G87-846 Electrical Systems For Agricultural Buildings (Checklist), Gerald R. Bodman, Laverne E. Stetson, Jack L. Schinstock Jan 1987

G87-846 Electrical Systems For Agricultural Buildings (Checklist), Gerald R. Bodman, Laverne E. Stetson, Jack L. Schinstock

University of Nebraska-Lincoln Extension: Historical Materials

This NebGuide is a checklist to help in evaluating both existing and new electrical installations for agricultural buildings.

Good electrical system design and installation is required to assure a safe, efficient system. Good practices and appropriate equipment are essential.


Scanning Electron Microscope Evaluation Of Drilling Damage And Acid Treatment Using Uncoated Core, D. R. Rothbard, R. A. Skopec, C. J. Bajsarowicz, T. H. Fate Dec 1986

Scanning Electron Microscope Evaluation Of Drilling Damage And Acid Treatment Using Uncoated Core, D. R. Rothbard, R. A. Skopec, C. J. Bajsarowicz, T. H. Fate

Scanning Microscopy

A novel SEM technique allows the observation of the same pore on a core face after each step in a series of dynamic flow tests. It requires no conductive coating and facilitates core flow using a one inch (25.4 mm) diameter plug. Three separate studies were undertaken in which the procedure was used to observe the effects of drilling mud invasion, waterflooding, and matrix acidization on individual grains and pores. In the drilling mud study it was found that 2% HF removed most of the siderite weighted mud, but that mud residue and etching of the framework grains resulted in …


Scanning Electron Microscopy Of Microcorrosion Casts: Applications In Ophthalmologic Research, Peter C. Burger, David B. Chandler, Andrzeji W. Fryczkowski, Gordon K. Klintworth Nov 1986

Scanning Electron Microscopy Of Microcorrosion Casts: Applications In Ophthalmologic Research, Peter C. Burger, David B. Chandler, Andrzeji W. Fryczkowski, Gordon K. Klintworth

Scanning Microscopy

In light of the complicated nature of the ocular vasculature, it has been difficult to define the normal ocular anatomy by reference to two-dimensional tissue sections. Since it provides three-dimensional replicas, scanning electron microscopy (SEM) of vascular corrosion casts has therefore been an invaluable addition to the study of ocular vasculature. This technique also often permits identification of a normal vessel's arterial, venous, or capillary nature by its surface features. In addition, this technique is finding increased use in defining anatomical features of human vascular disease and is especially well suited for the study of experimental neovascularization as it relates …


Materials Characterization Using The Backscattered Electron Signal In Scanning Electron Microscopy, V. N. E. Robinson Oct 1986

Materials Characterization Using The Backscattered Electron Signal In Scanning Electron Microscopy, V. N. E. Robinson

Scanning Microscopy

The backscattered electron signal in scanning electron microscopy is sensitive to changes in the atomic number of the specimen. This atomic number information can be measured by calibrating the output of a backscattered electron detector from two known materials. The atomic number of an unknown sample can then be determined by measuring the backscattered electron signal from the unknown sample.

Knowing the atomic number factor of an unknown sample and the heavy elements (Z > 10 as determined from X-ray analysis), the existence of light elements can be detected. From a knowledge of the sample and valence information, the composition of …


Vasospastic Phenomena On The Luminal Replica Of Rat Brain Vessels, Enrico D. F. Motti, Hans-Georg Imhof, Jesus Martinez Garza, Gazi M. Yasargil Oct 1986

Vasospastic Phenomena On The Luminal Replica Of Rat Brain Vessels, Enrico D. F. Motti, Hans-Georg Imhof, Jesus Martinez Garza, Gazi M. Yasargil

