Full-Text Articles in Architectural Engineering

Interdisciplinary Capstone Design: Architects, Structural Engineers, And Construction Managers, James Guthrie, Allen Estes, Jill Nelson, Brent Nuttall Jun 2012

Interdisciplinary Capstone Design: Architects, Structural Engineers, And Construction Managers, James Guthrie, Allen Estes, Jill Nelson, Brent Nuttall

Architectural Engineering

The College of Architecture and Environmental Design at California Polytechnic State University in San Luis Obispo is the only college in the nation that has departments of Architecture, Architectural Engineering, Construction Management and Landscape Architecture in the same college. The institution has a 60 year tradition of collaboration between the engineering, architecture and construction disciplines, particularly at the lower division level. To enhance this collaboration, the college committed to providing an upper division, interdisciplinary experience to every student in the form of a project based, team oriented five unit studio laboratory that every student would take. The course is now …


College And Industry Partnerships: The Samé, Tanzania Polytechnic And Weld Quality, Craig Baltimore, Allen C. Estes Jun 2012

College And Industry Partnerships: The Samé, Tanzania Polytechnic And Weld Quality, Craig Baltimore, Allen C. Estes

Architectural Engineering

No abstract provided.


Ten Years Of Abet Ec 2000: One Person's Reflections, Allen Estes Jun 2012

Ten Years Of Abet Ec 2000: One Person's Reflections, Allen Estes

Architectural Engineering

ABET accreditation criteria changed substantially at the turn of the century changing from a prescriptive, curricular-based standard to an outcomes-based approach for accreditation. The new system named Engineering Criteria (EC) 2000 required engineering programs to consult with their constituencies to establish program objectives and outcomes that define what their graduates will attain several years after graduation and at the time of graduation, respectively. The accreditation process involves assessing the degree to which graduates are attaining these outcomes and objectives and using the results to make changes and continuously improve the program. Most engineering programs have now been through two cycles …


Multinomial Logistic Regression Model For Single-Vehicle And Multivehicle Collisions On Urban U.S. Highways In Arkansas, Ghulam Bham, Bhanu S. Javvadi, Uday R.R. Manepalli Jun 2012

Multinomial Logistic Regression Model For Single-Vehicle And Multivehicle Collisions On Urban U.S. Highways In Arkansas, Ghulam Bham, Bhanu S. Javvadi, Uday R.R. Manepalli

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

Multivariate analysis can be used to identify the effects of several factors on the causes of a crash compared with univariate analysis. This paper uses a multivariate-analysis technique, the multinomial logistic regression (MLR) model, to examine the differences in crash-contributing factors for six collision types for both divided- and undivided-highway nonjunctions, given that a crash has occurred. Multinomial logistic regression was used to investigate (1) single-vehicle and (2) multivehicle collisions, which included (1) angular, (2) head-on, (3) rear-end, (4) sideswipe-same-direction, and (5) sideswipe-opposite-direction collisions. the risks associated with different collision types were found to be significantly influenced by various vehicle …


Development And Testing Of Chemically-Based Self-Consolidating Concrete, Mahdi Arezoumandi, Mark Ezzell, Jeffery S. Volz Jun 2012

Development And Testing Of Chemically-Based Self-Consolidating Concrete, Mahdi Arezoumandi, Mark Ezzell, Jeffery S. Volz

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

Self-consolidating concrete (SCC) has the potential to significantly reduce costs associated with concrete construction. SCC is a highly flowable, Non segregating concrete that has a variety of advantages over conventional concrete (CC). However, SCC is not without its problems, which can include increased creep and shrinkage, as well as decreased bond and shear strength. the goal of this research project was to evaluate the creep, shrinkage, and shear behavior of a chemically Based SCC mix. One of the benefits of a chemically Based approach is the potential to eliminate the negative side effects of many SCC mixes. the investigation included …


High-Volume Fly Ash Concrete For Sustainable Construction, Jeffery S. Volz Jun 2012

High-Volume Fly Ash Concrete For Sustainable Construction, Jeffery S. Volz

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

With worldwide production of fly ash approaching 800 million tons annually, increasing the amount of fly ash used in concrete will remove more material from the solid waste stream and reduce the amount ending up in landfills. However, most specifications limit the amount of cement replacement with fly ash to less than 25 or 30%. Concrete with fly ash replacement levels of at least 50% - referred to as high-volume fly ash (HVFA) concrete - offers a potential green solution. the following study investigated the structural performance of HVFA concrete compared to conventional Portland-cement concrete. Specifically, the research examined both …


