Advertising Brochure: Four Drive Model E, Nebraska Tractor Test Lab Jan 1929

Advertising Brochure: Four Drive Model E, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Advertising Brochure: Baker 22-40, Nebraska Tractor Test Lab Jan 1929

Advertising Brochure: Baker 22-40, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 156: Mccormick Deering 15-30, Nebraska Tractor Test Lab Jan 1929

Test 156: Mccormick Deering 15-30, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 157: Rock Island G-2, 15-25, Nebraska Tractor Test Lab Jan 1929

Test 157: Rock Island G-2, 15-25, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 155: Case Model L 26-40, Nebraska Tractor Test Lab Jan 1929

Test 155: Case Model L 26-40, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 157: Rock Island Model G2 15-25 (Distillate), Nebraska Tractor Test Lab Jan 1929

Test 157: Rock Island Model G2 15-25 (Distillate), Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 158: Rock Island Model G2 18-30 (Gasoline), Nebraska Tractor Test Lab Jan 1929

Test 158: Rock Island Model G2 18-30 (Gasoline), Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 160: Caterpiller Model 10 10-15, Nebraska Tractor Test Lab Jan 1929

Test 160: Caterpiller Model 10 10-15, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 167: Case Model C 17-27, Nebraska Tractor Test Lab Jan 1929

Test 167: Case Model C 17-27, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Reaction Of Metallic Iron And Copper Sulphate In The Flotation Of Sphalerite, Charles Wilson Ambler Jan 1929

Reaction Of Metallic Iron And Copper Sulphate In The Flotation Of Sphalerite, Charles Wilson Ambler

Masters Theses

"Copper sulphate is a common flotation reagent for blende ores. Metallic iron is also present in the mill circuit and a reaction between the iron and the salt would be in accord with well known chemistry. The abundance of metallic iron in a flotation feed may be noted by the examination of any feed. It originates, first of all, in the mine, then the coarse crushing machines contribute their share, and finally the fine grinding medium is a large contributor. If the grinding is with cast iron balls in amount of metallics is greater than when steel is used. In …


A Study Of The Basal Cherokee In The Rolla Area, Thomas Daniel Murphy Jan 1929

A Study Of The Basal Cherokee In The Rolla Area, Thomas Daniel Murphy

Masters Theses

"The occurrence of outliers of Pennsylvanian age, probably Cherokee, in and about Rolla has long been known. The Bureau of Geology and Mines and the Department of Geology of the School of Mines at Rolla have been greatly interested in the many stratigraphic problems presents. The writer has, therefore, undertaken field and laboratory studies of certain of these problems"--Introduction, page [1].


Elutriation Of Flotation Products, Guenther Walter Frotscher Jan 1929

Elutriation Of Flotation Products, Guenther Walter Frotscher

Masters Theses

"Since the first application of the flotation process in ore dressing practice, engineers have been busy solving the most delicate relations of metal distribution in the minerals to be treated...The desire for more information was the reason for research concerning the mineral distribution in fine flotation material with particular attention to the development of a suitable laboratory method of hydraulic classification or, as it is especially called, elutriation"--Introduction, page 1-4.


The Sensitivity Of The Ortho-Tolidine Test For Free Chlorine In Milk Serum, Estelle Downer Jun 1928

The Sensitivity Of The Ortho-Tolidine Test For Free Chlorine In Milk Serum, Estelle Downer

Bachelors’ Theses

In the Journal of Industrial and Engineering Chemistry for November, 1913, J.W. Ellms and S.J. Hauser introduced the ortho-tolidine test for the detection of minute quantities of free chlorine in water. Antecedant to the experimentation of the above men with ortho-tolidine, the starch-iodide test ·was universally used for the· detection of free chlorine. In this test, the chlorine is calculated by liberating iodine from potassium iodide by the available chlorine, and the iodine being titrated with sodium thio sulfate. starch solution is used as the indicator. However, this particular method offers difficulties in the presence of minute quantities of chlorine …


Graphical Calculation And Computation, Alice Hudson Vallier Jun 1928

Graphical Calculation And Computation, Alice Hudson Vallier

Bachelors’ Theses

The word ’’graph” has lately become a part of the active vocabulary of the ordinarily educated person of today. We may say lately because even fifty years ago the use of the graph to represent data was limited to the knowledge of a few theorizing mathematicians and the miscellaneous disorganized usage of some practical mechanics, engineers, business men and statisticians. The situation is not that fifty years ago the rudiments of graphing were not identical with the bases of graphing data today, at least by such simple methods as are commonly employed in periodicals and newspapers for the enlightenment of …


A Study Of The Temperature Behavior Of Various Liquids When Subjected To Pressures Ranging Between One And One Hundred Pounds Absolute, Jerome John Van De Kamp Jun 1928

A Study Of The Temperature Behavior Of Various Liquids When Subjected To Pressures Ranging Between One And One Hundred Pounds Absolute, Jerome John Van De Kamp

Bachelors’ Theses

This thesis is submitted as a partial requirement for the degree of bachelor of science. The problem is one which dates back as far as the science which claims its authorship. It is a problem of which very little is known and one is justified in calling this old problem a youthful one, youthful, of course, in the sense that it is immature and as yet undeveloped. The problem by the very fact that it is in its infancy makes it one of Infinite length. It is a problem which has no greater practical application. Its ultimate value extends into …


The Monadnock Volume 2, Number 2, March 1928, Clark University Geographical Society Mar 1928

The Monadnock Volume 2, Number 2, March 1928, Clark University Geographical Society

The Monadnock (Clark Geographical Society)

Volume 2, Issue 2 of The Monadnock. The Monadnock was the alumni magazine of the Clark University Geographical Society (1927-1985) (2014-present).


