Open Access. Powered by Scholars. Published by Universities.®

Digital Commons Network™

Open Access. Powered by Scholars. Published by Universities.®

Utah State University

Discipline
Keyword
Publication Year
Publication
Publication Type

Articles 481 - 510 of 745

Full-Text Articles in Entire DC Network

Nanometer-Scale Synthesis And Atomic-Scale Modification With The Scanning Tunneling Microscope, Reginald M. Penner Aug 1993

Nanometer-Scale Synthesis And Atomic-Scale Modification With The Scanning Tunneling Microscope, Reginald M. Penner

Scanning Microscopy

The structure or composition of a surface may be locally altered in either of two fundamental ways using the scanning tunneling microscope (STM). A modification of the surface may be induced resulting in the rearrangement and/or removal of surface atoms, or in the transfer of atoms from the tip to the sample surface. In many recent experiments, the modification of surfaces has involved a single atom or an ensemble of a few atoms. Alternatively, the localized synthesis of a new material from reactants external to the STM tip and sample can be induced using at least three experimental strategies. A …


New Methods For Depositing And Imaging Molecules In Scanning Tunneling Microscopy, Victor N. Morozov, Nadrian C. Seeman, Neville R. Kallenbach Aug 1993

New Methods For Depositing And Imaging Molecules In Scanning Tunneling Microscopy, Victor N. Morozov, Nadrian C. Seeman, Neville R. Kallenbach

Scanning Microscopy

Methods and apparatus are described to deposit and image molecules by scanning tunneling microscopy (STM) under an inert atmosphere. Three methods of applying molecules have been evaluated: equilibrium adsorption from the vapor phase, sublimation, and electrospraying. Using these methods, a variety of organic and biopolymer molecules have been deposited and imaged on graphite and on gold (111), grown epitaxially on mica. Compared with alternatives, such as the use of high vacuum apparatus or glove boxes, these procedures offer some important advantages: they are inexpensive, convenient, and more rapid. Mercaptoethanol, ethanolamine, ethanol, acetic acid, and water produce two-dimensional crystalline adlayers on …


Comparative Aspects Of Splenic Microcirculatory Pathways In Mammals: The Region Bordering The White Pulp, E. E. Schmidt, I. C. Macdonald, A. C. Groom May 1993

Comparative Aspects Of Splenic Microcirculatory Pathways In Mammals: The Region Bordering The White Pulp, E. E. Schmidt, I. C. Macdonald, A. C. Groom

Scanning Microscopy

Splenic microcorrosion casts prepared using minimal volumes of material show that most of the flow passes through the region bordering the white pulp. However, the nature of these microcirculatory pathways has received little attention. We have studied these in dog, cat, rat, mouse, and normal versus diseased human spleens. In all 5 species, a marginal sinus (MS) of anastomosing vascular spaces 5-10 μm thick lies between the white pulp and marginal zone (MZ). The morphology differs between species and the MS is absent in immune thrombocytopenia. The MS fills by circumferential flow before blood passes outward to the MZ. Many …


Casting With Mercox-Methylmethacrylic Acid Mixtures Causes Plastic Sheets On Elastic Arteries. A Scanning And Transmission Electron Microscopic Study, Seyedhossein Aharinejad, Peter Böck May 1993

Casting With Mercox-Methylmethacrylic Acid Mixtures Causes Plastic Sheets On Elastic Arteries. A Scanning And Transmission Electron Microscopic Study, Seyedhossein Aharinejad, Peter Böck

Scanning Microscopy

Lungs and systemic vessels of rats were cast with Mercox, both undiluted and diluted with monomeric methylmethycrylate (MMA; v:v/4:1), and studied by scanning electron microscopy (SEM). A sheet, less than 5 μm thick, surrounded the surface of cast pulmonary arteries and the aorta, when using diluted Mercox. This envelope was absent when casts were prepared with undiluted Mercox. Transmission electron microscopy (TEM) of unmacerated cast arteries showed all constituents of the vascular wall. Sections of thoroughly macerated vascular casts, however, still showed elastic lamellae in the vascular wall region, whereas muscular components and endothelial lining were completely digested. It is …


