Open Access. Powered by Scholars. Published by Universities.®

Architectural Engineering Commons™

Open Access. Powered by Scholars. Published by Universities.®

University of Nebraska - Lincoln

Discipline
Keyword
Publication Year
Publication

Articles 181 - 210 of 308

Full-Text Articles in Architectural Engineering

Air Change Rate Vs Airflow Pathway: Bioaerosol Containment And Removal In Patient Rooms, Kevin R. Grosskopf Jan 2015

Air Change Rate Vs Airflow Pathway: Bioaerosol Containment And Removal In Patient Rooms, Kevin R. Grosskopf

Durham School of Architectural Engineering and Construction: Faculty Publications

Recent studies have shown that higher air change rates may have the unintended consequence of creating turbulent airflows that entrain high concentrations of infectious particles within the breathing zone, and possibly, breakdown pressure relationships necessary to contain the spread of infectious particles to other clinical spaces.


Ventilation Rates And Airflow Pathways In Patient Rooms: A Case Study Of Bioaerosol Containment And Removal, Ehsan S. Mousavi, Kevin R. Grosskopf Jan 2015

Ventilation Rates And Airflow Pathways In Patient Rooms: A Case Study Of Bioaerosol Containment And Removal, Ehsan S. Mousavi, Kevin R. Grosskopf

Durham School of Architectural Engineering and Construction: Faculty Publications

Most studies on the transmission of infectious airborne disease have focused on patient room air changes per hour (ACH) and how ACH provides pathogen dilution and removal. The logical but mostly unproven premise is that greater air change rates reduce the concentration of infectious particles and thus, the probability of airborne disease transmission. Recently, a growing body of research suggests pathways between pathogenic source (patient) and control (exhaust) may be the dominant environmental factor. While increases in airborne disease transmission have been associated with ventilation rates below 2 ACH, comparatively less data are available to quantify the benefits of higher …


Adaptive Predictive Functional Controller, Fadi Alsaleem, Arvind Rao Jan 2015

Adaptive Predictive Functional Controller, Fadi Alsaleem, Arvind Rao

Durham School of Architectural Engineering and Construction: Faculty Publications

A controller device and a method for controlling a system that utilizes an adaptive mechanism to self-learn the system char acteristics and incorporates this adaptive self-learning ability to predict a control parameter correctly to provide precise control of a system component.


An Adaptive Photovoltaic Topology To Overcome Shading Effect In Pv Systems, Mohamed Amer Chaaban, Lana El Chaar, Mahmoud Alahmad Jan 2015

An Adaptive Photovoltaic Topology To Overcome Shading Effect In Pv Systems, Mohamed Amer Chaaban, Lana El Chaar, Mahmoud Alahmad

Durham School of Architectural Engineering and Construction: Faculty Publications

Shading in photovoltaic systems can cause many undesired effects.When shading occurs, the power generated from the PV system is much less than nominal power, increasing the electrical mismatching losses between PV system components. Active research to address this power loss focuses on static and adaptive systems.This paper addresses an adaptive system solution and proposes a new method to adaptively overcome losses due to shading during low radiation conditions. In addition, a statistical analysis for choosing the most feasible and efficient configuration for the system size is presented. The proposed system has been validated under shade conditions in a simulation and …


Building Envelope And Interior Grading Systems And Methods, Fadi Mohammad Alsaleem Jan 2015

Building Envelope And Interior Grading Systems And Methods, Fadi Mohammad Alsaleem

Durham School of Architectural Engineering and Construction: Faculty Publications

A difference module determines differences between an out door ambient temperature and an indoor temperature, deter mines a first average of the differences, and determines a second average of the differences. A storing module stores a first data point, the first data point including the first average and a first total run time of a heating, ventilation, and/or air conditioning (HVAC) system, and stores a second data point, the second data point including the second average and a second total run time of the HVAC system. A fitting module fits a line to the first and second data points. An …


A Review Of Approaches For Sensing, Understanding, And Improving Occupancy-Related Energy-Use Behaviors In Commercial Buildings, Hamed Nabizadeh Rafsanjani, Changbum R. Ahn, Mahmoud Alahmad Jan 2015

A Review Of Approaches For Sensing, Understanding, And Improving Occupancy-Related Energy-Use Behaviors In Commercial Buildings, Hamed Nabizadeh Rafsanjani, Changbum R. Ahn, Mahmoud Alahmad

