Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

Utah State University

Discipline
Keyword
Publication Year
Publication
Publication Type

Articles 511 - 540 of 745

Full-Text Articles in Entire DC Network

An Approach To Solid Phase Identification In A Ca-S-O System By Quantitative Energy Dispersive X-Ray Microanalysis, K. Wieczorek-Ciurowa, S. J. Sivonen, P. Kokkonen Jul 1992

An Approach To Solid Phase Identification In A Ca-S-O System By Quantitative Energy Dispersive X-Ray Microanalysis, K. Wieczorek-Ciurowa, S. J. Sivonen, P. Kokkonen

Scanning Microscopy

Solid phases formed in the limestone sulphation reaction were identified by scanning electron microscopy with backscattered electron (BSE) imaging and by quantitative energy dispersive X-ray (EDX) microanalysis of calcium and sulphur. Since calcium and sulphur can form several compounds in the Ca-S-O system, two quantities, the sum of oxides (CaO+SO3) and the molar ratio (CaO/SO3), were used to calculate empirical formulae for the compounds actually present.

A method for analysing the experimental results is proposed, the mathematical expressions employed are presented and the numerical coefficients tabulated. It is shown with some examples that the method used …


Enamel Structure In Astrapotheres And Its Functional Implications, John M. Rensberger, Hans Ulrich Pfretzschner Jun 1992

Enamel Structure In Astrapotheres And Its Functional Implications, John M. Rensberger, Hans Ulrich Pfretzschner

Scanning Microscopy

Astrapotheres, large extinct ungulates of South America, share with rhinoceroses vertical prism decussation in the cheek tooth enamel. The similarity extends beyond merely the direction of the planes of decussation. The vertical decussation in astrapotheres is confined to the inner part of the enamel and has uniformly well-defined zones in which the prism direction differs by nearly 90° and the zones are separated by narrow transitional borders of intermediate prism direction. The outer enamel consists of predominantly occlusally and outwardly directed prisms. Within the outer enamel is a region of horizontally decussating prisms; here the angle of decussation is usually …


Scanning Electron Microscopic Studies Of The Oral Mucosa And Its Microvasculature: A Review Of The Palatine Mucosa And Its Microvascular Architecture In Mammals, Y. Ohta, S. Okada, I. Toda, H. Ike May 1992

Scanning Electron Microscopic Studies Of The Oral Mucosa And Its Microvasculature: A Review Of The Palatine Mucosa And Its Microvascular Architecture In Mammals, Y. Ohta, S. Okada, I. Toda, H. Ike

Scanning Microscopy

The present paper deals with the microvascular architecture of the palatine mucosa in primates, camivorae, and rodentia utilizing microvascular corrosion castings and epithelium-separated specimens.

The submucous vascular network is under-developed since the bard palatine mucosa was designated the mucoperiosteum, except some areas. The palatine venous plexus appears to show regional differences with animal species differences. The well-developed plexus is observed to be two-layered and may contribute to the process of regurgitation of rough food and assist in mastication with the palatine plicae. Formation and patterns of the arterial network in the lamina propria are in a close relation with connective …


Relationship Between Villous Shape And Mural Structure In Neutron Irradiated Small Intestine, K. E. Carr, J. S. Mccullough, A. C. Nelson, S. P. Hume, S. Nunn, H. H. M. Kamel Apr 1992

Relationship Between Villous Shape And Mural Structure In Neutron Irradiated Small Intestine, K. E. Carr, J. S. Mccullough, A. C. Nelson, S. P. Hume, S. Nunn, H. H. M. Kamel

Scanning Microscopy

Previous work on irradiation of mouse small intestine has assessed the changes produced by counting crypts/microcolonies, scoring villous shape or examining morphological changes in specific parts of the wall.

This paper used scanning and transmission electron microscopy to study the effects of whole body irradiation with 5 Gy neutrons on the surface and internal features of the intestinal wall of CFLP mice, 1 day, 3 days and 7 days after treatment.