Sensory And Functional Properties Of Wheat Stored Under Home Conditions, Marilyn M. Shumway May 1993

Sensory And Functional Properties Of Wheat Stored Under Home Conditions, Marilyn M. Shumway

All Graduate Theses and Dissertations, Spring 1920 to Summer 2023

Samples of wheat that had been stored in homes up to 48 years were collected with information about age and storage conditions. Germination, weight per bushel, protein, moisture, grade, and aroma were investigated. Volumes of gluten balls and bread made from ground whole wheat samples were measured. Sensory attributes of bread were evaluated by Quantitative Descriptive Analysis (QDA) for eight flavor and seven texture characteristics. Because of the tremendous variation in samples, generalizations on cause and effect are difficult to make. No one criterion was a perfect indicator of quality. A high percentage of germination was one of the better …


Preliminary Public Health Assessment: Petrochem Recycling Corporation/Ekotek Salt Lake City, Salt Lake County, Utah, Agency For Toxic Substances And Disease Registry, Divisoin Of Health Assessment And Consultation Apr 1993

Preliminary Public Health Assessment: Petrochem Recycling Corporation/Ekotek Salt Lake City, Salt Lake County, Utah, Agency For Toxic Substances And Disease Registry, Divisoin Of Health Assessment And Consultation

All U.S. Government Documents (Utah Regional Depository)

The Petrochem/EkoTek site was operated by several owners as a refinery from 1953 until 1978 and as a hazardous waste storage treatment facility and a petroleum recycling facility from 1978 through 1988. Removal of essentially all petroleum products and hazardous wastes in tanks and drums was accomplished from 1988 - 1991. The process that will lead to the complete clean-up of the facility is ongoing. The site was added to the National Priorities List (NPL) in October 1992. Exposure of humans to contaminants in soil and air is thought to have occurred near Petrochem. The source(s) of those contaminants in …


Microvascular System Of The Human Fetal Inner Ear: A Scanning Electron Microscopic Study Of Corrosion Casts, A. J. Miodoński, J. Gorczyca, M. Nowogrodzka-Zagórska, J. A. Litwin, J. Składzień Mar 1993

Microvascular System Of The Human Fetal Inner Ear: A Scanning Electron Microscopic Study Of Corrosion Casts, A. J. Miodoński, J. Gorczyca, M. Nowogrodzka-Zagórska, J. A. Litwin, J. Składzień

Scanning Microscopy

The vascular system of the inner ear was investigated in 18-21 weeks old human fetuses, using the corrosion cast technique in scanning electron microscopy. At that developmental stage, vascularization of the cochlea and semicircular canals shows a pattern very similar to that described for adults. The most important differences which can be regarded as fetal features include: (1) denser limbus vessels, (2) the marginal vessels of the spiral lamina appearing as irregular network which shows a less clear arcade-like arrangement, (3) some radiating arterioles of the spiral lamina and marginal vessels possessing connections with the vascular system of the external …


Improved Tissue Corrosion Of Vascular Casts: A Quantitative Filtration Method Used To Compare Tissue Corrosion In Various Concentrations Of Sodium And Potassium Hydroxide, Paul A. Sims, Ralph M. Albrecht Mar 1993

Improved Tissue Corrosion Of Vascular Casts: A Quantitative Filtration Method Used To Compare Tissue Corrosion In Various Concentrations Of Sodium And Potassium Hydroxide, Paul A. Sims, Ralph M. Albrecht

Scanning Microscopy

In this study, we compare weights of filter retained material (11 μm particle retention) after solubilization and filtration of unfixed, un-perfused tissue (fat, liver and trachea) in sodium and potassium hydroxide (1% , 5%, 10% and 20% weight/volume, w/v) at 8, 24 and 48 hour time points at 45°C. Three detergents [1% Triton-X-100 (volume/volume, v/v), 1% 7X (v/v), 1% Terg-A-Zyme (w/v)] used in combination with hydroxide were evaluated for use in solubilizing fat. Additionally, vascular casts from mouse kidneys were corroded to test the practical effectiveness of corroding solutions on resin infused tissue.

