Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- Utah State University (263)
- University of Nebraska - Lincoln (204)
- Department of Primary Industries and Regional Development, Western Australia (136)
- Western Michigan University (76)
- University of Kentucky (57)
-
- South Dakota State University (43)
- TÜBİTAK (42)
- University of Arkansas, Fayetteville (42)
- University of South Florida (41)
- California Polytechnic State University, San Luis Obispo (38)
- Louisiana State University (38)
- Nova Southeastern University (34)
- Faculty of Engineering, Mansoura University (29)
- Israel Antiquities Authority (25)
- Colby College (24)
- Universiti Brunei Darussalam (23)
- Old Dominion University (21)
- WellBeing International (21)
- Brigham Young University (20)
- Karbala International Journal of Modern Science (20)
- Clemson University (19)
- Technological University Dublin (19)
- University of South Carolina (18)
- National Taiwan Ocean University (16)
- The Texas Medical Center Library (16)
- University of Dar es Salaam (16)
- University of Nevada, Las Vegas (15)
- Changsha University of Science and Technology (14)
- Michigan Technological University (14)
- Claremont Colleges (12)
- Keyword
-
- Western Australia (92)
- Scanning electron microscopy (69)
- Agriculture (32)
- Water (30)
- Corrosion casting (27)
-
- Biofilm (26)
- Water quality (26)
- Agricultural newspapers (22)
- American newspapers (22)
- Central Maine (22)
- Maine history (22)
- Popular literature (22)
- 19th century newspapers (21)
- Pollution (20)
- Publications (20)
- Scanning Electron Microscopy (19)
- Extension publications (18)
- Irrigation (18)
- Drinking water (17)
- Groundwater (16)
- Biological sciences (15)
- Blood vessels (15)
- Microcirculation (15)
- Natural resources (15)
- Nebraska Cooperative Extension (15)
- Storage (15)
- Cooperative Extension (14)
- Corrosion (14)
- Engineering (14)
- Physical Sciences (14)
- Publication Year
- Publication
-
- Scanning Microscopy (134)
- Journal of the Department of Agriculture, Western Australia, Series 4 (90)
- Paper Engineering Senior Theses (58)
- Theses and Dissertations (57)
- University of Nebraska-Lincoln Extension: Historical Materials (55)
-
- Electronic Theses and Dissertations (39)
- Scanning Electron Microscopy (34)
- Mansoura Engineering Journal (29)
- NEBLINE Newsletter Archive from Nebraska Extension in Lancaster County (29)
- Graduate Theses and Dissertations (25)
- 'Atiqot (24)
- Masters Theses (24)
- ASEAN Journal on Science and Technology for Development (23)
- All Current Publications (21)
- All Graduate Theses and Dissertations, Spring 1920 to Summer 2023 (21)
- Master's Theses (21)
- Karbala International Journal of Modern Science (20)
- Dissertations (18)
- Faculty Publications (17)
- LSU Master's Theses (17)
- Journal of Marine Science and Technology–Taiwan (16)
- Faculty, Staff and Student Publications (15)
- Marine Science Faculty Publications (15)
- Tanzania Journal of Science (15)
- Turkish Journal of Agriculture and Forestry (15)
- Food and Machinery (14)
- Honors Theses (14)
- Nebraska Agricultural Experiment Station: Historical Circulars (14)
- Turkish Journal of Veterinary & Animal Sciences (14)
- International Journal of Speleology (13)
- Publication Type
- File Type
Articles 1531 - 1560 of 1919
Full-Text Articles in Entire DC Network
Surface Analysis Of Tarnished Dental Alloys, H. J. Mueller, J. W. Lenke, M. S. Bapna
Surface Analysis Of Tarnished Dental Alloys, H. J. Mueller, J. W. Lenke, M. S. Bapna
Scanning Microscopy
Six crown and bridge alloys ranging in nobility between 25-63 wt % (18-45 at %) were analyzed by optical microscopy, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and secondary ion mass spectroscopy (SIMS), as well as by L*a*b* colorimetry before and after in vitro tarnishing in artificial saliva with and without additions of 0.00016, 0.016, and 1.6 % Na2S with a rotating wheel apparatus. All alloys except the lowest of 18 at % changed colors to about the same degree after 72 h of tarnishing. All alloys decreased in L*, while increased in both a* and b*, …
Application Of Scanning Electron Microscopy And X-Ray Microanalysis To Investigate Corrosion Problems In Plain Tinplate Food Cans And Examine Glass And Glass-Like Particles Found In Canned Food, James E. Charbonneau
Application Of Scanning Electron Microscopy And X-Ray Microanalysis To Investigate Corrosion Problems In Plain Tinplate Food Cans And Examine Glass And Glass-Like Particles Found In Canned Food, James E. Charbonneau
Food Structure
Scanning Electron Microscopy (SEM) and X-ray Microanalysis (EDS) have been used to investigate product container interaction problems in plain tinplate metal food containers and to examine glass and glass-like particles that were found in canned food.