Durham School of Architectural Engineering and Construction: Faculty Publications

Buildings currently account for 30–40 percent of total global energy consumption. In particular, commercial buildings are responsible for about 12 percent of global energy use and 21 percent of the United States’ energy use, and the energy demand of this sector continues to grow faster than other sectors. This increasing rate therefore raises a critical concern about improving the energy performance of commercial buildings. Recently, researchers have investigated ways in which understanding and improving occupants’ energy-consuming behaviors could function as a cost-effective approach to decreasing commercial buildings’ energy demands. The objective of this paper is to present a detailed, up-to-date …


Use Of Fiber-Reinforced Cements In Masonry Construction And Structural Rehabilitation, Ece Erdogmus Jan 2015

Use Of Fiber-Reinforced Cements In Masonry Construction And Structural Rehabilitation, Ece Erdogmus

Durham School of Architectural Engineering and Construction: Faculty Publications

The use of fiber reinforcement in traditional concrete mixes has been extensively studied and has been slowly finding its regular use in practice. In contrast, opportunities for the use of fibers in masonry applications and structural rehabilitation projects (masonry and concrete structures) have not been as deeply investigated, where the base matrix may be a weaker cementitious mixture. This paper will summarize the findings of the author’s research over the past 10 years in these particular applications of fiber reinforced cements (FRC). For masonry, considering both mortar and mortar-unit bond characteristics, a 0.5% volume fraction of micro fibers in type …


Designing Acoustics For Linguistically Diverse Classrooms: Effects Of Background Noise, Reverberation And Talker Foreign Accent On Speech Comprehension By Native And Non-Native English-Speaking Listeners, Z. Ellen Peng Dec 2014

Designing Acoustics For Linguistically Diverse Classrooms: Effects Of Background Noise, Reverberation And Talker Foreign Accent On Speech Comprehension By Native And Non-Native English-Speaking Listeners, Z. Ellen Peng

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

The current classroom acoustics standard (ANSI S12.60-2010) recommends core learning spaces not to exceed background noise level (BNL) of 35 dBA and reverberation time (RT) of 0.6 second, based on speech intelligibility performance mainly by the native English-speaking population. Existing literature has not correlated these recommended values well with student learning outcomes. With a growing population of non-native English speakers in American classrooms, the special needs for perceiving degraded speech among non-native listeners, either due to realistic room acoustics or talker foreign accent, have not been addressed in the current standard. This research seeks to investigate the effects of BNL …


Determining Thresholds Of Annoyance To Tones In Noise, Jennifer Marie Francis Dec 2014

Determining Thresholds Of Annoyance To Tones In Noise, Jennifer Marie Francis

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

Building services equipment often produce noise with prominent tones that can lead to complaints from occupants in the built environment. Previous studies have investigated human perception to tones in noise but it is still unclear at what threshold of prominence these tones lead to human annoyance. The goal of this research is to apply two different methods towards defining thresholds of annoyance to two tonal frequencies: 125 Hz and 500 Hz. In Method I – Direct Assessment with Task, subjects are exposed to 10 minutes of broadband noise with a tonal frequency set at a certain level of prominence while …


Assessment Of Noise-Induced Annoyance By Tones In Noise From Building Mechanical Systems, Joonhee Lee, Lily M. Wang Nov 2014

Assessment Of Noise-Induced Annoyance By Tones In Noise From Building Mechanical Systems, Joonhee Lee, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

Prominent tones in noise generated by mechanical equipment in buildings can cause complaints from occupants in buildings. The ISO 1996-2 and ANSI S1.13 standards describe methodologies and metrics to quantify tonality perception, but the influence of tones in noise on human annoyance and performance is not fully understood yet. This paper investigates annoyance responses of humans while exposed to background noise with tonal components. Twenty participants completed digit span tasks while exposed to noise signals with differing levels of tones and overall loudness. Subjects were also asked to rate their annoyance after completing tasks under each noise signal. The subjective …


The Impact Of Building Acoustics On Speech Comprehension And Student Achievement, Lily M. Wang Nov 2014

The Impact Of Building Acoustics On Speech Comprehension And Student Achievement, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