Empirical scores from the ultrastructural findings were inserted into a Morphological Index display calculated from analytical data based on cell counts and area measurements obtained from resin histology sections. …


An Improved Method For Preparing Microvascular Corrosion Casts Of Rat Embryos, S. Yoshida, J. Chiba Apr 1992

An Improved Method For Preparing Microvascular Corrosion Casts Of Rat Embryos, S. Yoshida, J. Chiba

Scanning Microscopy

This paper presents an improved method for preparing microvascular corrosion casts of rat embryos (day 16.5-21.5). Special attention was paid on the viscosity of the casting material, the method of mechanical restraint, and the subsequent drying of the casts. The embryos were perfused with Mercox resin diluted with 25% methyl methacrylate monomer followed by undiluted Mercox resin to avoid outflow of resin from the vasculature after perfusion. The specimens were mounted on a stainless steel plate with self-curing resin to prevent flotation, mechanical damage, and collapse of the cast specimens following preparation. After digestion and washing, the cast specimens were …


The Scanning Probe Microscope, J. Jahanmir, B. G. Haggar, J. B. Hayes Apr 1992

The Scanning Probe Microscope, J. Jahanmir, B. G. Haggar, J. B. Hayes

Scanning Microscopy

Scanning probe microscopy bas evolved into a powerful tool since its inception in 1982. The scanning probe microscope bas found applications in metrology, spectroscopy, and lithography. We will review the background of the technology, discuss the different types of scanning probe microscopes including the scanning tunneling microscope and the scanning force microscope, and present many of the applications for the instrument.


The Interpretation Of X-Ray And Electron Signals Generated In Thin Or Layered Targets, R. H. Packwood, G. Remond Mar 1992

The Interpretation Of X-Ray And Electron Signals Generated In Thin Or Layered Targets, R. H. Packwood, G. Remond

Scanning Microscopy

This work outlines the development of a comprehensive theory for the electron probe microanalyser and scanning electron microscope or SEM, that is intended to serve as a framework of understanding for those employing electron beam methods and as a basis for improved correction procedures. There is particular emphasis on applications to layered and non-uniform specimens. Starting from a simple Gaussian depth distribution of electrons and making assumptions about the X-ray production, a series of predictions of X-ray and electron signals are made for various target configurations. When compared with experimental measurements a series of interesting discoveries follow, which, taken altogether, …


Microstructural Changes In Retrieved Amalgam Restorations, Grayson W. Marshall Jr., D. D. Mccoy, John H. Kinney, Hugo Letzel, Sally J. Marshall Jan 1992

Microstructural Changes In Retrieved Amalgam Restorations, Grayson W. Marshall Jr., D. D. Mccoy, John H. Kinney, Hugo Letzel, Sally J. Marshall

Cells and Materials

Many blended or dispersed phase high Cu amalgams show excellent clinical performance in long term clinical trials. However, little is known concerning the microstructural changes that occur during clinical use of these systems. This investigation sought to characterize some of the changes that occur in the Ag-Cu particles and their surrounding reaction zones based on a study by backscattered scanning electron microscopy (BSEM), energy dispersive spectroscopy and a new rnicroprobe technique called Colorad which assigns various colors to elements and element combinations and indicates changes in elemental concentration by changes in color value (brightness). Restorations were retrieved from clinical trials …


Reactogenicity Of Biomaterials As Studied By Biochemical, Morphological And Ultrastructural Techniques, Leonid I. Slutskii, Natalya A. Sevastjanova, Ivetta L. Ozolanta, Irina V. Kuzmina, Laimdota E. Dombrovska Jan 1992

Reactogenicity Of Biomaterials As Studied By Biochemical, Morphological And Ultrastructural Techniques, Leonid I. Slutskii, Natalya A. Sevastjanova, Ivetta L. Ozolanta, Irina V. Kuzmina, Laimdota E. Dombrovska