Five percent KOH for eight hours proved …


The Vascularization Of The Kidney Of The Eel (Anguilla Anguilla - Osteichthyes) In The Freshwater Habitat, Hans Ditrich, Heinz Splechtna Feb 1993

The Vascularization Of The Kidney Of The Eel (Anguilla Anguilla - Osteichthyes) In The Freshwater Habitat, Hans Ditrich, Heinz Splechtna

Scanning Microscopy

The renal vascular system of eels (Anguilla anguilla L.) in freshwater has been investigated using light-, transmission electron-, and scanning electron microscopy of vascular corrosion casts and critical-point dried specimens. The morphology of the kidney exhibits a highly evolved, unpaired, spindle-shaped form. The renal tissue extends partially into a recessus dorso-caudal to the anus. Renal glomeruli are comparatively large (100.8 μm +/-17 standard deviation) and well vascularized. They are arranged in grape-like clusters around the intrarenal arteries. Closely neighbouring glomeruli can be surrounded by incompletely separated Bowman's capsules sharing the same renal tubule. The peritubular capillary plexus is …


Scanning Electron Microscopy Of Styrene-Methylethylketone Casts Of The Airway And The Arterial System Of The Lung, Teruyuki Hojo Jan 1993

Scanning Electron Microscopy Of Styrene-Methylethylketone Casts Of The Airway And The Arterial System Of The Lung, Teruyuki Hojo

Scanning Microscopy

The method of making casts of airways and the pulmonary arterial system using a styrene polymer resin is described. A human and a dog were used as models. The viscosity of this resin ranges between 40 and 60 dPa/s at 24°C. The elastic rubber tube used for resin injection allows a constant perfusion pressure, i.e., 44 mm Hg and 110 mm Hg for airway and vascular filling, respectively. The casts obtained using this method are suitable both for macro- and microscopic analysis. Shrinkage during polymerization is minimal. Moreover, a preceding lavage is not necessary. Scanning electron microscopy (SEM) of cast …


Food Microscopy And The Nutritional Quality Of Cereal Foods, Suk Hing Yiu Jan 1993

Food Microscopy And The Nutritional Quality Of Cereal Foods, Suk Hing Yiu

Food Structure

The nutritional quality of cereal foods is directly related to the nature of nutrient storage in cereal grains. Most cereal nutrients, such as carbohydrates and minerals , are st ructurally bound. Processing alters the structural organization of the cereal grain. Results obtained from many nutritional studies indicate that the structure and physical form of a cereal food greatly influence the availability of its nutrients.

Using oats and wheat as examples, this review demonstrates how microscopy contributes to understanding the relationship between cereal structures and the availability of nutrients in cereal foods. Various forms of food microscopy play important roles in …


Recent Developments In Multichannel Raman Microprobing, J. Barbillat, M. Delhaye, E. Da Silva Jan 1993

Recent Developments In Multichannel Raman Microprobing, J. Barbillat, M. Delhaye, E. Da Silva

Scanning Microscopy

This paper reviews the capabilities of multichannel Raman microprobing instruments with emphasis on some major innovative progress recently proposed which looks promising for the development of new fields of application. This new progress includes: confocal Raman microanalysis that provides better spatial resolution and background rejection, confocal Raman mapping that revitalizes the field of Raman imaging pioneered by us 20 years ago, the coupling of molecular Raman microanalysis to elemental electron microprobe, and finally, Raman spectroscopy with near-infrared excitation which permits avoiding the fluorescence limitation of visible Raman spectroscopy.


