Open Access. Powered by Scholars. Published by Universities.®
- Discipline
-
- Engineering (198)
- Construction Engineering (151)
- Other Engineering (141)
- Environmental Design (140)
- Mechanical Engineering (31)
-
- Acoustics, Dynamics, and Controls (27)
- Civil and Environmental Engineering (19)
- Construction Engineering and Management (12)
- Electrical and Computer Engineering (8)
- Medicine and Health Sciences (7)
- Physical Sciences and Mathematics (7)
- Public Health (6)
- Social and Behavioral Sciences (6)
- Structural Engineering (6)
- Architectural Technology (5)
- Engineering Science and Materials (4)
- Environmental Sciences (4)
- Occupational Health and Industrial Hygiene (4)
- Civil Engineering (3)
- Education (3)
- Electrical and Electronics (3)
- Environmental Public Health (3)
- Mechanics of Materials (3)
- Power and Energy (3)
- Public Affairs, Public Policy and Public Administration (3)
- Sociology (3)
- Arts and Humanities (2)
- Computer Engineering (2)
- Keyword
-
- Noise (20)
- Room acoustics (15)
- Acoustics (11)
- Classroom acoustics (8)
- Human performance (8)
-
- Attic (6)
- Auralization (6)
- Human perception (6)
- Reverberation (6)
- Student achievement (6)
- Annoyance (5)
- Building mechanical systems (5)
- Indoor air quality (5)
- MEMS (5)
- Machine learning (5)
- Speech comprehension (5)
- Tones (5)
- HVAC (4)
- Lighting (4)
- Sustainability (4)
- Turbulence (4)
- Building energy modeling (3)
- CFD. (3)
- Circadian (3)
- Corrosion (3)
- Energy consumption (3)
- Load profile (3)
- Noise criteria (3)
- Non-Intrusive Load Monitoring (3)
- Reinforced concrete bridge decks (3)
- Publication Year
- Publication
-
- Durham School of Architectural Engineering and Construction: Faculty Publications (219)
- Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research (74)
- Dissertations and Doctoral Documents, University of Nebraska-Lincoln, 2023– (5)
- UCARE: Research Products (2)
- Architecture Program: Faculty Scholarly and Creative Activity (1)
-
- Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research (1)
- Department of Civil and Environmental Engineering: Faculty Publications (1)
- Department of Construction Engineering and Management: Dissertations, Theses, and Student Research (1)
- Department of Mathematics: Faculty Publications (1)
- Department of Mechanical and Materials Engineering: Faculty Publications (1)
- Professional and Organizational Development Network in Higher Education: POD Network News (1)
- UNL Faculty Course Portfolios (1)
Articles 121 - 150 of 308
Full-Text Articles in Architectural Engineering
Analyses Of Crowd-Sourced Sound Levels Of Restaurants And Bars In New York City, Gregory S. Farber, Lily M. Wang
Analyses Of Crowd-Sourced Sound Levels Of Restaurants And Bars In New York City, Gregory S. Farber, Lily M. Wang
Durham School of Architectural Engineering and Construction: Faculty Publications
For several decades, there has been a significant need to better educate the public about noise pollution. A small number of small-scale studies have focused on the sound levels of restaurants and their impact on health and hearing. There have also been an increasing number of media articles stating that eating and drinking venues are getting increasingly loud making it more difficult for people to connect with others in conversation. This study reports on an exploratory large-scale noise survey of sound levels of 2,376 restaurants and bars in New York City using a novel smart-phone application and categorized them based …
Numerical Simulation Of Fault Impacts For Commercial Walk-In Freezers, Alireza Behfar, David P. Yuill
Numerical Simulation Of Fault Impacts For Commercial Walk-In Freezers, Alireza Behfar, David P. Yuill
Durham School of Architectural Engineering and Construction: Faculty Publications
Refrigeration systems can undergo many faults that could negatively affect their operation and performance. This paper describes a modeling process to simulate the fault impacts on the operation of a commercial walk-in freezer using semi-empirical models. These models often require less modeling effort than full forward models and could be used in scenarios where detailed information is missing, such as in field-measured systems. An important characteristic of a typical walk-in refrigeration system is the existence of a liquid-line receiver after the condenser, which significantly changes the behavior of the cycle, in comparison to a receiver-less system. Component models described in …