Balanced Needle Valves For Echo, Gibson, And Coolidge Dams, U.S. Department Of The Interior, Bureau Of Reclamation Jan 1928

Balanced Needle Valves For Echo, Gibson, And Coolidge Dams, U.S. Department Of The Interior, Bureau Of Reclamation

All U.S. Government Documents (Utah Regional Depository)

Invitations for bids, schedule specifications, and drawings for balanced needle valves for Echo, Gibson, and Coolidge Dams.


Test 149: Cletrac Model 40 40-55, Nebraska Tractor Test Lab Jan 1928

Test 149: Cletrac Model 40 40-55, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 152: Twin City Model Ft 21-32, Nebraska Tractor Test Lab Jan 1928

Test 152: Twin City Model Ft 21-32, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Advertising Brochure: The Great Minneapolis Line, Nebraska Tractor Test Lab Jan 1928

Advertising Brochure: The Great Minneapolis Line, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 154: Rumely Do-All, Nebraska Tractor Test Lab Jan 1928

Test 154: Rumely Do-All, Nebraska Tractor Test Lab

Nebraska Tractor Tests

No abstract provided.


Test 148: Lauson S12 20-35, Nebraska Tractor Test Lab Jan 1928

Test 148: Lauson S12 20-35, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 151: Allis Chalmers 20-35, Nebraska Tractor Test Lab Jan 1928

Test 151: Allis Chalmers 20-35, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 150: Caterpiller Model 20 20-25, Nebraska Tractor Test Lab Jan 1928

Test 150: Caterpiller Model 20 20-25, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Experimental And Observational Geometry, Albert D. Field Jan 1928

Experimental And Observational Geometry, Albert D. Field

University of the Pacific Theses and Dissertations

Geometry has the distinction of being one of the oldest subjects given in the high-school.

Its subject-matter was formulated and organized by the Greeks into a fine system of thought before the time of Christ. Since leaving the hands of the Greeks, geometry has received only a few minor changes, and these largely in recent years.

Heretofore, the study of geometry has been made almost entirely dependent upon memory and reasoning. Geometricians have been slow in adopting the laboratory and observational methods.

This thesis has been written to encourage the student in his work of observing geometrical forms, and in …


Test 153: John Deere Gp 10-20, Nebraska Tractor Test Lab Jan 1928

Test 153: John Deere Gp 10-20, Nebraska Tractor Test Lab

Nebraska Tractor Tests

EXPLANATION OF TEST REPORT: John Deere GP 10-20

TEST A: The manufacturer's representative operates the tractor for a minimum of 12 hours using light to heavy drawbar loads in each gear.

This serves as a period for limber up, general observation and adjustments. Adjustments that are permissible include valve tappet clearance, breaker ,point gap, spark plug gaps, clutch and others of a similar nature. No new parts or accessories can be installed without having mention made of it in the report. No data' are recorded during this preliminary run except the time that the engine is operated.

BELT HORSEPOWER TESTS …


Test 154: Advance-Rumely "Do All", Nebraska Tractor Test Lab Jan 1928

Test 154: Advance-Rumely "Do All", Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Test 153: John Deere "General Purpose" 10-20, Nebraska Tractor Test Lab Jan 1928

Test 153: John Deere "General Purpose" 10-20, Nebraska Tractor Test Lab

Nebraska Tractor Tests

All tractors tested at the Nebraska Tractor Test Laboratory were certified by their manufacturers as being stock model machines, conforming to specifications filed with the application for test. No special or high-test fuels were used except as recommended by the manufacturer as necessary.

All results within the official tractor test report were actually attained in tests and are without correction or allowances for friction, temperature, altitude, etc. The results were initially accomplished with the tractor in charge of skilled operators employed by the University.

Unless otherwise noted, each tractor was apparently in good condition at the end of the testing …


Heavy Minerals In The Roubidoux And Other Sandstones Of The Ozark Region (Mo.), Cletus Daniel Cordry Jan 1928

Heavy Minerals In The Roubidoux And Other Sandstones Of The Ozark Region (Mo.), Cletus Daniel Cordry

Masters Theses

"In this study an attempt has been made to determine the usefulness of heavy minerals for correlation of formations over a limited area, in the heart of the Ozark uplift in southeast Missouri. The Roubidoux formation, already definitely correlated by other means, has been rather systematically sampled throughout the area, and the heavy minerals determined to ascertain their dependability for correlation purposes. Several samples from other horizons have been studied for comparison with the Roubidoux. Also, within the area studied there are numerous isolated patches of sandstone, the horizons of which have not been definitely determined. Samples from a few …


A Means Of Making A Segregate Preparatory To Chemical Analysis Of The Sulphide Minerals In A Low-Grade Dolomitic Ore-Pulp Containing Lead, Zinc, And Copper, Julius Bruce Clemmer Jan 1928

A Means Of Making A Segregate Preparatory To Chemical Analysis Of The Sulphide Minerals In A Low-Grade Dolomitic Ore-Pulp Containing Lead, Zinc, And Copper, Julius Bruce Clemmer

Masters Theses

"The object of this investigation was to find a means of obtaining from a low-grade dolomitic ore pulp a segregate of the sulphide minerals of lead, zinc, and copper preliminary to chemical analysis so that the chemist's error of 0.03 per cent would be divided by the ratio of the segregate to the entire pulp, and hence be reduced. Two methods of obtaining the segregate were investigated: (1) By float-and-sink tests, and (2) by selective dissolution of the dolomite, which is the main gangue constituent of the ore"--Object of Investigation, page 3.