Scanning Microscopy

Strikingly localized ring-like constrictions (other than sphincters, cushions and offshoot furrows) have appeared on the casted vessels of some of our preparations. Morphology of the phenomena reveals diverse degree of active contraction of the vessel wall, ranging from corrugation of the luminal surface to near severance of the acrylic cast. Distribution of the vasospastic phenomena reveals as particularly affected the arteries in the diameter range between 25 and 75 μm, that belong either to intra-arterial anastomoses between the branches of each of the three major cerebral arteries or to their terminal junctions in the border zones (inter-arterial anastomoses). Among the …


A New Surface Analytical Technique With Ion And Laser Beams, Christopher H. Becker Oct 1986

A New Surface Analytical Technique With Ion And Laser Beams, Christopher H. Becker

Scanning Electron Microscopy

This paper reviews recent results and developments, while presenting some new information, regarding the development of a novel surface analytical technique that uses nonresonant multiphoton ionization (MPI) of neutral atoms and molecules sputtered by an ion beam, or desorbed by an electron or second laser beam or by thermal means. In this method, called surface analysis by laser ionization (SALI), the nonresonant MPI, or "laser ionization," is coupled with state-of-the-art time-of-flight mass spectrometry to provide extremely sensitive, general, and readily quantifiable surface analysis. A discussion also describes the favorable prospects for implementation of SALI with submicron dimension liquid metal ion …


Some Thoughts About The Conservation Of Scanning Electron Microscopic Preparations Of Diatoms In A Museum Repository, J. J. Lee, C. W. Reimer, R. Mahoney Sep 1986

Some Thoughts About The Conservation Of Scanning Electron Microscopic Preparations Of Diatoms In A Museum Repository, J. J. Lee, C. W. Reimer, R. Mahoney

Scanning Electron Microscopy

The Scanning electron microscope (SEM) is now an indispensable tool for the study and the description of diatoms. Many new species have been described from SEM preparations and problems now arise with the preservation of designated types and other comparative material. Moisture contributes to the deterioration of diatom stubs. Special care must be taken to store stubs in vacuum desiccators in order to keep heavy metal coatings from peeling from the siliceous surfaces of diatoms. One alternative is to mount the designated type on a coverglass so that it can be inverted, mounted in Hyrax and preserved indefinitely for light …


The Microvascular Architecture Of The Vestibule And The Endolymphatic Duct And Sac Of The Rat In Vascular Corrosion Casts, Takuya Ohmichi, Ryuske Saito, Kiyoshi Matsubara, Kazutaka Terazawa, Shuji Tasaka, Yoshio Ogura Sep 1986

The Microvascular Architecture Of The Vestibule And The Endolymphatic Duct And Sac Of The Rat In Vascular Corrosion Casts, Takuya Ohmichi, Ryuske Saito, Kiyoshi Matsubara, Kazutaka Terazawa, Shuji Tasaka, Yoshio Ogura

Scanning Electron Microscopy

The blood vessels of the vestibule and the endolymphatic duct and sac (ES) of the rat were reproduced with methacrylate casting medium and observed under a scanning electron microscope.

Dense capillary networks of the macula utriculi and the macula sacculi were observed. The collecting venules from the vestibule emptied into the vein of the vestibular aqueduct (VVAQ). The plexus of the vessels in the ES was triangular in shape and had anastomoses with vessels of the bone and dura and drained into the VVAQ. The posterior meningeal artery (PMA) gave off two branches to the ES. These findings supported the …


Scanning Electron Microscopy Of Thebesian Ostia (Microdissection By Ultrasonication: Enzymatic Digestion), F. A. Rosinia, F. N. Low Sep 1986

Scanning Electron Microscopy Of Thebesian Ostia (Microdissection By Ultrasonication: Enzymatic Digestion), F. A. Rosinia, F. N. Low

Scanning Electron Microscopy

Thebesian vasculature provides for communication between the coronary system and the chambers of the heart. Anatomic, embryologic, physiologic, and therapeutic investigations have involved this component of cardiac anatomy from the early 18th century to the present time. The scanning electron microscope (SEM) now affords an innovative approach to the study of the ostia of these veins as they open into the chambers of the heart. The surface of the intact endocardium is continuous, whether it is treated with boric acid or not, as long as it remains intact. Enzymatic microdissection of tissues with trypsin, hyaluronidase and pronase, followed by similar …