Simultaneous Electrical And Mechanical Resonance Drive For Large Signal Amplification Of Micro Resonators, M. H. Hasan, Fadi M. Alsaleem, N. Jaber, M. A. A. Hafiz, M. I. Younis
Simultaneous Electrical And Mechanical Resonance Drive For Large Signal Amplification Of Micro Resonators, M. H. Hasan, Fadi M. Alsaleem, N. Jaber, M. A. A. Hafiz, M. I. Younis
Durham School of Architectural Engineering and Construction: Faculty Publications
Achieving large signal-noise ratio using low levels of excitation signal is key requirement for practical applications of micro and nano electromechanical resonators. In this work, we introduce the double electromechanical resonance drive concept to achieve an order-of-magnitude dynamic signal amplification in micro resonators. The concept relies on simultaneously activating the micro-resonator mechanical and electrical resonance frequencies. We report an input voltage amplification up to 15 times for a micro-resonator when its electrical resonance is tuned to match the mechanical resonance that leads to dynamic signal amplification in air (Quality factor enhancement). Furthermore, using a multi-frequency excitation technique, input voltage and …
Impact Of Owners’ Early Decisions On Project Performance And Dispute Occurrence In Public Highway Projects, Sogand Hasanzadeh, Behzad Esmaeili, Ghada M. Gad, Douglas D. Gransberg
Impact Of Owners’ Early Decisions On Project Performance And Dispute Occurrence In Public Highway Projects, Sogand Hasanzadeh, Behzad Esmaeili, Ghada M. Gad, Douglas D. Gransberg
Durham School of Architectural Engineering and Construction: Faculty Publications
Disputes are common in the construction industry and lead to unnecessary cost and schedule overruns in projects. It is commonly believed that owners’ early decisions regarding the selection of delivery methods, procurement methods, and contract types impact the frequency and severity of project disputes; however, no previous study has empirically tested this hypothesis, particularly in highway public projects. Therefore, this study empirically investigated the impact of owners’ early decisions regarding project organization (i.e., delivery methods, procurement, and contract types) on performance measures (e.g., cost and schedule growth), specifically dispute performance metrics (e.g., frequency and severity of disputes), in public highway …
Method For Radon Measurement In Residential Sewer Connections, David Yuill
Method For Radon Measurement In Residential Sewer Connections, David Yuill
Durham School of Architectural Engineering and Construction: Faculty Publications
Radon gas is the most deadly indoor air pollutant. In the US, it is responsible for over 20,000 deaths per year. Residential exposure is typically the largest portion of a person’s annual exposure, so a great deal of research has been done to understand the pathways that radon can follow to enter a house. Since radon emanates from the ground, it is present in high concentration in soil gas. Recent research on the vapor intrusion of volatile organic compounds from subsurface sources into a test house concluded that the sewer line is an important preferential pathway. Despite the potential for …
Utilizing Wearable Devices To Design Personal Thermal Comfort Model, Mostafa Rafaie, Mehari Tesfay, Fadi Alsaleem
Utilizing Wearable Devices To Design Personal Thermal Comfort Model, Mostafa Rafaie, Mehari Tesfay, Fadi Alsaleem
Durham School of Architectural Engineering and Construction: Faculty Publications
have confirmed that thermal comfort significantly depends on internal personal parameters such as metabolic rate, age, and health status. This is manifested as a difference in comfort levels between people residing under the same roof, and hence no general comprehensive comfort model satisfying everyone. Current and newly emerging advancements in state of the art wearable technology have made it possible to continuously acquired biometric information. This work proposes to access and exploit this data to build personal thermal comfort model. Relying on various supervised machine-learning methods, a personal thermal comfort model will be produced and compared to a general model …
Localized Indoor Temperature Estimation Using Smartphone And Laptop Internal Sensors, Mostafa Rafaie, Mehari Tesfay, Fadi Alsaleem
Localized Indoor Temperature Estimation Using Smartphone And Laptop Internal Sensors, Mostafa Rafaie, Mehari Tesfay, Fadi Alsaleem
Durham School of Architectural Engineering and Construction: Faculty Publications