Performance-Based Analysis Of A Reinforced Concrete Shear Wall Building, Garrett Richard Hagen Jun 2012

Performance-Based Analysis Of A Reinforced Concrete Shear Wall Building, Garrett Richard Hagen

Master's Theses

PERFORMANCE-BASED ANALYSIS OF A REINFORCED CONCRETE SHEAR WALL BUILDING

Garrett Richard Hagen

In this thesis, a special reinforced concrete shear wall building was designed per ASCE 7-05, and then the performance was investigated using the four analysis procedures outlined in ASCE 41-06. The proposed building was planned as a 6-story office building in San Francisco, CA. The structural system consisted of a two-way flat plate and reinforced concrete columns for gravity loads and slender structural walls for seismic loads. The mathematical building models utilized recommendations from ASCE 41-06 and first-principle mechanics. Moment-curvature analysis and fiber cross-section elements were used in …


Residential Energy Recovery Radiant Heat System, Scott Sharp May 2012

Residential Energy Recovery Radiant Heat System, Scott Sharp

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

Energy recovery systems aim to recover waste energy that is normally lost to the environment. Waste energy comes in a variety of forms. Many processes involving building HVAC involves transferring energy from one working fluid to another. Governing codes put strict requirements on ventilation requirements for various occupancy types. Increased ventilation demands more from the HVAC equipment since outdoor air (ventilation air) is being brought into the building and requires tempering in order to retain occupant comfort. The energy required to temper this air increases as ventilation rates increase. Many commercial buildings have implemented exhaust air energy recovery, or runaround …


Electromagnetic Harvesting To Power Energy Management Sensors In The Built Environment, Evans Sordiashie May 2012

Electromagnetic Harvesting To Power Energy Management Sensors In The Built Environment, Evans Sordiashie

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

Recently, a growing body of scholarly work in the field of energy conservation is focusing on the implementation of energy management sensors in the power distribution system. Since most of these sensors are either battery operated or hardwired to the existing power distribution system, their use comes with major drawbacks. Battery maintenance and associated labor costs can make implementing sensors very expensive. Although hardwired sensors require very little post-installation maintenance, any energy savings they may procure is offset by the amount of energy expended during the course of the sensors normal operation. In response to these energy challenges, this thesis …


Damage Detection In Metamorphic Stone Blocks Utilizing Impact-Echo Testing And Modal Analysis, Alexander C. Jording May 2012

Damage Detection In Metamorphic Stone Blocks Utilizing Impact-Echo Testing And Modal Analysis, Alexander C. Jording

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

Existing buildings decay with the passage of time, and as a result, continually require maintenance or rehabilitation. When considering existing structures, testing is often necessary to complete structural analysis in preparation for rehabilitation or repair. Non-destructive testing provides a structural assessment method applicable to a variety of materials and structures. The hypothesis of this research is that impact-echo testing, one of the many NDT techniques, can be adopted to develop a reliable and standardized method to assess the condition of rectangular metamorphic stones. After the baseline material parameters and general response to impact-echo testing were established, a novel method to …


Assessing The Engineering Performance Of Affordable Net-Zero Energy Housing, Jordan P. Wallpe May 2012

Assessing The Engineering Performance Of Affordable Net-Zero Energy Housing, Jordan P. Wallpe

Purdue Polytechnic Masters Theses

The purpose of this research was to evaluate affordable technologies that are capable of providing attractive, cost-effective energy savings to the housing industry. The research did so by investigating the 2011 Solar Decathlon competition, with additional insight from the Purdue INhome. Insight from the Purdue INhome verified the importance of using a three step design process to design a net-zero energy building. In addition, energy consumption values of the INhome were used to compare and contrast different systems used in other houses.

Evaluation of unbiased competition contests gave a better understanding of how a house can realistically reach net-zero. Upon …


Structural Performance Of Reinforced Concrete Flat Plat Buildings Subjected To Fire, Sara Jean George May 2012

Structural Performance Of Reinforced Concrete Flat Plat Buildings Subjected To Fire, Sara Jean George

UNLV Theses, Dissertations, Professional Papers, and Capstones

Reinforced concrete structures are typically considered to have inherent resistance to fire. However, several concrete structures around the world have experienced partial or total collapse under fire. Reinforced concrete flat-plate is a type of structural system widely used for office and residential buildings. Flat plate construction is prone to punching shear failure at slab-column connections which may lead to a catastrophic progressive collapse. The slabs of flat-plates generally have very thin concrete cover leaving steel reinforcement more sensitive to thermal loads. Little is known in the engineering community about the structural performance of flat-plate structures subjected to fire. Through a …