Cells and Materials

Reactogenicity is a characteristic of biocompatible materials that provokes the reparative and proliferative reaction of connective tissues, a compulsory stage of which is inflammation. Thus, reactogenicity studies should include experiments in vivo. A quantitative assessment of reactogenicity can be obtained by subcutaneous implantation of standard olive-shaped specimens covered by the biomaterial under study followed by biochemical, histological and scanning electron microscopical studies of the capsule developing around the implant. Reactogenicity of surgical threads is evaluated by semiquantitative histological analysis of the wound healing process after suture application. Biomaterial reactogenicity can be modified by changing the structure of the surface and …


Review: Biomaterials For Abdominal Wall Reconstruction, Roger K. J. Simmermacher, Robert P. Bleichrodt, Jeff M. Schakenraad Jan 1992

Review: Biomaterials For Abdominal Wall Reconstruction, Roger K. J. Simmermacher, Robert P. Bleichrodt, Jeff M. Schakenraad

Cells and Materials

The reconstruction of large abdominal wall defects still is a major surgical problem. Many different techniques have been developed for this purpose, most of which appeared to be unsatisfactory. The lack of sufficient tissue requires the insertion of prosthetic material. Non-absorbable prostheses used to reconstruct abdominal wall defects showed the best results . Polypropylene mesh (PPM) and expanded polytetrafluoroethylene (ePTFE) soft-tissue patch are the most frequently used materials for this purpose . However, PPM induces extensive visceral adhesions and erosion of the skin, whereas ePTFE is insufficiently anchored to the adjacent tissue and therefore both materials are not ideal. As …


The Microvasculature Of Human Oral Mucosa Using Vascular Corrosion Casts And India Ink Injection I. Tongue Papillae, Q. X. Yu, W. Ran, K. M. Pang, H. P. Philipsen, J. Theilade, X. H. Chen, Y. C. Mok Dec 1991

The Microvasculature Of Human Oral Mucosa Using Vascular Corrosion Casts And India Ink Injection I. Tongue Papillae, Q. X. Yu, W. Ran, K. M. Pang, H. P. Philipsen, J. Theilade, X. H. Chen, Y. C. Mok

Scanning Microscopy

The microvasculature of human tongue papillae originating from 9 males and 6 females, aged 0.5 to 2 years was studied by scanning electron microscopy (SEM) of vascular corrosion casts and by light microscopy (LM) of India ink injected specimens. All papillae showed a microvasculature characterized by primary, secondary and tertiary capillary loops. In the filiform papillae the loops were generally arranged in a corolla-like pattern with the tertiary loops demonstrating a hair-pin shape. The fungiform papillae showed basically a similar architectural pattern although the loops were somewhat more compact and complex in structure. A small, shallow depression of the tertiary …


Microscopy Of Mixed Surfaces On Layered Semiconductors, L. Margulis, D. Mahalu, B. Parkinson, R. Tenne Oct 1991

Microscopy Of Mixed Surfaces On Layered Semiconductors, L. Margulis, D. Mahalu, B. Parkinson, R. Tenne

Scanning Microscopy

A large number of well-defined hexagonal etch pits is produced on the WSe2 surface by controlled anisotropic corrosion. As a result a mixed surface (combining both ⊥c and ||c components) is created. This surface exhibits photovoltaic properties even better than the atomically smooth van der Waals surface. Measurements of electron beam induced current performed at low temperatures give direct evidence for enhanced current collection of ||c facets. Observations made by transmission electron microscopy and scanning tunneling microscopy show the presence of very low ||c steps on the van der Waals surface.


The Development Of The Vascular System In Quail Embryos: A Combination Of Microvascular Corrosion Casts And Immunohistochemical Identification, M. C. Deruiter, B. Hogers, R. E. Poelmann, L. Vanlperen, A. C. Gittenberger-De Groot Oct 1991

The Development Of The Vascular System In Quail Embryos: A Combination Of Microvascular Corrosion Casts And Immunohistochemical Identification, M. C. Deruiter, B. Hogers, R. E. Poelmann, L. Vanlperen, A. C. Gittenberger-De Groot