The Capillary Bed In The Choroid Plexus Of The Lateral Ventricles: A Study Of Luminal Casts, Enrico D. F. Motti, Hans-Georg Imhof, Robert C. Janzer, Klaus Marquardt, Gazi M. Yasargil Sep 1986

The Capillary Bed In The Choroid Plexus Of The Lateral Ventricles: A Study Of Luminal Casts, Enrico D. F. Motti, Hans-Georg Imhof, Robert C. Janzer, Klaus Marquardt, Gazi M. Yasargil

Scanning Electron Microscopy

Micro-angioarchitecture of the choroid plexus of the lateral ventricles is investigated in microcorrosion casts of animal and human preparations studied with the scanning electron microscope. The capillary bed in the diverse regions of the tissue belongs to one of three patterns: (1)-a network of capillary meshes that envelop the larger arteries and veins predominates in the central segment. (2)-in the villous regions a "leaf-like" organization of sinusoids is found together with (3)-fronds of "glomerular" formations. "Glomeruli" are formed when arterial afferents and venous efferents converge in a quasi hilar structure before branching in arterio-venous loops. Nodular thickenings are observed on …


The Gill Arch Of The Striped Bass, Morone Saxatilis. Ii. Microvasculature Studied With Vascular Corrosion Casting And Scanning Electron Microscopy, Judy A. C. King, F. E. Hossler Sep 1986

The Gill Arch Of The Striped Bass, Morone Saxatilis. Ii. Microvasculature Studied With Vascular Corrosion Casting And Scanning Electron Microscopy, Judy A. C. King, F. E. Hossler

Scanning Electron Microscopy

The gill vasculature of euryhaline striped bass, Morone saxatilis, was examined by scanning electron microscopy of corrosion casts prepared by injecting resin (either Mercox/Sevriton or L.R. White) into the ventral aorta. The vasculature of the striped bass gill appears to be similar to that of other euryhaline species. The striped bass gill has three major vascular systems: (1) a respiratory system, (2) an arterio-venous system, and (3) a nutritive system. In the respiratory system, blood from the afferent branchial artery flows to each filament via an afferent filamental artery, and from there to the highly vascularized respiratory lamellae. Lamellar …


Anatomy And Morphometry Of Myocardial Capillaries Studied With Vascular Corrosion Casting And Scanning Electron Microscopy: A Method For Rat Heart, F. E. Hossler, J. E. Douglas, L. E. Douglas Aug 1986

Anatomy And Morphometry Of Myocardial Capillaries Studied With Vascular Corrosion Casting And Scanning Electron Microscopy: A Method For Rat Heart, F. E. Hossler, J. E. Douglas, L. E. Douglas

Scanning Electron Microscopy

The present paper describes a procedure for preparing vascular corrosion casts of rat myocardial microvasculature. Essential components of the procedure include: partial "self clearing" of the heart in vitro; cardiac arrest by infusion of KCl; retrograde aortic root infusion of Mercox-Sevriton casting resin; KOH digestion of ventricular tissue; and desiccation and mounting of casts for scanning electron microscopy. About 50% of rats yielded complete casts. Vasculature closely paralleled muscle fiber orientation. Capillary beds characteristically exhibited branching, many intercapillary cross bridges, and occasional coil-ing. Average capillary cast diameter (5.6 μm) and intercapillary distance (15 μm) are comparable to results from in …


Microcorrosion Casts In The Microcirculation Of Skeletal Muscle, L. Pannarale, E. Gaudio, G. Marinozzi Jul 1986

Microcorrosion Casts In The Microcirculation Of Skeletal Muscle, L. Pannarale, E. Gaudio, G. Marinozzi

Scanning Electron Microscopy

The authors review the contribution of microcorrosion cast studies towards clarifying the structure of skeletal muscle microcirculation.