Through the use of SEM-EDS, it was determined that: sulfate containing particles from the cannery cooling water reacted with exposed iron or tin-iron alloy on the tinplate surface causing an external rusting problem; sulfur dioxide was responsible for a container discoloration and a pitting corrosion problem in canned fruit nectar; hydrogen sulfide produced from the SO2-tinplate reaction was the cause of an associated off-odor …
Ec88-422 Household Cleaning And Laundry Products: Which One For The Job?, Shirley Niemeyer, Kathleen Parrott, Rose Marie Tondl, Anna Marie White, Carol Thayer
Ec88-422 Household Cleaning And Laundry Products: Which One For The Job?, Shirley Niemeyer, Kathleen Parrott, Rose Marie Tondl, Anna Marie White, Carol Thayer
University of Nebraska-Lincoln Extension: Historical Materials
Nebraskans invest considerable resources in their homes and furnishings, and in clothing. We want these items to be attractive, functional, and to give us good service. A key to protecting our household investment is to give our homes, furnishings, and clothing appropriate care and maintenance. This circular discusses the various options in home cleaning and laundry products, methods and equipment, chemicals to remove soil and stains, and labor and time saving products to make the job of cleaning our homes easier.
The Role Of Scanning Electron Microscopy In Periodontal Research, A. Carrassi, S. Abati, G. Santarelli
The Role Of Scanning Electron Microscopy In Periodontal Research, A. Carrassi, S. Abati, G. Santarelli
Scanning Microscopy
During recent years a great amount of research has led to a better understanding of the etiology, pathogenesis and pattern of progression of periodontal diseases. Scanning electron microscopy (SEM) has contributed to this improvement, mainly with respect to histology of periodontal tissues, the description of the morphology and distribution of bacteria on the exposed root surface, analysis of the host-parasite interactions on the gingival pocket wall, and morphological evaluation of root treatment. This review deals with all these topics. Unusual types of SEM research are also described and discussed. Uncommon sample preparation techniques for SEM in periodontal research are described. …
Microvascular Casting Of The Lung: Vascular Lavage, Dean E. Schraufnagel, Aloisia Schmid
Microvascular Casting Of The Lung: Vascular Lavage, Dean E. Schraufnagel, Aloisia Schmid
Scanning Microscopy
Corrosion casting is an important tool for the study of microvascular structure, but unlike tissue preparation for light and electron microscopy, few controlled studies of the methods for preparation of microvascular casts for scanning electron microscopy have been reported. Most vascular casting begins with rinsing cells from the lumen of the blood vessels, but the necessity of this has not been shown. Because of a report of successful casting without rinsing and light microscopic evidence of edema with complete rinsing prior to casting, this preparation procedure was examined. Casts of lung vasculature that were thoroughly rinsed were compared to those …
Industrial Applications Of Auger Surface Analysis, R. E. Chase, G. S. Cole
Industrial Applications Of Auger Surface Analysis, R. E. Chase, G. S. Cole
Scanning Microscopy
Scanning Auger microscopy is distinguished by its unique combination of surface selectivity, high spatial resolution, ease of identifying elements and quantifying composition, and ability to distinguish between chemical states. This paper describes several applications of scanning Auger microscopy, emphasizing the range of industrial research activities:
1. Electronic Materials. Contamination in an integrated circuit processing facility was identified and procedures for its removal determined. Causes for the delamination of printed circuit board foils were identified. Superlattice films were characterized and the deposition process evaluated.
