyung Kim, Tae Hoon Kim, Gi Chun Kang, Louis Ge Mar 2012

Factors Influencing Crack-Induced Tensile Strength Of Compacted Soil, Tae Hyung Kim, Tae Hoon Kim, Gi Chun Kang, Louis Ge

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

Mode I (tensile) fracture is the most commonly observed failure in Geostructure's resulting from cracks in soil. Direct or indirect tensile tests have been used to evaluate the tensile strength of geomaterials. in this paper, the unconfined penetration device and experimental procedure were modified to reduce measurement errors. It was then used to determine the tensile strength of compacted soil. Factors influencing the tensile strength of the compacted soil, including the plasticity index, rate of loading, and size of specimen were discussed in detail, as well as its reliability. Experimental results indicated that the modified, unconfined penetration technique is sufficiently …


Time-Weighted Average Spme Analysis For In Planta Determination Of Cvocs, Emily M. Sheehan, Matt A. Limmer, Philipp Mayer, Ulrich Gosewinkel Karlson, Joel Gerard Burken Mar 2012

Time-Weighted Average Spme Analysis For In Planta Determination Of Cvocs, Emily M. Sheehan, Matt A. Limmer, Philipp Mayer, Ulrich Gosewinkel Karlson, Joel Gerard Burken

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

The Potential of Phytoscreening for Plume Delineation at Contaminated Sites Has Promoted Interest in Innovative, Sensitive Contaminant Sampling Techniques. Solid-Phase Microextraction (SPME) Methods Have Been Developed, Offering Quick, Undemanding, Noninvasive Sampling Without the Use of Solvents. in This Study, Time-Weighted Average SPME (TWA-SPME) Sampling Was Evaluated for in Planta Quantification of Chlorinated Solvents. TWA-SPME Was Found to Have Increased Sensitivity over Headspace and Equilibrium SPME Sampling. using a Variety of Chlorinated Solvents and a Polydimethylsiloxane/carboxen (PDMS/CAR) SPME Fiber, Most Compounds Exhibited Near Linear or Linear Uptake over the Sampling Period. Smaller, Less Hydrophobic Compounds Exhibited More Nonlinearity Than Larger, More …


Revisions To Tilt-Up Concrete Building Design: The Backstory Behind Changes Encompassed In 2009 International Building Code, John W. Lawson Mar 2012

Revisions To Tilt-Up Concrete Building Design: The Backstory Behind Changes Encompassed In 2009 International Building Code, John W. Lawson

Architectural Engineering

The 2009 International Building Code (IBC) has in its scope some significant revisions that greatly affect the design of tilt-up concrete buildings, but to the lay engineer it appears that some of these provisions are a step backwards. With the IBC’s referencing standards including ACI 318-08 (concrete) and the 2008 NDS SDPWS (timber), these documents have significant changes that become effective with the adoption of the IBC. We as engineers expect building codes to advance the state of the art with each successive edition. The 2009 International Building Code (IBC) and the Building Code Requirements for Structural Concrete (ACI 318-08) …


Quantifying The Life Cycle Benefits Of Performance-Based Design In Sustainable Design, David Isaac Carmona Mar 2012

Quantifying The Life Cycle Benefits Of Performance-Based Design In Sustainable Design, David Isaac Carmona

Master's Theses

ABSTRACT

Quantifying the Life Cycle Benefits of Performance-Based Design in Sustainable Design

David Carmona

For this thesis, a method is developed and tested for use with performance based design to quantify the sustainable and financial benefits of designing buildings to a structural performance level higher than Life-Safety. This paper starts to answer the question, “which would be a better investment: build structures to a performance level of Immediate Occupancy (IO) with the likelihood of less damage and downtime after an earthquake or continue to build to the building code’s implied minimum performance level of Life-Safety (LS)?”

An ASCE 7-05 designed …


Finite-Element Limit Analysis Of The Tucker High School Gymnasium Roof Failure, Peter T. Laursen, Edmond P. Saliklis Mar 2012

Finite-Element Limit Analysis Of The Tucker High School Gymnasium Roof Failure, Peter T. Laursen, Edmond P. Saliklis

Architectural Engineering

The Randolph Tucker High School gymnasium roof failure of 1970 has received much scholarly attention. This study will provide a conclusion to a large body of previously published works by means of limit state analysis of the roof failure using state of the art parametric finite-element modeling. Parametric modeling within a general purpose finite-element analysis program allows for extremely rapid changes to the model because key terms are objects or parameters that can be adjusted internally by the program, rather than laboriously entered by the user. The failure of the roof was investigated by means of a limit state analysis, …


The Bridge Newsletter Spring 2012, Missouri University Of Science And Technology Feb 2012

The Bridge Newsletter Spring 2012, Missouri University Of Science And Technology

The Bridge Newsletter

-Light-weight foam could cushion expensive bridge repairs
-New Chancellor
-The house of the future today
-High-tech approach to project management


Spectral Amplification Of Seismic Motion Travelling Through Natural Sand Deposits, Pradipta Chakrabortty, Radu Popescu Jan 2012

Spectral Amplification Of Seismic Motion Travelling Through Natural Sand Deposits, Pradipta Chakrabortty, Radu Popescu