Former studies performed on naturally contracted muscles show the presence of a primary and a secondary arterial network and a capillary network. At the level of the capillary network pericyte imprints are present. Muscles characterized by different types of metabolism show different features of the capillary pattern. Other authors have affirmed that the extended muscle is characterized by long and straight capillaries, while the contracted one features clusters of vessels all around a muscle fiber.

The authors have made the present observations in …


The Three-Dimensional Microstructure Of The Liver A Review By Scanning Electron Microscopy, G. Macchiarelli, P. M. Motta Jul 1986

The Three-Dimensional Microstructure Of The Liver A Review By Scanning Electron Microscopy, G. Macchiarelli, P. M. Motta

Scanning Electron Microscopy

The improvement in scanning electron microscopy (SEM) techniques has permitted us to describe the microstructure of the liver. By SEM, the liver peritoneal surface is composed of flat mesothelial cells possessing microvilli and cilia. Hepatic sinusoids connect the portal vessels with the terminal branches of the hepatic vein (central veins). Endothelial cells of the portal space arteries are elongated and arranged longitudinally, while those of the central and portal veins are polygonal and flattened, possessing microvilli. The sinusoidal endothelial cells show both small fenestrations (sieve plates), up to 200 nm in diameter, and large ones, up to 1 𝝁m. Within …


Using Electron Spectroscopy For Chemical Analysis (Esca) In Failure Analysis: Some Recent Developments, M. A. Kelly, L. H. Scharpen, R. D. Cormia Jul 1986

Using Electron Spectroscopy For Chemical Analysis (Esca) In Failure Analysis: Some Recent Developments, M. A. Kelly, L. H. Scharpen, R. D. Cormia

Scanning Electron Microscopy

Electron spectroscopy for chemical analysis (ESCA) is receiving increased attention as a surface-sensitive failure analysis technique because of several recent developments. These are: first - substantially improved spatial resolution, allowing a much broader range of problems to be studied; second - new ways to apply analytical results to practical problems, resulting from better technical understanding of ESCA and better data reduction techniques; and third - the development of sample handling systems which can handle large, outgassing samples, making ESCA a relatively non-destructive technique.

In this paper we consider ESCA's niche as a surface analysis tool, and discuss the impact of …


Microcorrosion Casting Of The Human Respiratory Acinus, S. A. Dilly Jul 1986

Microcorrosion Casting Of The Human Respiratory Acinus, S. A. Dilly

Scanning Electron Microscopy

Microcorrosion casts demonstrating the respiratory acini of human lungs were produced using Tensol Cement No. 70 (a methyl methacrylate mixture). Lung casts were made from foetuses of 19 weeks' gestation to term, a child of 5 years and two adults. Tensol Cement No. 70 was found to infuse the most peripheral airspaces without tissue penetration and could be airdried. Attempts using Batson's medium were hampered by permeation of the airway walls and inability to withstand airdrying. Despite the use of autopsy material, good cell impressions were seen.

At 19 weeks' gestation, the respiratory acinus is simple with only two or …


Applications Of X-Ray Microanalysis To The Study And Conservation Of Ancient Glasses, S. Hreglich, M. Verita Jun 1986

Applications Of X-Ray Microanalysis To The Study And Conservation Of Ancient Glasses, S. Hreglich, M. Verita

Scanning Electron Microscopy

X-ray microanalysis can be successfully applied to the study of the chemical composition and weathering processes of ancient glass. The problems concerned with this kind of application are considered. A verification is conducted of the accuracy and sensitivity of this technique, which are sufficient to obtain useful information on technologies and raw materials used and consequently on the origin and dating of ancient glasses.

This analytical method also discloses meaningful data for the optimization of restoration and the choice of appropriate conservation operations.