2. Tribology. Analysis of surfaces in lubricated sliding contact revealed the effects of con tact kinematics and …
Microanalytical And Micromorphological Investigations Of High Temperature Materials With And Without Protective Coatings, Volker Thien, W. Voss
Microanalytical And Micromorphological Investigations Of High Temperature Materials With And Without Protective Coatings, Volker Thien, W. Voss
Scanning Microscopy
The phenomenon "High Temperature Corrosion" (HTC) is described; three different types (pure oxidation, high temperature hot corrosion, low temperature hot corrosion) are defined. HTC is demonstrated taking gas turbine blades as an example. The results of laboratory HTC tests under defined conditions were compared with those of long time engine experience; the agreement is very satisfactory.
Metallurgical investigations with scanning electron microscopy and EDX-/WDX-analytical techniques gave explanations for the behaviour of protective coatings . The corrosion mechanism of a NiCrAlY-plasma spray coating is explained as consequence of Cr- and Al-oxidation. A special analytical technique - the "integral layer profile analysis" …
Microcorrosion Casting In Normal And Pathological Biliary Tree Morphology, E. Gaudio, L. Pannarale, F. Carpino, G. Marinozzi
Microcorrosion Casting In Normal And Pathological Biliary Tree Morphology, E. Gaudio, L. Pannarale, F. Carpino, G. Marinozzi
Scanning Microscopy
The organization of the intrahepatic biliary tree was studied in three dimensions by scanning electron microscopic (SEM) corrosion casts, in normal and cholestatic rat liver.
In the normal liver the observation revealed the features of the biliary passages from the bile canaliculi to the canaliculo-ductular junction, to the ductules and the bile ducts, confirming previous SEM observations.
In cholestatic liver, the modifications and the proliferation of bile ductules appear clearly.
Resin flow from canalicular to sinusoidal network was never observed.
The method was found to be very useful in the evaluation of the architecture of the intrahepatic biliary tree, under …
Proton-Induced X-Ray Emission Spectrometry In Archaeology, C. P. Swann, S. J. Fleming
Proton-Induced X-Ray Emission Spectrometry In Archaeology, C. P. Swann, S. J. Fleming
Scanning Microscopy
Proton-induced x-ray emission (PIXE) spectrometry is fast developing a reputation as a powerful analytical tool in the study of a range of ancient materials, including bronze, iron, gold, glass, faience, and smelting slag. PIXE data allows determination of the primary constituents which would indicate their recipe of production and determine their bulk physical properties (e.g., color of a glass, brittleness in a metal), and of a wide range of trace elements which may indicate the source of raw material s from which an artifact was constituted. Over the past seven years, PIXE spectrometry's primary advantage over other recognized methods now …
X-Ray Microanalysis Of Dentin: A Review, E. Hals, A. B. Tveit, B. Tøtdal
X-Ray Microanalysis Of Dentin: A Review, E. Hals, A. B. Tveit, B. Tøtdal
Scanning Microscopy
The aim of this review was to present a condensed summary of the literature on X-ray microanalysis of dentin, including both energy-dispersive (EDS) and wavelength-dispersive (WDS) analysis. Estimations of concentrations by XMA of dentin should be regarded as semiquantitative values. The Ca level in rat odontoblasts was elevated in the secreting end of the cell body. In predentin Ca accumulated at a concentration of 2% that of mineralized dentin. In coronal dentin the peritubular areas were hypermineralized (Ca, P, Mg). Primary caries lesions showed a decrease of Ca, P, Mg and Cl, and usually an increase of S and Zn. …
Cleaning Procedures For Small Dental Instruments Prior To Sterilization, K. S. Lester, P. Mitchell
Cleaning Procedures For Small Dental Instruments Prior To Sterilization, K. S. Lester, P. Mitchell
Scanning Microscopy
Observations were made in an institutional setting on the quality of cleaning of dental burs. Assessments were made by scanning electron microscopy of surface contamination and change to the surface quality of burs before and after use, and as a result of different cleaning procedures.