A Composite Structural Steel And Prestressed Concrete Beam For Building Floor Systems, Nathan Dewit Apr 2012

A Composite Structural Steel And Prestressed Concrete Beam For Building Floor Systems, Nathan Dewit

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

Precast prestressed concrete beams, such as rectangular and inverted tee beam, currently used in residential and commercial buildings are deep, heavy, and limited to span-to-depth ratios of 15. The research proposes a composite structural steel and prestressed concrete beam that is shallow, light, easy to produce and erect, and able to achieve a span-to-depth ratio of 24. The proposed beam is designed to be used with precast columns, hollow-core planks, and a cast-in-place topping to create a moment-resisting floor system that minimizes the need for shear walls. The goal of this system is to eliminate as many of the limitations …


Monotonic Behavior Of Mississippi River Valley Silt In Triaxial Compression, Shuying Wang, Ronaldo Luna Apr 2012

Monotonic Behavior Of Mississippi River Valley Silt In Triaxial Compression, Shuying Wang, Ronaldo Luna

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

The static behavior of Mississippi River Valley silt was characterized using triaxial compression testing. Silt specimens, especially over consolidated ones, showed dilation behavior. There was no unique critical state among specimens with different over consolidation ratios (OCRs). with OCRs of 1, 2, and 8, the specimens exhibited normal behavior and dilated more as effective consolidation pressure dropped. However, for an OCR of 4, the specimens showed opposite behavior and dilated more as effective consolidation pressure rose. the friction angle of the silt was computed on the basis of several failure criteria, and the limiting strain was found to be the …


A Comparative Study Of Three Feedback Devices For Residential Real-Time Energy Monitoring, Mahmoud Alahmad, Patrick G. Wheeler, Joshua Eiden, Adam Brumbaugh Apr 2012

A Comparative Study Of Three Feedback Devices For Residential Real-Time Energy Monitoring, Mahmoud Alahmad, Patrick G. Wheeler, Joshua Eiden, Adam Brumbaugh

Durham School of Architectural Engineering and Construction: Faculty Publications

Residential energy consumption accounts for 21% of the total electricity use in the United States. Unfortunately, research indicates that almost 41% of this power is wasted. Changing the way that consumers use energy may be important in reducing home energy consumption. This paper looks at whether the implementation of certain real-time energy monitors has an impact on the residential rate of energy consumption in a metropolitan area with relatively low electricity rates. In the following case study, 151 Omaha residences were equipped with two variants of the Aztech In-Home Display (Aztech) as well as the Blue Line Power Cost Monitor …


A Numerical Investigation Of Two Phase Solar-Collector Pipe, Seyyed Hashem Abedini Apr 2012

A Numerical Investigation Of Two Phase Solar-Collector Pipe, Seyyed Hashem Abedini

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

In the United States, major portions of the annual electrical and primary energy are consumed for buildings. To help reduce the energy consumption of non-renewable energy sources, this study investigates a new technology for harvesting solar energy using a boiling-condensing cycle with water in a solar collector. The fluid circulation is under natural forced convection. A solar collector is made of a black lacquer copper with 2 meters in length is used. The design of the system is presented to simulate heat transfer rate in a cold climate an average daily solar irradiation of 4.5kWh/m2/day, e.g. for Omaha …


The Assessment Of High Dynamic Range Luminance Measurements With Led Lighting, Yulia I. Tyukhova Apr 2012

The Assessment Of High Dynamic Range Luminance Measurements With Led Lighting, Yulia I. Tyukhova

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

This research investigates whether a High Dynamic Range Imaging (HDRI) technique can accurately capture luminance values of a single LED chip. Previous studies show that a digital camera with exposure capability can be used as a luminance mapping tool in a wide range of luminance values with an accuracy of 10%. Previous work has also demonstrated the ability of HDRI to capture a rapidly-changing lighting environment with the sun. However these publications don’t investigate HDRI’s ability to capture a bright light source with a narrow light distribution (LED lighting).