This paper investigates a mechanism in which indoor air temperature can be predicted using the temperature sensor on the battery and the CPU of smartphones or laptops, where data is easily accessible and ubiquitous. As a case study, several machine-learning methods were used to build models from a laptop data and the measured surrounding air temperature. The effects of the machine learning type and input feature size (by including other parameters such as CPU processing usage and battery charge percentage) on the model accuracy were investigated. The goal is to determine a set of feature combinations that can be used …
Comfort-Based Optimal Temperature Setpoint Calculation, Andrew Holthaus, Mostafa Rafaie, Fadi Alsaleem
Comfort-Based Optimal Temperature Setpoint Calculation, Andrew Holthaus, Mostafa Rafaie, Fadi Alsaleem
Durham School of Architectural Engineering and Construction: Faculty Publications
General practice in current building HVAC control is to select building temperature setpoints that comply with ASHRAE Standard 55. By meeting this standard, based on the PMV comfort model, 80% of building occupants should be satisfied with their thermal environment. However, unfortunately, this is rarely the case. One possible reason for this is the variation in occupant activity and clothing that are usually assumed default values using this standard. In this work, we present an iterative-based algorithm to solve this problem. The algorithm solves the PMV inverse model equation to determine the optimal temperature setpoint while inferring human activity level …
Sdnet2018: An Annotated Image Data Set For Non-Contact Concrete Crack Detection Using Deep Convolutional Neural Networks, Sattar Dorafshan, Robert J. Thomas, Marc Maguire
Sdnet2018: An Annotated Image Data Set For Non-Contact Concrete Crack Detection Using Deep Convolutional Neural Networks, Sattar Dorafshan, Robert J. Thomas, Marc Maguire
Durham School of Architectural Engineering and Construction: Faculty Publications
SDNET2018 is an annotated image data set for training, validation, and benchmarking of artificial intelligence based crack detection algorithms for concrete. SDNET2018 contains over 56,000 images of cracked and non-cracked concrete bridge decks, walls, and pavements. The dataset includes cracks as narrow as 0.06 mm and as wide as 25 mm. The data set also includes images with a variety of obstructions, including shadows, surface roughness, scaling, edges, holes, and background debris. SDNET2018 will be useful for the continued development of concrete crack detection algorithms based on deep convolutional neural networks (DCNNs), which are a subject of continued research in …
Evaluation The Effect Of Washing On The Heat Transfer Capacity And Air-Side Flow Resistance Of Air Cooled Condensers, Mehdi Mehrabi, David Yuill
Evaluation The Effect Of Washing On The Heat Transfer Capacity And Air-Side Flow Resistance Of Air Cooled Condensers, Mehdi Mehrabi, David Yuill
Durham School of Architectural Engineering and Construction: Faculty Publications
17th International Refrigeration and Air Conditioning Conference at Purdue, July 9-12, 2018
Infrared Thermography For Weld Inspection: Feasibility And Application, Sattar Dorafshan, Marc Maguire, William Collins
Infrared Thermography For Weld Inspection: Feasibility And Application, Sattar Dorafshan, Marc Maguire, William Collins
Durham School of Architectural Engineering and Construction: Faculty Publications
Traditional ultrasonic testing (UT) techniques have been widely used to detect surface and sub-surface defects of welds. UT inspection is a contact method which burdens the manufacturer by storing hot specimens for inspection when the material is cool. Additionally, UT is only valid for 5 mm specimens or thicker and requires a highly skilled operator to perform the inspections and interpret the signals. Infrared thermography (IRT) has the potential to be implemented for weld inspections due to its non-contact nature. In this study, the feasibility of using IRT to overcome the limitations of UT inspection is investigated to detect inclusion, …
Hvac System Remote Monitoring And Diagnosis Of Refrigerant Line Obstruction, Fadi M. Alsaleem
Hvac System Remote Monitoring And Diagnosis Of Refrigerant Line Obstruction, Fadi M. Alsaleem
Durham School of Architectural Engineering and Construction: Faculty Publications