Scanning Microscopy

Although vascular casts, obtained by injection with methacrylates, are frequently used to investigate the adult vascular system, little data are available for embryonic stages. In this paper we use MercoxR in quail embryos in the period of 2 to 7 days after incubation. The microvascular corrosion casts were evaluated in the scanning electron microscope (SEM) with special attention to the development and remodelling of the large arteries and veins. Our results show that the remodelling of the large arteries and veins together with their developing tributary vessels can be visualized from very early embryonic stages onwards. However, complete replication …


Microvascularization Of The Pleura In Rats And Guinea Pigs, S. Aharinejad, A. Lametschwandtner, P. Böck, P. Franz Oct 1991

Microvascularization Of The Pleura In Rats And Guinea Pigs, S. Aharinejad, A. Lametschwandtner, P. Böck, P. Franz

Scanning Microscopy

The microvascularization of the visceral and parietal pleura was studied in rats and guinea pigs using vascular corrosion casts and scanning electron microscopy.

The visceral pleura was shown to be devoid of a vascular bed of its own. The capillary meshwork observed on the surface of the lung belongs to the pulmonary parenchyma. The parietal pleura, by contrast, possesses its own capillary network with an appropriate arterial supply and a venous drainage. The parietal pleural capillaries cover the costal regions completely, whereas the intercostal spaces are only provided by interspersed small patches of capillaries. That the feeding arteries of the …


Sphincters In The Rat Pulmonary Veins. Comparison Of Scanning Electron And Transmission Electron Microscopic Studies, S. Aharinejad, P. Böck, A. Lametschwandtner, P. Franz, W. Firbas Oct 1991

Sphincters In The Rat Pulmonary Veins. Comparison Of Scanning Electron And Transmission Electron Microscopic Studies, S. Aharinejad, P. Böck, A. Lametschwandtner, P. Franz, W. Firbas

Scanning Microscopy

The microvasculature of the rat lung was studied by scanning electron microscopy (SEM) and transmission electron microscopy (TEM) of vascular corrosion casts and tissue sections. Particular emphasis was placed on postcapillary venules, pulmonary venules and small pulmonary veins (small interlobular veins).

Casts of lung capillaries appeared inconspicuous with smooth surface. On the casts of pulmonary venules and small pulmonary veins, by contrast, series of narrow annular constrictions, present at regular distances of 20-25 μm, were seen. These constrictions may be drastic, narrowing down the caliber of the vessel up to 50%. In the constrictions the marks of circularly running tubular …


Scanning Electron Microscopy To Establish The Marble Weathering Mechanism In The Alhambra Of Granada (Spain), M. A. Bello, L. Martín, A. Martín Sep 1991

Scanning Electron Microscopy To Establish The Marble Weathering Mechanism In The Alhambra Of Granada (Spain), M. A. Bello, L. Martín, A. Martín

Scanning Microscopy

The weathering processes of the white marble from Macael quarries (Almeria, Spain) used in the Alhambra of Granada have been studied with the aim of establishing the weathering factors and mechanism. Unaltered quarry samples have been submitted to diverse accelerated weathering experiments and their morphology compared to the altered materials from the monument. The weathering process stages have been established and the degree of weathering in some monumental dependencies evaluated.


The Vascularization Of The Digestive Tract Studied By Scanning Electron Microscopy With Special Emphasis On The Teeth, Esophagus, Stomach, Small And Large Intestine, Pancreas, And Liver, S. Aharinejad, A. Lametschwandtner, P. Franz, W. Firbas Sep 1991

The Vascularization Of The Digestive Tract Studied By Scanning Electron Microscopy With Special Emphasis On The Teeth, Esophagus, Stomach, Small And Large Intestine, Pancreas, And Liver, S. Aharinejad, A. Lametschwandtner, P. Franz, W. Firbas

Scanning Microscopy

The periodontal vessels in adult rats show a ladder-like pattern; in guinea pigs molars, by contrast, they present a honey-comb pattern. The vascular architecture in human teeth seems to be similar to that of rabbits. In guinea pigs, rats, rabbits and humans esophagus circumferential vessels give off perforating vessels. In human esophagus the number and diameter of the vessels in the submucous venous plexus decrease from proximal to distal. In the stomach the subepithelial capillary network shows a honey-comb pattern reflecting the arrangement of the gastric pits. A local portal system between the gastric glands and the surface mucosal cells …