Some of the existing concerns in LED technology today include low …


Factors Influencing Crack-Induced Tensile Strength Of Compacted Soil, Tae Hyung Kim, Tae Hoon Kim, Gi Chun Kang, Louis Ge Mar 2012

Factors Influencing Crack-Induced Tensile Strength Of Compacted Soil, Tae Hyung Kim, Tae Hoon Kim, Gi Chun Kang, Louis Ge

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

Mode I (tensile) fracture is the most commonly observed failure in Geostructure's resulting from cracks in soil. Direct or indirect tensile tests have been used to evaluate the tensile strength of geomaterials. in this paper, the unconfined penetration device and experimental procedure were modified to reduce measurement errors. It was then used to determine the tensile strength of compacted soil. Factors influencing the tensile strength of the compacted soil, including the plasticity index, rate of loading, and size of specimen were discussed in detail, as well as its reliability. Experimental results indicated that the modified, unconfined penetration technique is sufficiently …


Time-Weighted Average Spme Analysis For In Planta Determination Of Cvocs, Emily M. Sheehan, Matt A. Limmer, Philipp Mayer, Ulrich Gosewinkel Karlson, Joel Gerard Burken Mar 2012

Time-Weighted Average Spme Analysis For In Planta Determination Of Cvocs, Emily M. Sheehan, Matt A. Limmer, Philipp Mayer, Ulrich Gosewinkel Karlson, Joel Gerard Burken

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

The Potential of Phytoscreening for Plume Delineation at Contaminated Sites Has Promoted Interest in Innovative, Sensitive Contaminant Sampling Techniques. Solid-Phase Microextraction (SPME) Methods Have Been Developed, Offering Quick, Undemanding, Noninvasive Sampling Without the Use of Solvents. in This Study, Time-Weighted Average SPME (TWA-SPME) Sampling Was Evaluated for in Planta Quantification of Chlorinated Solvents. TWA-SPME Was Found to Have Increased Sensitivity over Headspace and Equilibrium SPME Sampling. using a Variety of Chlorinated Solvents and a Polydimethylsiloxane/carboxen (PDMS/CAR) SPME Fiber, Most Compounds Exhibited Near Linear or Linear Uptake over the Sampling Period. Smaller, Less Hydrophobic Compounds Exhibited More Nonlinearity Than Larger, More …


Revisions To Tilt-Up Concrete Building Design: The Backstory Behind Changes Encompassed In 2009 International Building Code, John W. Lawson Mar 2012

Revisions To Tilt-Up Concrete Building Design: The Backstory Behind Changes Encompassed In 2009 International Building Code, John W. Lawson

Architectural Engineering

The 2009 International Building Code (IBC) has in its scope some significant revisions that greatly affect the design of tilt-up concrete buildings, but to the lay engineer it appears that some of these provisions are a step backwards. With the IBC’s referencing standards including ACI 318-08 (concrete) and the 2008 NDS SDPWS (timber), these documents have significant changes that become effective with the adoption of the IBC. We as engineers expect building codes to advance the state of the art with each successive edition. The 2009 International Building Code (IBC) and the Building Code Requirements for Structural Concrete (ACI 318-08) …


Quantifying The Life Cycle Benefits Of Performance-Based Design In Sustainable Design, David Isaac Carmona Mar 2012

Quantifying The Life Cycle Benefits Of Performance-Based Design In Sustainable Design, David Isaac Carmona

Master's Theses

ABSTRACT

Quantifying the Life Cycle Benefits of Performance-Based Design in Sustainable Design

David Carmona

For this thesis, a method is developed and tested for use with performance based design to quantify the sustainable and financial benefits of designing buildings to a structural performance level higher than Life-Safety. This paper starts to answer the question, “which would be a better investment: build structures to a performance level of Immediate Occupancy (IO) with the likelihood of less damage and downtime after an earthquake or continue to build to the building code’s implied minimum performance level of Life-Safety (LS)?”

An ASCE 7-05 designed …


Finite-Element Limit Analysis Of The Tucker High School Gymnasium Roof Failure, Peter T. Laursen, Edmond P. Saliklis Mar 2012

Finite-Element Limit Analysis Of The Tucker High School Gymnasium Roof Failure, Peter T. Laursen, Edmond P. Saliklis

Architectural Engineering

The Randolph Tucker High School gymnasium roof failure of 1970 has received much scholarly attention. This study will provide a conclusion to a large body of previously published works by means of limit state analysis of the roof failure using state of the art parametric finite-element modeling. Parametric modeling within a general purpose finite-element analysis program allows for extremely rapid changes to the model because key terms are objects or parameters that can be adjusted internally by the program, rather than laboriously entered by the user. The failure of the roof was investigated by means of a limit state analysis, …


The Bridge Newsletter Spring 2012, Missouri University Of Science And Technology Feb 2012

The Bridge Newsletter Spring 2012, Missouri University Of Science And Technology

The Bridge Newsletter

-Light-weight foam could cushion expensive bridge repairs
-New Chancellor
-The house of the future today
-High-tech approach to project management