The most significant finding was the corrosive action on carbon steel burs of a phosphoric acid based cleaning solution in routine use at the time. We show by comparison the effectiveness and non-corrosive nature of an alternative detergent based on sulfamic acid, and propose a suitable cleaning routine.
Two other findings are presented: new burs …
Tandem Scanning Reflected Light Microscopy: Applications In Clinical Dental Research, Timothy F. Watson, Alan Boyde
Tandem Scanning Reflected Light Microscopy: Applications In Clinical Dental Research, Timothy F. Watson, Alan Boyde
Scanning Microscopy
The Tandem Scanning Reflected Light Microscope (TSRLM) enables the investigation of microscopic structures both at and deep to the surface of intact objects. The present paper reviews studies undertaken to determine whether the TSRLM would be usable and useful in the investigation of natural and restorative dental materials in vitro and in vivo.
It was found that the TSRLM could be used to study normal and diseased dental tissues and the new materials which are used to replace lost substance. More importantly, it could be used to characterize the interface between tooth and optically translucent materials in bulk samples, giving …
The Vascularization Of The Vertebral Column Of Rats, M. A. Konerding, M. Blank
The Vascularization Of The Vertebral Column Of Rats, M. A. Konerding, M. Blank
Scanning Microscopy
The intrinsic and extrinsic blood supplies of the vertebral column of rats have been examined by corrosion cast with Mercox CL2B(R). The close functional and topographic relationship of vessels to supplied structures were exposed by fractionated maceration of the soft tissues. The segmental arteries diverge into an anterior, median and posterior group with various anastomoses between their branches. Vertebral bodies and intervertebral discs are preferably supplied by branches of the anterior and median section. The vessels reaching the vertebral body from the dorsal side diverge in a treelike branching mode into the direction of the vertebral endplate. The venous drainage …
Industrial Problem Solving With Microbeam Analysis, Klara Kiss
Industrial Problem Solving With Microbeam Analysis, Klara Kiss
Scanning Microscopy
The objective of this paper is to provide an overview of the microbeam analytical techniques and to help select the appropriate one to solve complex problems often arising in today's high - tech industries. case histories are given to show how renowned analytical service laboratories and microbeam experts formulated their strategies to approach a real life problem, what type of conclusions were deduced from the data and, finally, how the problem was solved.