Intrauterine Device (Iud) Associated Pathology: A Review Of Pathogenic Mechanisms, Waldemar A. Schmidt, Karmen L. Schmidt Jun 1986

Intrauterine Device (Iud) Associated Pathology: A Review Of Pathogenic Mechanisms, Waldemar A. Schmidt, Karmen L. Schmidt

Scanning Electron Microscopy

This paper summarizes our studies of IUD-related disease with those previously published by others. Our data are based upon 51 IUDs and 42 index cases of IUD-related disease demonstrating specific processes. Gross, dissecting microscope, scanning electron microscope and X-ray microanalysis examinations were made of selected IUDs and associated tissues. Tissue associated with the IUDs revealed inflammation in 59.4%, calcific material in 6.3% and no abnormality in 34.4%. JUD-associated tissue responses were accompanied by changes of the IUD; these changes involved deposition of substances upon the IUD surface and degradation of the JUD itself. Disintegration of the IUD, its string or …


Scanning Electron Microscopy Of The Microvascular System In The Inner Ear, Yoshiaki Nakai, Haruhiko Masutani, Hiromasa Cho Jun 1986

Scanning Electron Microscopy Of The Microvascular System In The Inner Ear, Yoshiaki Nakai, Haruhiko Masutani, Hiromasa Cho

Scanning Electron Microscopy

In the present work, vessels casts in the inner ear of the rat and guinea pig, prepared by casting method using Mercox resin, were subjected to scanning electron microscopic examination and following results were obtained: 1) In adult guinea pig, numerous capillary nets were found in the following parts: stria vascularis, spiral ligament, spiral prominence, Corti's organ, spiral ganglion, plexus cochlearis, semicircular ampulla, saccule, utricle, and endolymphatic sac. These were consistent with functionally and morophologically important areas in the inner ear. 2) In the central side of the area with capillary nets, arterioles were found to run throughout, like a …


Ultrasonic Microdissection Of Immature Intermediate Human Placental Villi As Studied By Scanning Electron Microscopy, Gregory J. Highison, F. Donald Tibbitts Jun 1986

Ultrasonic Microdissection Of Immature Intermediate Human Placental Villi As Studied By Scanning Electron Microscopy, Gregory J. Highison, F. Donald Tibbitts

Scanning Electron Microscopy

The human placenta during the first 20 weeks of gestation undergoes rapid and extensive morphological changes. Near the end of this period, the most predominant type of villus present is the immature intermediate placental villus. In order to visualize this complex structure with scanning electron microscopy (SEM), we have developed a microdissection technique to expose tissue components of the placental villus while retaining its normal histological architecture. Placental villi were initially fixed in Karnovsky's fixative, buffered formalin, or 2% osmium tetroxide solution prior to exposure to connective tissue enzymes or detergents alone or in combination. Samples were dehydrated through 100% …


The Characteristic Structural Features Of The Blood Vessels Of The Lewis Lung Carcinoma (A Light Microscopic And Scanning Electron Microscopic Study), T. W. Grunt, A. Lametschwandtner, K. Karrer Jun 1986

The Characteristic Structural Features Of The Blood Vessels Of The Lewis Lung Carcinoma (A Light Microscopic And Scanning Electron Microscopic Study), T. W. Grunt, A. Lametschwandtner, K. Karrer

Scanning Electron Microscopy

Vascular corrosion casts of Lewis lung carcinomas (LLC) grown subcutaneously in C57BL/6-mice are correlated with histological sections and with tumor tissue prepared for scanning electron microscopy (SEM). By making low, medium and high pressure cast preparations we studied the influence of perfusion and injection pressure on the resulting cast sample.