The movement for improved classroom acoustics has primarily been grounded on studies that show how building acoustics (i.e. background noise levels and room reverberation) affect speech intelligibility, as determined by speech recognition tests. What about actual student learning, though? If students do not understand each spoken word in the classroom perfectly, can they still manage to achieve high scholastic success? This presentation will review two recent studies conducted at the University of Nebraska – Lincoln, linking classroom acoustic conditions to student learning outcomes and speech comprehension (rather than simply recognition). In the first, acoustic measurements in two public school districts …


Effects Of Room Acoustics On Comprehension Of Foreign-Accented Speech By Native And Non-Native English-Speaking Listeners, Zhao Peng, Kristin E. Hanna, Brenna N. Boyd, Lily M. Wang Nov 2014

Effects Of Room Acoustics On Comprehension Of Foreign-Accented Speech By Native And Non-Native English-Speaking Listeners, Zhao Peng, Kristin E. Hanna, Brenna N. Boyd, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

In a previous study by the authors, reverberation time (RT) and background noise level (BNL) were both found to have negative effects on native and non-native English-speaking listeners in comprehending English speech produced by native American-English-speaking talkers. Comprehension scores were adjusted for listeners’ baseline English proficiency levels. In the present study, instead of native English-speaking talkers, two native Mandarin Chinese talkers (one male, one female) with similar English spoken proficiency were recruited to produce the same speech materials used in the previous study. A similar methodology was adopted to conduct speech comprehension tests on three groups of listeners: 1) native …


Determining Annoyance Thresholds Of Tones In Noise, Jennifer M. Francis, Joonhee Lee, Lily M. Wang Jul 2014

Determining Annoyance Thresholds Of Tones In Noise, Jennifer M. Francis, Joonhee Lee, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

Building services equipment often produces noise signatures with significant tones in them that can lead to complaints in the built environment. Previous studies have investigated prominence levels of assorted tonal frequencies, but it is still unclear what prominence of the tones across varying tonal frequencies can lead to human annoyance. This project seeks to apply two different methods towards defining annoyance thresholds of tones in noise at two tonal frequencies: 125 Hz and 500 Hz. In the first, subjects are asked to perform a task, while exposed to ten minutes of a broadband noise spectrum with a specific level of …


Effects Of Polyethylene Terephthalate Fibers In The Water Resistance Of Compressed Stabilized Earth Blocks., Ebrima Colley May 2014

Effects Of Polyethylene Terephthalate Fibers In The Water Resistance Of Compressed Stabilized Earth Blocks., Ebrima Colley

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

This research project focuses on investigating the effects of synthetic fibers (PET) and amount of cement stabilization on the water absorption, water surface erosion, and wet compressive strength of the compressed stabilized earth blocks (CSEB). The use of locally available soils blended with fibers and cement was investigated to obtain a design mix for compressed stabilized earth blocks capable of staying intact in wet and humid regions in the world (i.e. regions with annual rainfall of over 50 in). Blocks with varying cement percentages of 5, 8, 10, and 15% by weight were produced with 3 specimens each, with and …


Energy Benefits Of Different Dedicated Outdoor Air Systems Configurations In Various Climates, Shihan Deng May 2014

Energy Benefits Of Different Dedicated Outdoor Air Systems Configurations In Various Climates, Shihan Deng

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

Dedicated Outdoor Air Systems (DOAS) are proven to be beneficial in many practices. However, not all DOAS configurations under different climates provide the same benefits. This study presents a simulation on evaluating various energy saving benefits of different DOAS configurations among diverse climate zones of commercial buildings in the United States.

Three DOAS configurations in a medium office building are simulated in this study: (1) fan-coil units (FCUs) as terminal units with a DOAS unit supplying conditioned outdoor air (OA) to each FCU intake; (2) FCUs with a DOAS unit supplying conditioned OA directly to each occupied space; and (3) …


On A Combined Adaptive Tetrahedral Tracing And Edge Diffraction Model, Carl R. Hart May 2014

On A Combined Adaptive Tetrahedral Tracing And Edge Diffraction Model, Carl R. Hart