A heating, ventilation, and air conditioning (HVAC) system of a building includes a refrigerant loop. A monitoring system for the HVAC system includes a monitoring device installed at the building. The monitoring device is configured to measure a first temperature of refrigerant in a refrigerant line located between a filter - drier of the refrigerant loop and an expansion valve of the refrigerant loop. The monitoring system includes a monitoring server, located remotely from the building. The monitoring server is con figured to receive the first temperature and, in response to the first temperature being less than a threshold, generate …
Harmonics Elimination In Three Phase Cascade H-Bridge Multilevel Inverter Using Virtual Stage Pwm, Amro Quedan
Harmonics Elimination In Three Phase Cascade H-Bridge Multilevel Inverter Using Virtual Stage Pwm, Amro Quedan
Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research
The multilevel inverters are one of the great solutions that are proposed to satisfy the demand for high-power application and the significant integration of renewable energy. The conversion process from DC to AC must be done at high efficiency to decrease the energy loss and to ensure the electric grid power quality. The Total Harmonic Distortion (THD) is the most important feature that indicates the efficiency of the conversion process. In this research, due to the advantages of the cascade H-bridge inverter over other topologies, it has been used with the virtual stage PWM technique to investigate two different methods …
Perception Of Spatial Impression Due To Varying Positions Of The Source On Stage, Sungbeen Cho
Perception Of Spatial Impression Due To Varying Positions Of The Source On Stage, Sungbeen Cho
Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research
The listener’s surrounding environment affects the perception of sound. The environment includes physical factors such as space size, shape, and finish materials, and psychological factors such as individual difference of impression, and vision. Acoustic spatial impression can be defined as the concept of the type and size of space at which a listener arrives spontaneously when he/she is exposed to an appropriate sound field. This thesis analyzes how physical factors in enclosed spaces affect the acoustic spatial impression, and how sound sources at different positions on stage are perceived in different shapes of spaces.
First, existing spatial impression parameters, IACC …
Hyperelastic Structural Fuses For Improved Earthquake Resilience Of Steel Concentrically-Braced Buildings, Francys López-Mosquera
Hyperelastic Structural Fuses For Improved Earthquake Resilience Of Steel Concentrically-Braced Buildings, Francys López-Mosquera
Department of Civil and Environmental Engineering: Dissertations, Theses, and Student Research
Improving structural resilience (i.e., reducing service interruptions and improving rapidity of function restoration) following extreme events is one of the primary contemporary challenges in structural engineering. While massive casualties have successfully been avoided through the adoption of modern building codes, the sole codified performance objective has been limited to the life safety/collapse prevention range of response. Christchurch, NZ, highlighted the insufficiency of this approach, with large sections of the city nonfunctional after a major earthquake, and with subsequent collapses induced by significant aftershocks. Engineering advances to improve building and community resilience are necessary to mitigate hazards from becoming disasters. This …
Gas Collection, Haorong Li, Yanshun Yu, Daihong Yu
Gas Collection, Haorong Li, Yanshun Yu, Daihong Yu
Durham School of Architectural Engineering and Construction: Faculty Publications
A system includes a vessel configured to couple with a gas source for drawing gas into the vessel. The vessel is also configured to receive liquid. The system includes an over flow port in fluid communication with the environment external to the vessel. The overflow port is configured to separate gas within the vessel from the external environment. The system also includes an overflow conduit having an end within the overflow port so that when gas pressure within the vessel increases, liquid is received by the over flow conduit. Another system includes a tank defining an air space for receiving …
Design And Simulation A Novel Three-Phase, Five-Level Inverter Topology, Fares Al Juheshi
Design And Simulation A Novel Three-Phase, Five-Level Inverter Topology, Fares Al Juheshi
Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research