Three types of vascular proliferations are distinguishable in LLC: 1) Small globular outgrowths on sinusoidal dilated tumor capillaries, caused by proliferation of their endothelial cells. 2) New sprouts on surrounding host vessels, invading the small, still avascular implant. 3) Superficially located, centrifugally running sprouts in peripheral regions of large tumors. …


The Angioarchitecture Of The Lewis Lung Carcinoma In Laboratory Mice (A Light Microscopic And Scanning Electron Microscopic Study), T. W. Grunt, A. Lametschwandtner, K. Karrer, O. Staindl Jun 1986

The Angioarchitecture Of The Lewis Lung Carcinoma In Laboratory Mice (A Light Microscopic And Scanning Electron Microscopic Study), T. W. Grunt, A. Lametschwandtner, K. Karrer, O. Staindl

Scanning Electron Microscopy

53 Lewis lung carcinomas implanted subcutaneously into C57BL/6-mice were examined. The animals were killed at various stages of tumor growth (TG) and prepared for histology and for scanning electron microscopy (critical-point-dried tissue; vascular corrosion casts). Prior to casting animals were rinsed using different perfusion pressures. Casting was done by manual injection of the resin, whereby different influx-rates were applied resulting in low, medium and high pressure preparations.

We discern 3 phases of tumor angiogenesis (TA) occurring during 4 stages of TG among which vasodilation establishes the first reaction of the host vascular system to a growing tumor implant. During this …


The Identification And Characterization Of Metal Wrappings In Historic Textiles Using Microscopy And Energy Dispersive X-Ray Spectrometry: Problems Associated With Identification And Characterization, N. Indictor, R. J. Koestler May 1986

The Identification And Characterization Of Metal Wrappings In Historic Textiles Using Microscopy And Energy Dispersive X-Ray Spectrometry: Problems Associated With Identification And Characterization, N. Indictor, R. J. Koestler

Scanning Electron Microscopy

Scanning electron microscopy-energy dispersive x-ray spectrometry (SEM-EDS) has been employed for the description of metal wrapped yarns. Although considerable detail is obtainable as microphotographs, and elemental analysis is obtained with ease, caution should be exercised in interpreting results. Several unravelled samples should be examined; light microscopy should be employed prior to SEM-EDS analysis. Examination of eight specimens (six from the textile collection of the Metropolitan Museum of Art, New York; two from private collections) is described. The samples were Chinese (5), German (1), Spanish (1), Turkish (1). Difficulties encountered in describing this set of samples are enumerated.


Corrosion Cast Technique Applied In Lymphatic Pathways, A. Castenholz May 1986

Corrosion Cast Technique Applied In Lymphatic Pathways, A. Castenholz

Scanning Electron Microscopy

The paper deals with methods and results of the microcorrosion cast technique in lymph angiology. For the representation of the special organization of the lymph vascular system including the initial vascular structures, intranodal pathways, bigger collectors, and lymph trunks, the application of various injection techniques is necessary. The interstitial injection of Mercox proves to be suitable to show the initial lymphatics and prelymphatic spaces. Similarly, the intranodal injection makes visible the system of the lymph sinuses and the spaces of the reticular tissue in this organ. Casts of bigger collecting vessels, lymph trunks, and thoracic duct can be obtained by …


Functional Aspects Of Renal Glomeruli Based On Scanning Electron Microscopy Of Corrosion Casts, With Special Emphasis On Reptiles And Birds, H. Ditrich, H. Splechtna Apr 1986

Functional Aspects Of Renal Glomeruli Based On Scanning Electron Microscopy Of Corrosion Casts, With Special Emphasis On Reptiles And Birds, H. Ditrich, H. Splechtna

Scanning Electron Microscopy

The glomerular complexity of several species of birds and reptiles is investigated in this study by scanning electron microscopy of vascular corrosion casts. Comparing these results with those of a freshwater teleost and a mammalian species, a trend towards small, simple glomeruli of the avian type, beginning with large, well vascularized glomeruli resembling the type found in fish, can be observed in reptiles.

A close correlation between glomerular size and habitat can be established comparing related species having a similar physiological mode of renal function.