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

A major challenge in architectural acoustics is the unification of diffraction models and geometric acoustics. For example, geometric acoustics is insufficient to quantify the scattering characteristics of acoustic diffusors. One method of quantifying the scattering characteristics of acoustic diffusers is through computational prediction, typically via the time-independent boundary element method (BEM). In contrast, time-domain computations are of interest for characterizing both the spatial and temporal scattering characteristics of acoustic diffusors. Hence, a method is sought that predicts acoustic scattering in the time-domain. A prediction method, which combines an advanced image source method and an edge diffraction model, is investigated for …


Method And System For Optimal Coordination Control And Soft Repair Of Multiple Rooftop Heating And Cooling Units, Haorong Li Jan 2014

Method And System For Optimal Coordination Control And Soft Repair Of Multiple Rooftop Heating And Cooling Units, Haorong Li

Durham School of Architectural Engineering and Construction: Faculty Publications

Techniques are described that may be implemented in an adaptive control device to regulate multiple zone environmental units based upon multiple temperature values and multiple airflow values, where each temperature value and each airflow value is related to the temperature and the airflow in a specific zone. In an implementation, the input interface of the adaptive control device is configured to receive multiple temperature values and multiple air flow values from multiple zone sensors. The adaptive control device may calculate multiple operational values based on the multiple temperature values and the multiple air flow values. An operational value indicates a …


The Influence Of National Culture On Effectiveness Of Safety Trainings During Postdisaster Reconstruction, Behzad Esmaeili, Kevin Grosskopf, Amy Javernick-Will Jan 2014

The Influence Of National Culture On Effectiveness Of Safety Trainings During Postdisaster Reconstruction, Behzad Esmaeili, Kevin Grosskopf, Amy Javernick-Will

Durham School of Architectural Engineering and Construction: Faculty Publications

Non-English speaking workers constitute a disproportionately high number of workers involved in postdisaster reconstruction. Additionally, the rate of fatality among these workers is higher than the industry average. Research shows this population is more prone to unsafe behaviors in the working environment, conceivably because many of these workers are sent into the field prior to any formalized training. Recent studies show that the native culture of construction workers can impact risk-taking behavior. While numerous researchers have attempted to develop training materials for Hispanic workers, the number of studies that consider the impact of native culture on safety behavior is minimal. …


Virtual Surface Temperature Sensor For Multi-Zone Commercial Buildings, Yuebin Yu, Denchai Woradechjumroen, Daihong Yu Jan 2014

Virtual Surface Temperature Sensor For Multi-Zone Commercial Buildings, Yuebin Yu, Denchai Woradechjumroen, Daihong Yu

Durham School of Architectural Engineering and Construction: Faculty Publications

Multi-zone structure is commonly used in small commercial office buildings, retail stores and supermarket. While there is no adjacent wall between the zones, the impact of a neighbor zone on the current zone can be approximated and analyzed through the application of virtual walls. It is critical to accurately estimate the virtual wall surface temperature in order to evaluate the model uncertainty and apply improved supervisory control on multiple rooftop air-conditioning units (RTUs). We propose an innovative virtual surface temperature sensor based on system-identification to solve this challenge. The validation of the virtual temperature model is processed by the three …


Shallow Flat Soffit Precast Concrete Floor System, George Morcous, Maher Tadros Jan 2014

Shallow Flat Soffit Precast Concrete Floor System, George Morcous, Maher Tadros

Durham School of Architectural Engineering and Construction: Faculty Publications

A precast concrete floor system that eliminates the need for column corbels and beam ledges while being very shallow. The main advantages of the present system include a span to-depth ratio of 30, a flat soffit, economy, consistency with prevailing erection techniques, and fire and corrosion protection. The present system consists of continuous precast columns, prestressed rectangular beams, hollow-core planks, and cast-in-place composite topping. Testing results have indicated that a 12 inch deep flat soffit precast floor system has adequate capacity to carry gravity loads (including 100 psf live load) in a 30 ft x 30 ft bay size. Testing …


Hybrid Of Natural Element Method (Nem) With Genetic Algorithm (Ga) To Find Critical Slip Surface, Shahriar Shahrokhabadi, Vahid Khoshfahm, Hamed Nabizadeh Rafsanjani Jan 2014

Hybrid Of Natural Element Method (Nem) With Genetic Algorithm (Ga) To Find Critical Slip Surface, Shahriar Shahrokhabadi, Vahid Khoshfahm, Hamed Nabizadeh Rafsanjani