There is a high integration of renewable energy sources in modern building electrical systems. The main components of these new systems are power electronics switches that inherit their foundations from signal amplifier technologies and then developed to drive high powers. Nowadays, the static converter can connect systems with different electrical characteristics. For instance, choppers connect two DC systems with different voltage levels, whereas inverters transform power from DC to AC with variable amplitude and frequency. Since multilevel inverters offer a better quality of the output waveforms than standard inverters, a novel three-phase, five-level inverter topology is proposed. The goal of …
Exploring The Correlation Between Occupied And Unoccupied Noise Levels In K–12 Classrooms, Laura Caroline Brill
Exploring The Correlation Between Occupied And Unoccupied Noise Levels In K–12 Classrooms, Laura Caroline Brill
Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research
Students learn in occupied spaces, yet acoustical standards specify recommendations for unoccupied levels. While some studies have quantified the relationship between occupied and background noise levels in classrooms, their definitions of background noise level were often inconsistent with those recommended by the standards. The research presented in this thesis examines the relationship between occupied and unoccupied levels in 110 classrooms in two Midwestern school districts. Acoustic levels were logged for a total of six days in each classroom. Occupied and unoccupied levels were parsed from the logged data using k-means clustering, an unsupervised statistical learning technique. The results from this …
How Tonality And Loudness Of Noise Relate To Annoyance And Task Performance” Noise Control Eng. J. 65(2), 71-82., Joonhee Lee, Jennifer M. Francis, Lily M. Wang
How Tonality And Loudness Of Noise Relate To Annoyance And Task Performance” Noise Control Eng. J. 65(2), 71-82., Joonhee Lee, Jennifer M. Francis, Lily M. Wang
Durham School of Architectural Engineering and Construction: Faculty Publications
Audible tones in noise generated by building mechanical equipment can be a leading cause of complaints from occupants. A number of metrics have been developed to quantify prominence of a tone, but previous work has shown that the impact of a certain tonality appears to vary with the level of the broadband noise signal. More work on how tonal signals of varying tonality, tone frequency and broadband noise levels relate to annoyance and task performance is needed. This paper investigates such relationships between current noise metrics, annoyance and task performance under assorted tonal noise conditions through subjective testing. Participants rated …
Research On Control Methods Of Roof Radiant Cooling System, Yongbin Li, Zhaoyi Zhuang, Qiqi Zhu, Jian Song, Haipeng An
Research On Control Methods Of Roof Radiant Cooling System, Yongbin Li, Zhaoyi Zhuang, Qiqi Zhu, Jian Song, Haipeng An
Durham School of Architectural Engineering and Construction: Faculty Publications
Taking the capillary ceiling radiation air conditioning system in radiation cooling Laboratory of comprehensive experimental building in Shandong Jianzhu University as an example, research the two different control methods which are room temperature control and water temperature control. The roof cooling model was established by using TRNSYS simulation software, two typical summer days were selected to explore the stability of the room temperature and the supply and return water temperature, research the comfort of human body and system energy consumption under two control methods. The results show that the indoor temperature of the two control methods can be stable at …
Gas Generation, Haorong Li, Daihong Yu, Yanshun Yu
Gas Generation, Haorong Li, Daihong Yu, Yanshun Yu
Durham School of Architectural Engineering and Construction: Faculty Publications
A first system includes a feedstock load port and a feedstock discharge port. The first system also includes a tank configured to retain biomass feedstock for aerobic biodegradation. The first system further includes a mechanical ventilator in fluid communication with the tank. The mechanical ventilator is configured to supply air to facilitate the aerobic biodegradation of the biomass feedstock. The first system also includes an exhaust port configured to receive gas generated during the aerobic biodegradation. A second system includes a feedstock load port and a feedstock discharge port. The second system also includes a pressure vessel configured to retain …
Study On The Methods For Predicting The Performance Of A Hybrid Solar-Assisted Ground-Source Heat Pump System, Zhaoyi Zhuang, Qiqi Zhu, Jian Song, Xin Zhang, Haorong Li