Evaluation Of Drug Delivery Systems By Electron Microscopy Techniques, Y. V. Pathak, V. D. Labhashetwar Jan 1993

Evaluation Of Drug Delivery Systems By Electron Microscopy Techniques, Y. V. Pathak, V. D. Labhashetwar

Cells and Materials

This review covers the applications of electron microscopic techniques to the characterization and evaluation of drug delivery systems. Various electron microscopic (EM) related techniques such as transmission electron microscopy, scanning electron microscopy (SEM), SEM with energy dispersive X-ray microanalysis, and freeze-fracture electron microscopy are extensively used for this purpose. Microcapsules, microspheres, nanocapsules, liposomes , polymeric carriers and other drug delivery systems are characterized using EM related techniques for their surface topography, size and shape analysis, biodegradation, in vitro - in vivo evaluation and drug excipient interactions and characterization. Electron microscopy methods are very useful in understanding the mechanism of drug …


In-Vivo Reactions In Some Bioactive Glasses And Glass-Ceramics Granules, A. M. Gatti, T. Yamamuro, L. L. Hench, O. H. Andersson Jan 1993

In-Vivo Reactions In Some Bioactive Glasses And Glass-Ceramics Granules, A. M. Gatti, T. Yamamuro, L. L. Hench, O. H. Andersson

Cells and Materials

Two different bioactive glasses and one glass-ceramic were implanted as granules for 2 months in rabbit muscle and for 5 months in sheep jaw in order to study the influence of the biological surroundings on the reactions of the materials.

Scanning electron microscope and energy dispersive X-ray microanalysis showed that a calcium and phosphorous-rich (CaP) surface layer (adjacent to a silicon rich-layer) forms on both glasses in both implantation sites. The glass-ceramic developed only a CaP layer. A chemical process of degradation was more evident in muscle, even though the implantation time was shorter than that in bone. For all …


Microstructural Enhancement Of Dental Composite And Ceramic Materials By Plasma Etching, H. J. Mueller, M. S. Bapna Jan 1993

Microstructural Enhancement Of Dental Composite And Ceramic Materials By Plasma Etching, H. J. Mueller, M. S. Bapna

Cells and Materials

Radio frequency plasma etching of a selected number of dental materials , including glass filled polymeric composites, alumina reinforced ceramic, glass ionomer, and zinc oxide eugenol enhanced microstructural detail for scanning electron microscopy analyses. All four plasmas, argon , oxygen, carbon tetrafluoride (CF4), and CF4 + 4% 0 2 , proved effective, but the latter was the most effective. The etching of all materials , except the ceramic, was accomplished by the selective removal of a polymeric component. For the glass filled composites , this involved removal of the Bis-GMA matrix resin, leaving the filler particles in relief. For a …


Computer Methodology For Transportation Agencies To Screen Technologies For Hazardous Waste Remediation, William J. Grenney, Ravi Kumar Penmetsa Jan 1993

Computer Methodology For Transportation Agencies To Screen Technologies For Hazardous Waste Remediation, William J. Grenney, Ravi Kumar Penmetsa

Reports

Executive Summary: Many pathways exist for transportation agencies and other public and private agencies to become responsible for sites contaminated by hazardous wastes. As a reult, agencies frequently face a multitude of lega, regulatory, financial, technical, and health risk problems. When transportation agencies become involved in the remediation of hazardous waste sites, the common practice is to hire consultants and contractors for the clean up process. Because the field of hazardous waste site remediation is changing so rapidly, agency personnel evaluating the consultant's recommendations need to ahve access to the most recent regulatory and remediation information. Early stages of the …


A Tutorial And Comprehensive Bibliography On The Identification Of Foreign Bodies Found In Food, D. F. Lewis Jan 1993

A Tutorial And Comprehensive Bibliography On The Identification Of Foreign Bodies Found In Food, D. F. Lewis

Food Structure

The paper presents a philosophical approach to the investigation of foreign body incidents in food. The suggested procedure has similarities with "key" procedures used for taxonomy. However, the wide diversity of materials encountered and the need to determine something of the history of the offending item demands modifications to this process. The categorisation may be made on instinct or experience, and appropriate confirmatory tests will be applied in the light of the initial categorisation. Cardinal rules are proposed: firstly , the receipt of the items should be well documented; and secondly, the initial observations should be as non-destructive as possible. …


A Scanning Electron Microscopic Study Of The Chick Chorioallantoic Membrane: Cell Death And The Involvement Of Oxygen Free Radicals, A. Easterling, G. J. Burton, J. N. Skepper, M. H. Nasr-Esfahani Dec 1992

A Scanning Electron Microscopic Study Of The Chick Chorioallantoic Membrane: Cell Death And The Involvement Of Oxygen Free Radicals, A. Easterling, G. J. Burton, J. N. Skepper, M. H. Nasr-Esfahani

Scanning Microscopy

Cell death is a normal feature within the chick chorioallantoic membrane, occurring principally between days 10 and 14 of incubation.