Durham School of Architectural Engineering and Construction: Faculty Publications

One of the most important issues in geotechnical engineering is the slope stability analysis for determination of the factor of safety and the probable slip surface. Finite Element Method (FEM) is well suited for numerical study of advanced geotechnical problems. However, mesh requirements of FEM creates some difficulties for solution processing in certain problems. Recently, motivated by these limitations, several new Meshfree methods such as Natural Element Method (NEM) have been used to analyze engineering problems. This paper presents advantages of using NEM in 2D slope stability analysis and Genetic Algorithm (GA) optimization to determine the probable slip surface and …


Rating Low Levels Of Ambient Noise In Performing Arts Facilities, Lily M. Wang, Brent A. Kraay Jun 2013

Rating Low Levels Of Ambient Noise In Performing Arts Facilities, Lily M. Wang, Brent A. Kraay

Durham School of Architectural Engineering and Construction: Faculty Publications

Previous studies have indicated that common indoor noise rating metrics, such as Noise Criteria NC and Room Criteria RC, do not best correlate to human perceptions of annoyance and distraction in typical office environments. Based on investigations conducted at the University of Nebraska using noise levels between 30 – 60 dBA, the author has proposed that an effective indoor noise rating method should begin with a rating of level (either dBA or sones), then an assessment of spectral quality, tones, and fluctuations. How well would such a system work at very low levels of ambient noise, though, as found in …


Quantifying The Just Noticeable Difference Of Reverberation Time With Band-Limited Noise Centered Around 1000 Hz Using A Transformed Up-Down Adaptive Method, Matthew G. Blevins, Adam T. Buck, Zhao Peng, Lily M. Wang Jun 2013

Quantifying The Just Noticeable Difference Of Reverberation Time With Band-Limited Noise Centered Around 1000 Hz Using A Transformed Up-Down Adaptive Method, Matthew G. Blevins, Adam T. Buck, Zhao Peng, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

This study seeks to quantify the just noticeable difference (JND) of reverberation time (RT) using band-limited noise. ISO 3382-1 lists the JND of reverberation metrics at 5% based on work by Seraphim (1958). However, others have found the JND of RT to be higher from 6% to 39%. Many of these studies utilized band-limited stimuli, e.g. speech, music motifs and bandlimited noise. A previous study by the authors conducted on 30 subjects using white noise demonstrated a JND of RT at 22%. To further verify these results and investigate potential upward frequency masking, the present study was conducted following the …


Effects Of Background Noise Alternating Between Two Levels At Varying Time Intervals On Human Perception And Performance, Andrew Hathaway, Lily M. Wang Jun 2013

Effects Of Background Noise Alternating Between Two Levels At Varying Time Intervals On Human Perception And Performance, Andrew Hathaway, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

This research experiment aims to better quantify human perception and performance under increased background noise levels of varying intervals. Twenty-seven participants were tested over five 30 minute sessions where they were subjected to RC-29(H) and RC-47(RV) conditions created by broadband noise fluctuating on different time intervals. These intervals varied from two minutes to ten minutes, simulating the conditions of a noisy HVAC system turning on and off. The performance results of an arithmetic test dealing with short-term memory and a subjective questionnaire will be presented and compared to a similar test using broadband noise bursts and correlated to noise metrics …


Effects Of Reverberation And Noise On Speech Comprehension By Native And Non-Native English-Speaking Listeners, Zhao Peng, Lily M. Wang, Siu Kit Lau, Adam M. Steinbach Jun 2013

Effects Of Reverberation And Noise On Speech Comprehension By Native And Non-Native English-Speaking Listeners, Zhao Peng, Lily M. Wang, Siu Kit Lau, Adam M. Steinbach

Durham School of Architectural Engineering and Construction: Faculty Publications

Previous studies have demonstrated the negative impact of adverse signal-to-noise-ratios on non-native English-speaking listeners' performance on speech recognition using recall tasks, as well as implied that comprehension skills were more impaired than recognition skills under reverberation and noise. The authors have themselves previously conducted a pilot study on three native and three non-native Englishspeaking listeners to examine the effects of reverberation and noise using speech comprehension tasks. Those results suggested that speech comprehension performance is worse under longer reverberation times (RT), and that a longer RT is more detrimental to speech comprehension by non-native listeners than native listeners. This paper …


Pump Controller Design For Variable Primary Flow Configuration Systems, Yifan Shi May 2013

Pump Controller Design For Variable Primary Flow Configuration Systems, Yifan Shi

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

Pump systems are utilized widely in Heating, Ventilation and Air-Conditioning (HVAC) systems. There are mainly three configuration types: (1) the constant primary-only flow configuration, (2) the constant primary/variable secondary flow configuration, and (3) the variable primary-only flow configuration. This thesis focuses on finding the optimal control strategy for it and programming a controller for easy in-field usage.