Study On The Methods For Predicting The Performance Of A Hybrid Solar-Assisted Ground-Source Heat Pump System, Zhaoyi Zhuang, Qiqi Zhu, Jian Song, Xin Zhang, Haorong Li
Durham School of Architectural Engineering and Construction: Faculty Publications
It is critical to find suitable setting parameters for designing a hybrid solar-assisted ground-source heat pump system in the practical engineering application, but the heat pump performance is unpredictable after many years of operation. This paper used 2000 sets of performance data collected from solar-assisted GSHP systems that keep operating over 20 years to simulate long term used heat pump with a professional software called GeoStar. Adopted the classification and regression tree (CART) method, the design of solar energy collector areas can be predicted. The multi-linear regression is also utilized to predict average monthly per meter borehole heat exchange. Seasonal …
Research On The Cooling Characteristics In Building Interior Zones Using Displacement Ventilation System, Zhaoyi Zhuang, Yongbin Li, Qiqi Zhu, Jian Song, Haipeng An, Haorong Li
Research On The Cooling Characteristics In Building Interior Zones Using Displacement Ventilation System, Zhaoyi Zhuang, Yongbin Li, Qiqi Zhu, Jian Song, Haipeng An, Haorong Li
Durham School of Architectural Engineering and Construction: Faculty Publications
The outdoor low temperature fresh air can be used as a free cold source to eliminate waste heat for the building interior zones during the transition season and winter. This paper takes a project in Hunan as an example, and the project building interior zones is 25m×7m×3.9m(L×W×H). Using Fluent software to simulate the temperature field and velocity field both the interior and exterior zones of the engineering offices. The simulation results show that using the displacement ventilation system to take the outdoor air into inner rooms not only cooling but also improving the air quality and adding comfort. According to …
Performance And Energy Efficiency Analysis Of Data Center Cooling Plant By Using Lake Water Source, Li Ling, Quan Zhang, Liping Zeng
Performance And Energy Efficiency Analysis Of Data Center Cooling Plant By Using Lake Water Source, Li Ling, Quan Zhang, Liping Zeng
Durham School of Architectural Engineering and Construction: Faculty Publications
A cooling plant by using lake water source was proposed to cool the space in data centers. It combines free cooling technology and variable capacity technology to remove heat and reduce energy consumption effectively. In this paper, firstly, the control strategies for this cooling plant were proposed. Then, a detailed annual energy consumption model with considering the effect of the dynamic heat dissipation characteristics of servers, lake water temperature, outdoor weather conditions, and cooling plant thermal performance, will be established to evaluate the performance and energy efficiency of this cooling plant under different load factors. The results show the mode …
Hvac System Remote Monitoring And Diagnosis, Jeffrey N. Arensmeier, Gregg M. Hemmelgarn, Fadi M. Alsaleem, Priotomo Abiprojo
Hvac System Remote Monitoring And Diagnosis, Jeffrey N. Arensmeier, Gregg M. Hemmelgarn, Fadi M. Alsaleem, Priotomo Abiprojo
Durham School of Architectural Engineering and Construction: Faculty Publications
A monitoring system for a heating, ventilation, and air conditioning (HVAC) system of a building includes a monitoring device installed at the building, a monitoring server located remotely from the building, and a review server. The monitoring device measures an aggregate current Supplied to components of the HVAC system and transmits current data based on the measured aggregate current. The monitoring server receives the transmitted current data and, based on the received current data, assesses whether failures have occurred in first and second components of the HVAC components. The monitoring server generates a first advisory in response to determining that …
Project Impact: A Case Study Of Developing A Manufactured Construction Workforce Through Contextualized Training, Arefeh Mohammadi, Kevin R. Grosskopf
Project Impact: A Case Study Of Developing A Manufactured Construction Workforce Through Contextualized Training, Arefeh Mohammadi, Kevin R. Grosskopf
Durham School of Architectural Engineering and Construction: Faculty Publications