Scanning Electron Microscopy Of Corrosion Casting In Medicine, M. A. Konerding Jun 1991

Scanning Electron Microscopy Of Corrosion Casting In Medicine, M. A. Konerding

Scanning Microscopy

The aims of this review are: 1. to provide a bibliography of the publications that have used the corrosion casting technique; 2. to describe the advantages and limitations of the methodology; 3. to illustrate possible applications in the field of medicine, and 4. to highlight the significance of this method in the teaching of medical students. Thus, this paper is primarily focused on the scanning electron microscopical examination of vascular corrosion casts.

The unsurpassed three-dimensionality of the corrosion casting technique compared to any other means stands out in particular. This can be especially useful when complex vascular-anatomical relationships are present. …


The Hepatic Microcirculation In Experimental Cirrhosis A Scanning Electron Microscopy Study Of Microcorrosion Casts, E. Gaudio, L. Pannarale, M. Ripani, P. Onori, O. Riggio Apr 1991

The Hepatic Microcirculation In Experimental Cirrhosis A Scanning Electron Microscopy Study Of Microcorrosion Casts, E. Gaudio, L. Pannarale, M. Ripani, P. Onori, O. Riggio

Scanning Microscopy

The experimental model of liver cirrhosis induced by intragastric administration of CCl4 reproduces not only the histological picture of the postnecrotic cirrhosis but also its pathophysiological features.

Corrosion casts of livers affected by CCl4-induced cirrhosis show the loss of the lobular pattern. Once the cirrhosis has completely developed, the whole microvascular bed appears to be composed of groups of sinusoid nodules of diameters varying between 0.3 and 1.5 mm.. Pre- and post-sinusoidal vessels and anastomoses between the former and the latter are mainly located at the perinodular spaces.

This microvascular situation modifies the normal perfusion gradient within …


Timed Acid Bath Effects On Kidney Podocytes Prepared For Scanning Electron Microscopy, B. J. Moore, K. R. Holmes Feb 1991

Timed Acid Bath Effects On Kidney Podocytes Prepared For Scanning Electron Microscopy, B. J. Moore, K. R. Holmes

Scanning Microscopy

In perfusion fixation of dog kidney glomeruli, observation of tear fractured surfaces by scanning electron microscopy reveals the deposition of "debris" on the surface of glomerular visceral epithelium (podocytes) that is not deposited on other kidney tissue surfaces. It is of concern to remove this debris without damage to tissue surfaces. A 5 minute bath in 8N HCI (hydrochloric acid) following postfixation in 1% OsO4 (osmium tetroxide) removes only some of the debris. A 10 minute acid bath removes this debris without visible damage to podocyte surface structures such as cilia, plicae or blebs. A 20 minute acid bath …


Exxon Wyoming-Dakota Pipeline Segment 2 And Hartzog Draw Unit Co2 Projects Environmental Assessment, United States Department Of The Interior Bureau Of Land Management Jan 1991

Exxon Wyoming-Dakota Pipeline Segment 2 And Hartzog Draw Unit Co2 Projects Environmental Assessment, United States Department Of The Interior Bureau Of Land Management

Environmental Assessments (WY)

This Environmental Assessment (EA) has been prepared to analyze potential impacts from the proposed completion of Segment 2 of the Wyoming-Dakota pipeline and the Hartzog Draw Unit CO2 Project. The impacts of constructing the pipeline were originally analyzed in the Bairoil/Dakota CO2 Project's Environmental Impact Statement (EIS). The Record of Decision for that document was signed in February 1986, and construction on the first segment was completed in September 1986. This EA analyzes the possible environmental and socioeconomic impacts which could result from the proposals, and to solicit public comments and concerns. This document also serves as a request for …


Mineralized Matrix Production By Osteoblasts On Solid Titanium In Vitro, B. Lowenberg, R. Chernecky, A. Shiga, J. E. Davies Jan 1991