Samples of chorioallantoic membrane were obtained on days 6, 8, 10, 12 and 14 of incubation, after the creation of artificial air chambers on day 3. These were examined by scanning electron microscopy (SEM), transmission electron microscopy (TEM) after staining for acid phosphatase activity, and by light microscopy after demonstrating oxygen free radicals with nitro blue tetrazolium. On day 6, small defects in the plasmalemma, approximately 200 nm in diameter, could be seen by SEM. A sequence of events leading …


Microvascular Architecture Of The Filiform Papillae In Primates And Insectivores, S. Okada, Y. Ohta, N. Matsukawa, S. Sugioka Dec 1992

Microvascular Architecture Of The Filiform Papillae In Primates And Insectivores, S. Okada, Y. Ohta, N. Matsukawa, S. Sugioka

Scanning Microscopy

The microvascular architecture of filiform papillae was investigated under a scanning electron microscope in man, Japanese monkeys, common squirrel monkeys, common marmosets, common tree shrews, large Japanese moles and dwarf shrews utilizing microvascular corrosion casts. Filiform papillae were circularly arranged in primates, and each of them was supplied by a hairpin capillary loop. These papillae sometimes were aggregated. The filiform papillae of Japanese monkeys exhibited markedly locational differences on the lingual dorsum and were supplied by circularly arranged capillary loops or by an intrapapillary capillary network. Small filiform papillae were located on an epithelial eminence in the lingual radix, each …


Review: Morphological Changes Associated With Endolymphatic Hydrops, K. C. Horner Nov 1992

Review: Morphological Changes Associated With Endolymphatic Hydrops, K. C. Horner

Scanning Microscopy

Endolymphatic hydrops of the inner ear is identified as a swelling of the endolymphatic spaces. This morphopathology in man can only be confirmed at postmortem examination although it is believed to underlie the auditory dysfunction and vestibular disturbances associated with Menière's disease. This is an illusive inner ear disorder characterized typically by the fluctuant hearing loss, tinnitus and episodes of vertigo. Menière's disease remains a major problem in otorhinolaryngology since the cause of the disease is not known and various treatments are recommended, often with unsatisfactory results. Experimentally induced endolymphatic hydrops in the animal model has been developed in order …


Mercox®-Methylmethacrylic Acid Mixture Penetrates Into Cells. A Scanning And Transmission Electron Microscopic Study, S. Aharinejad, P. Böck Nov 1992

Mercox®-Methylmethacrylic Acid Mixture Penetrates Into Cells. A Scanning And Transmission Electron Microscopic Study, S. Aharinejad, P. Böck

Scanning Microscopy

During preparation of vascular casts using mixtures of Mercox® and methylmethacrylic acid for scanning electron microscopy, occasionally irregular structures were observed adhering to otherwise well prepared corrosion casts. These artifacts were further analyzed in sections of cast preparations. The bizarre-shaped structures varied in size and were often tightly connected to vascular casts; they withstood KOH maceration and cleaning with formic acid. The persistence of biological material, connective tissue fibers and cells or cellular fragments, became obvious in ultrathin sections. Transmission electron microscopy also showed inhomogeneity of the polymerized casting medium (Mercox®-methylmetbacrylate mixture; v/v: 4:1). An unidentified com-pound of this resin …


Microvasculature Of Normal And Hydropic Labyrinth, Yoshiaki Nakai, Haruhiko Masutani, Makoto Moriguchi, Kazuhiro Matsunaga, Akihumi Kato, Hitoshi Maeda Oct 1992

Microvasculature Of Normal And Hydropic Labyrinth, Yoshiaki Nakai, Haruhiko Masutani, Makoto Moriguchi, Kazuhiro Matsunaga, Akihumi Kato, Hitoshi Maeda

Scanning Microscopy

The microvasculature of the inner ear in guinea pigs and humans was observed with a scanning electron microscope using corrosion casting method. Alterations in the inner ear vasculature which occurred in association with experimental endolymphatic hydrops were also investigated. The results thus obtained are summarized as follows:

1. In the cochlea and vestibule, the arteries, coiled arterioles, and the veins are endowed with their respective characteristic morphologic features and play a role in the regulatory mechanisms of circulation.