With a looming shortage of skilled craft workers forecast to exceed 2 million by 2017, prefabrication may become a necessity for many U.S. contractors attempting to remain competitive with a smaller, lower-skilled workforce. Building components manufactured in a controlled, offsite environment have proven to reduce time, cost and site logistics while improving productivity, quality, safety and sustainability. However, entry-level workers, including more than 765,000 recession displaced manufacturing workers, often lack the basic skills necessary to retrain for jobs in manufactured construction. As a result, a $ 6.3M U.S. Department of Labor grant was awarded to an institutional consortium to develop …
A Case Study Of Upper-Room Uvgi In Densely-Occupied Elementary Classrooms By Real-Time Fluorescent Bioaerosol Measurements, Chunxiao Su, Josephine Lau, Fang Yu
A Case Study Of Upper-Room Uvgi In Densely-Occupied Elementary Classrooms By Real-Time Fluorescent Bioaerosol Measurements, Chunxiao Su, Josephine Lau, Fang Yu
Durham School of Architectural Engineering and Construction: Faculty Publications
Recently, the requirement to continuously collect bioaerosol samples using shorter response times has called for the use of real-time detection. The decreased cost of this technology makes it available for a wider application than military use, and makes it accessible to pharmaceutical and academic research. In this case study, real-time bioaerosol monitors (RBMs) were applied in elementary school classrooms—a densely occupied environment—along with upper-room ultraviolet germicidal irradiation (UVGI) devices. The classrooms were separated into a UVGI group and a non-UVGI control group. Fluorescent bioaerosol counts (FBCs) were monitored on 20 visiting days over a four-month period. The classroom with upper-room …
Social Sustainability Indicators In Mass Housing Construction, Ali Karji, Asregedew Woldesenbet, Mostafa Khanzadi
Social Sustainability Indicators In Mass Housing Construction, Ali Karji, Asregedew Woldesenbet, Mostafa Khanzadi
Durham School of Architectural Engineering and Construction: Faculty Publications
In the construction industry, buildings constitute more than half of the new construction built in the world. With the rapid growth of population in urban areas and high-energy consumption of buildings, considerable attention and efforts have been devoted to creating a sustainably built environment. As a result, various sustainable rating systems, principles and tools have been developed in recent years. This paper presents efforts underway for evaluation of sustainability in mass housing construction projects in the Middle East from a social aspect. The study reviews reports, guidelines and best practices at national and international levels to detect key sustainability indicators. …
Heat - Pump System With Refrigerant Charge Diagnostics, Fadi M. Alsaleem, Gregg H. Hemmelgarn
Heat - Pump System With Refrigerant Charge Diagnostics, Fadi M. Alsaleem, Gregg H. Hemmelgarn
Durham School of Architectural Engineering and Construction: Faculty Publications
A heat-pump circuit may include an indoor heat exchanger, an outdoor heat exchanger, a compressor adapted to circulate a working fluid between the indoor and outdoor heat exchangers, and an expansion device disposed between the indoor and outdoor heat exchangers. A monitor for the heat-pump system may include a return-air temperature sensor, a supply-air temperature sensor, and a processor. The return-air temperature sensor may be adapted to measure a first air temperature of air upstream of the indoor heat exchanger. The supply-air temperature sensor may be adapted to measure a second air temperature of air down stream of the indoor …
An Investigation Of Dx Cooling Coil Inherent Characteristics, Krittima Santiwattana
An Investigation Of Dx Cooling Coil Inherent Characteristics, Krittima Santiwattana
Durham School of Architectural Engineering and Construction: Dissertations, Theses, and Student Research
DX cooling coil (DCC) systems have dominated light commercial and household applications in the U.S for several decades. Approximately 14.5% of energy use is consumed by space cooling in commercial buildings, whereas 87% of households are installed with air-conditioners. Improper installation, poor design, and lack of optimized control/operations incur faults in HVAC systems causing 25% to 50% energy waste in a building. These consequences are subject to inefficient equipment modelling of which is developed from: (1) insufficient understanding in equipment characteristics, (2) uncertainties in testing environment and data, and (3) access and cost limitations. Therefore, in this thesis DCC inherent …