Architectural Engineering

Guidelines for seismic spectral amplification are provided in current building codes based on soil strength/stiffness by means of seismic site class. However, current codes do not make a difference between fully saturated and unsaturated soil deposits and do not account for effects of soil heterogeneity on seismic amplification. This study investigates the effect of natural small scale soil heterogeneity and degree of saturation on spectral amplification by means of transient nonlinear finite element analyses. Only cohesionless soil (sand) is considered in this study. The effects of presence of a structure are also studied for soils with two different relative densities. …


Ua61/3 Wku Nursing & Physical Therapy - The Medical Center - Wku Health Sciences Complex, Wku Health & Human Services Jan 2012

Ua61/3 Wku Nursing & Physical Therapy - The Medical Center - Wku Health Sciences Complex, Wku Health & Human Services

WKU Administration Documents

Fundraising brochure regarding The Medical Center – WKU Health Sciences Complex constructed from 2012 through 2014. Features architectural renderings of each floor.


Topological Theory In Bioconstructivism, John Shannon Hendrix Jan 2012

Topological Theory In Bioconstructivism, John Shannon Hendrix

Architecture, Art, and Historic Preservation Faculty Publications

In the essay “Landscapes of Change: Boccioni’s Stati d’animo as a General Theory of Models,” in Assemblage 19, 1992, Sanford Kwinter proposed a number of theoretical models which could be applied to computer-generated forms in Bioconstructivism. These included topological theory, epigenesis, the epigenetic landscape, morphogenesis, catastrophe and catastrophe theory. Topological theory entails transformational events or deformations in nature which introduce discontinuities into the evolution of a system. Epigenesis entails the generation of smooth landscapes, in waves or the surface of the earth, for example, formed by complex underlying topological interactions. The epigenetic landscape is the smooth forms of relief which …


An Adaptive Utility Interactive Photovoltaic System Based On A Flexible Switch Matrix To Optimize Performance In Real-Time, Mahmoud Alahmad, Mohamed Amer Chaaban, Siu Kit Lau, Jonathan Shi, Jill Neal Jan 2012

An Adaptive Utility Interactive Photovoltaic System Based On A Flexible Switch Matrix To Optimize Performance In Real-Time, Mahmoud Alahmad, Mohamed Amer Chaaban, Siu Kit Lau, Jonathan Shi, Jill Neal

Durham School of Architectural Engineering and Construction: Faculty Publications

Reconfigurable architectures are of great interest to system designers to improve the system’s operation and efficiency. In this paper, we propose an adaptive utility interactive photovoltaic (PV) system based on a novel Flexible Switch array Matrix topology. This proposed system maximizes the generated power in real-time in response to operational conditions such as shading, soiling, mismatches, and module failure among others. The proposed system is a compromise in the utilization of power conditioning equipment to maximize energy capture and system efficiency. Simulation results demonstrate an average 13% improvement in efficiency when compared with the central inverter topology performance. A prototype …


Application Of Drum-Buffer-Rope Methodology In Scheduling Of Healthcare System, Arefeh Mohammadi, Emmanuel S. Eneyo Jan 2012

Application Of Drum-Buffer-Rope Methodology In Scheduling Of Healthcare System, Arefeh Mohammadi, Emmanuel S. Eneyo

Durham School of Architectural Engineering and Construction: Faculty Publications

Theory of constraints (TOC) is a management philosophy that seeks to increase throughput (efficiency or performance) of the system by identifying those processes that are constraining the system bottlenecks. There have been very few profound studies of TOC in health care systems. In order to fill this gap, this study was conducted to determine how healthcare systems are utilizing components of TOC to schedule operations and what results are being obtained. This is done by using a patient flow model for a radiotherapy section of a hospital. The drum-buffer-rope (DBR) was used as the methodology for scheduling this flow. Successful …


Effects Of Inclusion Shapes Within Rigid Porous Materials On Acoustic Performance, Hyun Hong, Siu-Kit Lau Jan 2012

Effects Of Inclusion Shapes Within Rigid Porous Materials On Acoustic Performance, Hyun Hong, Siu-Kit Lau

Durham School of Architectural Engineering and Construction: Faculty Publications

The present study investigates the influence of various shapes of inclusions having same volume embedded in a porous rigid material. Previous studies showed improvement of the broadband sound absorption with particular shapes of inclusions. However, different volumes of the inclusions have been considered; therefore, the bulk densities are not the same for comparison. The present study extends the investigations of inclusions in porous materials with same volume (or bulk density) to eliminate the influence by the change of bulk density. The effects of shape will be discussed. Finite element modeling will be used for this study. Total four different shapes: …


Effects Of Roof Pitch On Air Flow And Heating Load Of Sealed And Vented Attics For Gable-Roof Residential Buildings, Shimin Wang, Zhigang Shen Jan 2012

Effects Of Roof Pitch On Air Flow And Heating Load Of Sealed And Vented Attics For Gable-Roof Residential Buildings, Shimin Wang, Zhigang Shen

Durham School of Architectural Engineering and Construction: Faculty Publications

Pitch value is an important consideration in residential gable roof design and construction. However, how roof pitch, coupled with air flows in attic space, affects the energy performance of building attics has been barely investigated. In this paper, a 2D unsteady computational fluid dynamics (CFD) model is employed to investigate the effects of roof pitch on air flow and heating load of both sealed and vented attics for gable-roof residential buildings. The simulation results show that air flow in the sealed attics is steady and asymmetric, while that in the vented attics is a combination of an essentially symmetric base …