2. The point in humans which is most different from guinea pigs was that coiled arterioles in the cochlea and the coil-like …


The Splenic Microvasculature Of The Red-Eared Turtle (Chrysemys Scripta Elegans): A Study Concerning The Question Whether The Circulation Is Anatomically Open Or Closed, R. Blumer, H. Ditrich, H. Splechtna Oct 1992

The Splenic Microvasculature Of The Red-Eared Turtle (Chrysemys Scripta Elegans): A Study Concerning The Question Whether The Circulation Is Anatomically Open Or Closed, R. Blumer, H. Ditrich, H. Splechtna

Scanning Microscopy

The splenic microvasculature of the turtle Chrysemys scripta elegans was studied by means of scanning electron microscopy of vascular corrosion casts and critical point dried tissue. In addition light- and transmission electron microscopic investigations were carried out. Within the organ the arteries are surrounded by periarterial lymphoid sheaths. The majority of the arterial capillaries, which emerge from these central arteries have open endings within the reticular meshwork of the red pulp. Approximately 10% of the capillaries directly connect with the venous origins. Since these venous capillaries of C. scripta elegans resemble those of nonsinusal mammalian spleens we termed them pulp …


Direct Visualization And Silver Enhancement Of Ultra-Small Antibody-Bound Gold Particles On Immunolabeled Ultrathin Resin Sections, York-Dieter Stierhof, Bruno M. Humbel, Rene Hermann, Max T. Otten, Heinz Schwarz Sep 1992

Direct Visualization And Silver Enhancement Of Ultra-Small Antibody-Bound Gold Particles On Immunolabeled Ultrathin Resin Sections, York-Dieter Stierhof, Bruno M. Humbel, Rene Hermann, Max T. Otten, Heinz Schwarz

Scanning Microscopy

Ultra-small gold colloids bound to immunolabeled ultrathin resin sections were visualized using transmission, scanning, and scanning transmission electron microscopy (TEM, SEM, STEM). The best marker contrast is obtained in a field emission STEM (200 kV) equipped with a high-angle annular dark-field (HAADF) detector. HAADF STEM renders possible the simultaneous visualization of ultra-small gold and ultrastructural details in unstained resin sections, and an overall presentation of a labeled E. coli cell.

For routine work, an enhancement step is a prerequisite for easy detection of bound marker molecules. Five different silver enhancing solutions were tested for their suitability for ultra-small gold intensification. …


Increasing Space Access Availability For Small Payloads: The Pacastro Launch Vehicle, Rick Fleeter, Frank Mcloughlin, Ray Millst Sep 1992

Increasing Space Access Availability For Small Payloads: The Pacastro Launch Vehicle, Rick Fleeter, Frank Mcloughlin, Ray Millst

Small Satellite Conference

This paper familiarizes the Small Satellite community with the capabilities and advantages offered by the PacAstro launch vehicle and its applications to low-cost launch needs. At a projected cost of $5M per launch, the 2-stage, pressure-fed liquid fueled vehicle is designed to transport 225 kg (500 Ibm) to a 750 km (405 nm) altitude circular polar orbit, or to a 1200 km (650 nm) altitude circular equatorial orbit. The smooth burning engine provides a gentle vibration environment and can be throttled, shut-down, and restarted to accommodate accurate orbit insertion. The large 1.5 m 10 and 2.4 m long payload volume …


Microwear Studies Of Early African Hominid Teeth, Pierre-François Puech Sep 1992

Microwear Studies Of Early African Hominid Teeth, Pierre-François Puech

Scanning Microscopy

Studies of microwear on fossil hominid teeth have become an important approach in paleoanthropology. Since there are very few samples of early hominids from East Africa with suitable teeth, this paper presents a review of the occurrence of some dental wear characteristics to provide a data base for reconstructing the diet of the early hominids.