In this thesis, the pump brake horse power (BHP) of the three pump configurations is simulated and compared using varying control methods. The best pump efficiency staging and DP reset control methods are implemented into the pump controller. A one month field experiment …


Precast Concrete Insulated Wall Panel Corbels Without Thermal Bridging, Mohamed Elkady Apr 2013

Precast Concrete Insulated Wall Panel Corbels Without Thermal Bridging, Mohamed Elkady

Department of Construction Engineering and Management: Dissertations, Theses, and Student Research

The common practice in corbel design is to block out the insulation in order to provide a solid concrete area at the corbel location. This connection practice results in thermal bridging, which significantly reduces the energy performance of the panel. For example, the PCI Design Handbook indicates that the reduction in thermal resistance caused by a solid part with an area equal to 9% of the total panel surface area is as high as 42%. This paper presents a discussion of a new concept for corbel design of insulated wall panels with the thermal break totally preserved. Two different designs …


Evaluation Of Statistical Energy Analysis For Prediction Of Breakout Noise From Air Duct, Himanshu S. Malushte Apr 2013

Evaluation Of Statistical Energy Analysis For Prediction Of Breakout Noise From Air Duct, Himanshu S. Malushte

Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research

The breakout noise from an air-conditioning duct is of immense concern in order to maintain a sound environment at home, office spaces, hospitals, etc. The challenge lies in correctly estimating the breakout noise by knowing the breakout sound transmission loss from the air duct. The ASHRAE Handbook: HVAC Applications (ASHRAE, 2011) currently lists some of theoretical transmission loss values for limited duct dimensions and gages (duct-wall thickness) at the octave band frequencies. Statistical Energy Analysis (SEA) is promising to predict the sound transmission loss for breakout noise for any given air duct configuration, particularly at high frequency. Though there are …


Multi-Objective Time-Cost Optimization Using Cobb-Douglas Production Function And Hybrid Genetic Algorithm, Zhigang Shen, Ashkan Hassani, Qian Shi Apr 2013

Multi-Objective Time-Cost Optimization Using Cobb-Douglas Production Function And Hybrid Genetic Algorithm, Zhigang Shen, Ashkan Hassani, Qian Shi

Durham School of Architectural Engineering and Construction: Faculty Publications

Existing research on construction time-cost tradeoff issues rarely explore the origin of the crashing cost. Crashing cost function was either assumed without much justification, or came from historical data of some real projects. As a result the conclusions of the papers can hardly be used to guide allocations of labor and equipment resources respectively. The authors believe Cobb-Douglas function provides a much-needed piece to modeling the cost functions in the construction time-cost tradeoff problem during the crashing process. We believe this new perspective fills a gap of existing time-cost tradeoff research by considering project duration, labor and equipment cost as …


Relationships Between Unoccupied Classroom Acoustical Conditions And Elementary Student Achievement Measured In Eastern Nebraska, Lauren M. Ronsse, Lily M. Wang Mar 2013

Relationships Between Unoccupied Classroom Acoustical Conditions And Elementary Student Achievement Measured In Eastern Nebraska, Lauren M. Ronsse, Lily M. Wang

Durham School of Architectural Engineering and Construction: Faculty Publications

Building standards recommend maximum background noise levels (BNL) and reverberation times (RT) for unoccupied classrooms. However, existing research does not show a consistent correlation between these parameters and student achievement. Through in situ testing, this research seeks to determine what acoustical conditions should be attained in elementary schools for students to meet educational goals. Acoustical measurements were conducted in a Nebraska public school system and correlated to achievement scores from students in the surveyed classrooms. Unoccupied BNLs and RTs were gathered in 34 third and 33 fifth-grade classrooms. Additionally, binaural room impulse response measurements were gathered in a subset of …