Spectral Amplification Of Seismic Motion Travelling Through Natural Sand Deposits, Pradipta Chakrabortty, Radu Popescu Jan 2012

Spectral Amplification Of Seismic Motion Travelling Through Natural Sand Deposits, Pradipta Chakrabortty, Radu Popescu

Architectural Engineering

Guidelines for seismic spectral amplification are provided in current building codes based on soil strength/stiffness by means of seismic site class. However, current codes do not make a difference between fully saturated and unsaturated soil deposits and do not account for effects of soil heterogeneity on seismic amplification. This study investigates the effect of natural small scale soil heterogeneity and degree of saturation on spectral amplification by means of transient nonlinear finite element analyses. Only cohesionless soil (sand) is considered in this study. The effects of presence of a structure are also studied for soils with two different relative densities. …


2012 Scholarly Productivity Report, Missouri University Of Science And Technology Jan 2012

2012 Scholarly Productivity Report, Missouri University Of Science And Technology

Civil, Architectural and Environmental Engineering Scholarly Productivity Reports

No abstract provided.


Effects Of Nano-Copper(Ii) Oxide And Nano- Magnesium Oxide Particles On Activated Sludge, Guoqiang Liu, Jianmin Wang Jan 2012

Effects Of Nano-Copper(Ii) Oxide And Nano- Magnesium Oxide Particles On Activated Sludge, Guoqiang Liu, Jianmin Wang

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

Effects of nano-copper (II) oxide (nano-CuO) and nano-magnesium oxide (nano-MgO) particles on activated sludge endogenous respiration (aerobic digestion), biochemical oxygen demand (BOD) biodegradation, and nitrification were investigated through respiration rate measurement. for comparison, the effects of Cu (II) and Mg (II) ions on activated sludge were also studied. Results indicated that soluble Cu (II) has half maximum inhibitory concentration (IC50) values of 19, 5.5, 53, and 117 mg Cu/L for endogenous respiration, BOD biodegradation, ammonium oxidation, and nitrite oxidation, respectively. However, nano-CuO only inhibited BOD biodegradation at 240 mg Cu/L or more, and its associated toxicity was primarily caused by …


From The Personal To The Communal - Support For An Evolutionary Urban System, Noel Brady Jan 2012

From The Personal To The Communal - Support For An Evolutionary Urban System, Noel Brady

Conference papers

A short discussion towards a model for the future of urban and interurban development. From the personal tot he communal argues for a futurist city that is an organic physiological time filled environment.


Ua61/3 Wku Nursing & Physical Therapy - The Medical Center - Wku Health Sciences Complex, Wku Health & Human Services Jan 2012

Ua61/3 Wku Nursing & Physical Therapy - The Medical Center - Wku Health Sciences Complex, Wku Health & Human Services

WKU Administration Documents

Fundraising brochure regarding The Medical Center – WKU Health Sciences Complex constructed from 2012 through 2014. Features architectural renderings of each floor.


Long-Term Performance Of Passive Materials For Removal Of Ozone From Indoor Air, C. J. Cros, Glenn C. Morrison, J. A. Siegel, R. L. Corsi Jan 2012

Long-Term Performance Of Passive Materials For Removal Of Ozone From Indoor Air, C. J. Cros, Glenn C. Morrison, J. A. Siegel, R. L. Corsi

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

The health effects associated with exposure to ozone range from respiratory irritation to increased mortality. in this paper, we explore the use of three green building materials and an activated carbon (AC) mat that remove ozone from indoor air. We studied the effects of long-term exposure of these materials to real environments on ozone removal capability and pre- and post-ozonation emissions. a field study was completed over a 6-month period, and laboratory testing was intermittently conducted on material samples retrieved from the field. the results show sustained ozone removal for all materials except recycled carpet, with greatest ozone deposition velocity …


An Improved Prediction Model For Spacecraft Damage Following Orbital Debris Impact, Joel E. Williamsen, William P. Schonberg Jan 2012

An Improved Prediction Model For Spacecraft Damage Following Orbital Debris Impact, Joel E. Williamsen, William P. Schonberg

Civil, Architectural and Environmental Engineering Faculty Research & Creative Works

This paper offers a new set of 'generic', data-Based hole size and crank length prediction models for spherical orbital debris particles impacting multi-plate targets at velocities up to ~12 km/s. the equations are applicable to a wide variety of spacecraft target configurations, but are limited to hole sizes above, but relatively near, the ballistic limit of the impacting particles. Additional work is underway to expand these models to diameters farther above the ballistic limit for the described shield types.