Distinctive microwear features such as furrows, crenulations, stress lines and deep grooves, are interpretive tools that can be used in a biomechanical approach. Occurrence of the same dental microwear patterns in extant species with known dietary differences is indicative of foods that have probably been …


Copernicus - Lunar Surface Mapper, Frank Redd, Shaun Anderson Sep 1992

Copernicus - Lunar Surface Mapper, Frank Redd, Shaun Anderson

Small Satellite Conference

The Utah State University (USU) 1991-92 Space Systems Design Team has designed a Lunar Surface Mapper (LSM) to parallel the development of the NASA Office of Exploration lunar initiatives. USU students named the LSM "Copernicus" after the 16th Century Polish astronomer, for whom the large lunar crater on the face of the moon was also named. The top level requirements for the Copernicus LSM are to produce a digital map of the lunar surface with an overall resolution of 12 meters (39.4 ft). It will also identify specified local surface features/areas to be mapped at higher resolutions by follow-on missions. …


Vascular Anatomy Of The Pig Kidney Glomerulus: A Qualitative Study Of Corrosion Casts, B. J. Moore, Kenneth R. Holmes, Lisa Xuemin Xu Aug 1992

Vascular Anatomy Of The Pig Kidney Glomerulus: A Qualitative Study Of Corrosion Casts, B. J. Moore, Kenneth R. Holmes, Lisa Xuemin Xu

Scanning Microscopy

Pig kidney glomerular vascular anatomy was studied by scanning electron microscopy of vascular corrosion casts. A generalized vascular architecture is presented to describe the pig kidney glomerulus based upon the observation of 3,800 vascular cast glomeruli. The relative simplicity of the pig glomerular vascular architecture has allowed the characterization of different vascular segments more completely than has been possible in other mammals. Based upon relationships to the afferent arteriole, a nomenclature and definition of primary, secondary, tertiary and anastomotic vessels is proposed for the distributing vessels comprising the glomerular tuft. The existence and formation of a large central hemispheric vessel …


Luminal Constrictions On Corrosion Casts Of Capillaries And Postcapillary Venules In Rat Exocrine Pancreas Correspond To Pericyte Processes, Seyedhossein Aharinejad, Peter Böck Aug 1992

Luminal Constrictions On Corrosion Casts Of Capillaries And Postcapillary Venules In Rat Exocrine Pancreas Correspond To Pericyte Processes, Seyedhossein Aharinejad, Peter Böck

Scanning Microscopy

The rat exocrine pancreas was studied as a model to demonstrate morphological features of different types of capillaries, using scanning electron microscopy of vascular corrosion casts and transmission electron microscopy of tissue sections. Two types of capillaries were discerned. The first type represents less undulated, slender, straight capillaries with numerous, shallow, circular or semilunar furrows on its cast's surface. In tissue sections, this type probably corresponds to non-fenestrated capillaries. The numerous grooves on its cast correspond to pericyte processes beneath the endothelial lining. The second type comprises capillaries of an undulated course and variable diameter with less numerous furrows. In …


Appearance Of Venous Sphincters In The Pulmonary Microvascular Bed Of Normotensive And Spontaneously Hypertensive Rats, Seyedhossein Aharinejad, Peter Böck Aug 1992

Appearance Of Venous Sphincters In The Pulmonary Microvascular Bed Of Normotensive And Spontaneously Hypertensive Rats, Seyedhossein Aharinejad, Peter Böck

Scanning Microscopy

The appearance of pulmonary venous sphincters was studied in normotensive and spontaneously hypertensive rats using scanning electron microscopy of microvascular corrosion casts and transmission electron microscopy of tissue sections. Vascular casts were prepared either after lavage with Tyrode solution or after glutaraldehyde prefixation. Pronounced pulmonary venous sphincters were more frequently identified in spontaneously hypertensive rats as compared to corresponding circular indentations in normotensive rats. Tissue sections established venous sphincters in hypertensive animals as consisting of multiple layers of smooth muscle cells in the venous walls. We did not observe any autonomic nerve terminals in close proximity to these bundles of …