Entirely different from this sauropsidian evolutionary line of development is the highly complex, large differentiation …


Technical Parameters Of Plastics (Mercox Cl-2b And Various Methylmethacrylates) Used In Scanning Electron Microscopy Of Vascular Corrosion Casts, T. Weiger, A. Lametschwandtner, P. Stockmayer Apr 1986

Technical Parameters Of Plastics (Mercox Cl-2b And Various Methylmethacrylates) Used In Scanning Electron Microscopy Of Vascular Corrosion Casts, T. Weiger, A. Lametschwandtner, P. Stockmayer

Scanning Electron Microscopy

The most frequently used resins for vascular corrosion casting Mercox Cl-2B, Mercox Cl-2B diluted with methylmethacrylate (MMA) monomer and various self prepared MMA and hydroxyproyl-methacrylate mixtures were tested with regard to their thermostability, shrinkage, viscosity and replication quality. It was found that tempering of the plastics improves their thermostability with the exception of Mercox Cl-2B and that shrinkage depends on the amount of monomers a resin contains. In detail; Mercox Cl-2B has the lowest shrinkage (8.018%) whereas a hydroxypropyl-methacrylate mixture possessed the highest (20.408%). But, on the other hand, viscosity decreases with the quantity of monomers. All resins tested were …


Scanning Electron Microscopic Studies On Microvascular Architecture Of Human Coronary Vessels By Corrosion Casts: Normal And Focal Necrosis, T. Ono, Y. Shimohara, K. Okada, S. Irino Apr 1986

Scanning Electron Microscopic Studies On Microvascular Architecture Of Human Coronary Vessels By Corrosion Casts: Normal And Focal Necrosis, T. Ono, Y. Shimohara, K. Okada, S. Irino

Scanning Electron Microscopy

Microvascular architecture of the normal human heart and myocardial focal necrosis were studied by scanning electron microscopy of corrosion casts. Casts macroscopically identical in form to the left ventricular posterior wall were prepared.

The following results were obtained in the normal human heart. (I) Most of the arterioles communicated with capillary plexuses smoothly and straight forwardly in the left ventricular posterior free wall. (2) Arterioles which branched from the arteries ran in various directions and continued into capillaries either at right angles or obliquely in the trabeculae carneae. (3) capillaries running parallel with the cardiac muscle fibers ran in different …


The Effects Of Alum At Different Ph Levels On Asa Sizing, James A. Farrand Apr 1986

The Effects Of Alum At Different Ph Levels On Asa Sizing, James A. Farrand

Paper Engineering Senior Theses

Alkenyl succinic anhydride (ASA) is a cellulose reactive size used in neutral to alkaline sizing. ASA is emulsified in cationic starch to help retain the ASA on the fiber and to protect the ASA from hydrolysis. The stability of the ASA emulsion is largely dependent upon temperature, pH, and shear.

While one of the advantages of alkaline papermaking is the elimination of aluminium from the process water, the addition of small amounts of alum has proven beneficial to some mills running ASA size. The advantages claimed by using alum are: improved sizing, improved retention, and improved runnability.

The aluminum species …


A Review Of Modern Characterization Methods For Semiconductor Materials, T. J. Shaffner Mar 1986

A Review Of Modern Characterization Methods For Semiconductor Materials, T. J. Shaffner

Scanning Electron Microscopy

The manufacture of solid state devices in the microelectronics industry involves crystal growth, slice preparation, diffusion and implantation, oxide and metal deposition, patterning and etching, probe testing and packaging of completed devices. This simplified process flow is adopted in an overview to briefly outline some established as well as newly developed techniques of materials characterization. The complexity of semiconductor processing has imposed greater stringency criteria which have resulted in the revitalization of old methods as well as the development of new techniques capable of extreme sensitivity and spatial resolution.

Examples given for trace impurity and dopant detection include neutron activation …


Proceedings From The 23rd Annual Marschall Invitational, Various Authors Jan 1986

Proceedings From The 23rd Annual Marschall Invitational, Various Authors

Cheese Industry Conference

No abstract provided.