Mineralized Matrix Production By Osteoblasts On Solid Titanium In Vitro, B. Lowenberg, R. Chernecky, A. Shiga, J. E. Davies

Cells and Materials

Rat bone marrow cells were cultured on solid commercially pure titanium discs. Extracellular matrix (ECM) formed by the cells and the ECM/metal interface developed were examined by both scanning and transmission electron microscopy. The ECM most intimately associated with the substratum comprised afibrillar calcium phosphate globular accretions produced by the colonizing osteoblasts. The presence of calcium and phosphorus was confirmed by energy dispersive X-ray analysis. This initial layer acted as a site of anchorage for collagen fibres, produced by the osteoblasts. However, flaps of tissue elaborated during the culture period and manually reflected created a tissue division immediately above the …


Application Of Scanning Electron Microscopy And X-Ray Microanalysis To Investigate Corrosion Problems In Plain And Enamelled Three Piece Welded Food Cans, James E. Charbonneau Jan 1991

Application Of Scanning Electron Microscopy And X-Ray Microanalysis To Investigate Corrosion Problems In Plain And Enamelled Three Piece Welded Food Cans, James E. Charbonneau

Food Structure

Scanning Electron Microscopy (SEM) and X-Ray Microanalysis (EDS) have been used to investigate rapid detinning, pitting corrosion and cosmetic corrosion in plain tin plate food cans and pitting corrosion, underenamel corrosion, enamel flaking , sulfide black corrosion and stress corrosion cracking in enamelled food cans.

Through the use of SEM - EDS it was determined that (SnL a /FeK a) Y2 X -ray line intensities arc proportional to the tin coating weight on tinplate. The method was applied to a rapid detinning problem in canned grapefruit sections. The cause of the early corrosion failure was found to be reversed tinplate. …


Cytology Of Pollutant Metals In Marine Invertebrates: A Review Of Microanalytical Applications, J. A. Nott Dec 1990

Cytology Of Pollutant Metals In Marine Invertebrates: A Review Of Microanalytical Applications, J. A. Nott

Scanning Microscopy

X-ray microanalysis (XRMA) is customized for investigations of the metabolic and detoxification strategies of heavy metals taken by marine organisms from polluted environments. Sites of uptake, intracellular accumulation, transport and excretion are visualized, analysed and quantified . Cryopreparation techniques are required to prevent the translocation or loss from specimens of soluble metal species.

In marine invertebrates, metals are detoxified by systems of chemical binding and intracellular compartmentalization. XRMA investigations have concentrated on marine molluscs and crustaceans and even within these restricted groups there are marked inter-species differences in the biochemical and cytological processes which reduce metal bioavailability. Some detoxification systems …


A Straightforward Scanning Electron Microscopy Technique For Examining Non-Metal Coated Dental Hard Tissues, S. M. Mccormack, F. J. Tormo, J. D. B. Featherstone Oct 1990

A Straightforward Scanning Electron Microscopy Technique For Examining Non-Metal Coated Dental Hard Tissues, S. M. Mccormack, F. J. Tormo, J. D. B. Featherstone

Scanning Microscopy

Modifications to the standard operating settings for accelerating voltage , condenser lens current, scan rate, working distance and tilt on the conventional scanning electron microscope (SEM) enabled non-metal coated dental hard tissues and synthetic apatite pellets to be viewed free of charging effects . Well -resolved images at magnifications as high as 35,000x were achieved using accelerating voltages less than 5 kV . The methodology detailed here allowed for serial SEM examination of the same sample at various points during an experimental procedure , and may be applied to other sample types. The procedure is non-destructive to the sample and …


Microcirculatory Pathways And Blood Flow In Spleen: New Insights From Washout Kinetics, Corrosion Casts, And Quantitative Intravital Videomicroscopy, A. C. Groom, E. E. Schmidt, I. C. Macdonald Oct 1990

Microcirculatory Pathways And Blood Flow In Spleen: New Insights From Washout Kinetics, Corrosion Casts, And Quantitative Intravital Videomicroscopy, A. C. Groom, E. E. Schmidt, I. C. Macdonald

Scanning Microscopy

The dynamics of splenic microcirculatory blood flow and the role of the spleen with respect to red blood cells (RBCs) have been elucidated by means of several different experimental approaches. First, the organ was treated as a 'black box' and input/output relationships were studied, such as the kinetics of RBC and plasma washout during Ringer perfusion. Second, micro-corrosion casts were prepared from minimal amounts of injected material, such that 'fast' pathways for flow were selectively identified. Third, high-resolution video-microscopy was carried out in rat and mouse spleens transilluminated in vivo, with subsequent quantitative analysis of the data. New insights were …


Scanning Electron Microscopy Of Vascular Corrosion Casts - Technique And Applications: Updated Review, A. Lametschwandtner, U. Lametschwandtner, T. Weiger Sep 1990

Scanning Electron Microscopy Of Vascular Corrosion Casts - Technique And Applications: Updated Review, A. Lametschwandtner, U. Lametschwandtner, T. Weiger

Scanning Microscopy

The present paper states very briefly the main steps leading to the technique of scanning electron microscopy (SEM) of vascular corrosion casts. From the terms presently used (injection method, microcorrosion cast, injection replica, vascular corrosion cast, vascular cast) the use of "vascular corrosion cast" for lymphatic and blood vessels is recommended. Specification and pretreatment (kind, volume, dosage of anticoagulants, vasoactive substances and spasmolytica used) of the animals examined are referenced as they are available from the literature. The recommendation is given to pay more attention to these parameters than done so far. The steps necessary for producing reasonable and suitable …


Scanning Electron Microscopic Studies Of The Oral Tissue Responses To Dental Implants, David E. Steflik, Ralph V. Mckinney, Allen L. Sisk, Gregory R. Parr, David L. Koth Sep 1990

Scanning Electron Microscopic Studies Of The Oral Tissue Responses To Dental Implants, David E. Steflik, Ralph V. Mckinney, Allen L. Sisk, Gregory R. Parr, David L. Koth

Scanning Microscopy

Scanning electron microscopy ( SEM) and its associated technologies have proven invaluable in elucidating the interfacial oral tissue responses to dental implants. Since the dental implant must extend from the mandibular or maxillary jaw, through the oral mucosa, and into the oral cavity, these tissue responses include epithelium, connective tissue and bone. The continual occlusal forces acting upon these tissues reinforce the dynamic character of these tissue responses. Immediately upon implantation, a healing phase begins as a response to the implanted biomaterial. Following this immediate response a longer healing phase occurs, beginning approximately 1 week after implantation, resulting in the …


Kidney Structure Investigations Using Scanning Electron Microscopy Of Corrosion Casts - A State Of The Art Review, H. Ditrich, H. Splechtna Sep 1990

Kidney Structure Investigations Using Scanning Electron Microscopy Of Corrosion Casts - A State Of The Art Review, H. Ditrich, H. Splechtna

Scanning Microscopy

The corrosion casting technique using acrylic resins in the scanning electron microscope (SEM), was originally developed to investigate renal microvascular structure and is now also successfully used in studies on various other organs. However, in the last two decades nearly 100 papers have been published on the renal vascular anatomy of various taxa of vertebrates or on pathomorphological structures of kidneys, using this technique. Analyzing these works, trends and developments in this field can be summed up as follows: The majority of studies are anatomical works on the vascular system of kidneys from all vertebrate classes. In addition, experimental pathological …


Pegsat - First Pegasus Payload, Robert Pincus, Jack Pownell, James Rast Aug 1990

Pegsat - First Pegasus Payload, Robert Pincus, Jack Pownell, James Rast

Small Satellite Conference

Pegsat was designed, built and tested in slightly more than 6 months to meet the planned launch date for the first launch of the Pegasus vehicle. The primary objective of this multifunction spacecraft was to obtain environmental data from the Pegasus vehicle for use in designing future satellite busses. Taking full advantage of the opportunity, Pegsat also deployed a small Navy experimental satellite, and conducted scientific experiments over Northern Canada in support of the upcoming CRRES mission.