Microvascular Corrosion Casting Of The Lung. A State-Of-The-Art Review, Dean E. Schraufnagel
Microvascular Corrosion Casting Of The Lung. A State-Of-The-Art Review, Dean E. Schraufnagel
Scanning Microscopy
Corrosion casting and viewing of replicas with the scanning electron microscope is an excellent way to study the microvascular structure of the lung. This method can demonstrate aspects of the three-dimensional relationships, branching patterns, maximum diameters, arterio-venous connections, unusual sized and shaped capillaries, development and growth, neovascular structures and changes in development and disease better than any other means. Comparisons can be made in many experimental conditions and fundamental information obtained to answer physiologic questions. This paper reviews how the lung microvasculature has been studied by corrosion casting and scanning electron microscopy and indicates new areas where investigation might be …
Exposure Of Vascular Smooth Muscle Cells For Analysis With The Scanning Electron Microscope, Bryan G. Miller, Andrew P. Evan, H. Glenn Bohlen
Exposure Of Vascular Smooth Muscle Cells For Analysis With The Scanning Electron Microscope, Bryan G. Miller, Andrew P. Evan, H. Glenn Bohlen
Scanning Microscopy
There has been interest in using the scanning electron microscope (SEM) to study the structure of tissues obscured by other cellular or non-cellular elements almost since the SEM was first used to examine biological tissues. Such interest includes the vessel wall and, in particular, the vascular smooth muscle cells. This paper presents a review of the three basic methodologies that have been employed to allow examination of the vascular smooth muscle, 1) blunt dissection, 2) digestion and 3) microdissection. Discussion of other perivascular elements was not a focus of this review. Also presented is the application of these different methodologies …
Scanning Electron Microscope Studies On The Breakdown Of Passivity Of A Nickel-Chromium-Molybdenum Dental Alloy, J. Geis-Gerstorfer, W. Göpel, H. Weber
Scanning Electron Microscope Studies On The Breakdown Of Passivity Of A Nickel-Chromium-Molybdenum Dental Alloy, J. Geis-Gerstorfer, W. Göpel, H. Weber
Scanning Microscopy
The breakdown of passivity and localized corrosion of a Ni-20Cr-10Mo alloy was investigated. The methods employed were potentiodynamic polarization and SEM, and AES and EDX after potentiostatic polarization over a period of 20 hours in the passive and transpassive regions. The 1 μm finished as-cast specimens were polarized in aerated 0.1 M NaCl. The cyclic polarization curves revealed a critical pitting potential of 470 mv (SCE), while the protection potential was 300 mV (SCE). Using the potentiostatic polarization technique, nearly constant corrosion currents appeared, indicating that the whole surface was corroded uniformly. SEM pictures of samples, corroded at 650 mv, …
The Fine Structure Of The Human Placental Villus As Revealed By Scanning Electron Microscopy, G. J. Burton
The Fine Structure Of The Human Placental Villus As Revealed By Scanning Electron Microscopy, G. J. Burton
Scanning Microscopy
Scanning electron microscopy of the placenta has a history of only twenty years. During that time, however, there have been dramatic advances in instrument technology coupled with the refinement of preparative techniques designed to reduce fixation artifacts to a minimum. As a result many of the early claims must be amended or suitably qualified, and this is one aim of the present review.
Much new data on the internal structure of the placental villus is also presented. By means of the partial digestion technique it is now possible to describe the three dimensional configuration of the various components of the …
Electron Probe Micro-Analysis And Laser Microprobe Mass Analysis Of Material Leached From A Limestone Cathedral, L. A. Leysen, J. K. De Waele, E. J. Roekens, R. E. Van Grieken
Electron Probe Micro-Analysis And Laser Microprobe Mass Analysis Of Material Leached From A Limestone Cathedral, L. A. Leysen, J. K. De Waele, E. J. Roekens, R. E. Van Grieken
Scanning Microscopy
Electron probe X-ray micro-analysis (EPXMA) and Laser microprobe mass analysis (LAMMA), were applied to characterize the leachate of sandy limestones of a Belgian cathedral.
Individual suspended particles, found in water that was sprayed over the cathedral walls ("1 each ate water"), were sized and analyzed by automated EPXMA-analysis, and classified with hierarchical cluster methods. LAMMA was used to gather more information about particles, present in the solution, as well as in suspension.
It was found that the leachate from black walls, had a high sulphate concentration and a large variety of particles in suspension, with different morphology and composition, with …
The Clean Water Act, Water Quality, And Water Use, Bruce D. Ray
The Clean Water Act, Water Quality, And Water Use, Bruce D. Ray
Water as a Public Resource: Emerging Rights and Obligations (Summer Conference, June 1-3)
56 pages.
Includes unsigned annotations by David Getches.
Emerging Policy And Strategy Choices For Protection Of The Groundwater Resource, Richard H. Braun
Emerging Policy And Strategy Choices For Protection Of The Groundwater Resource, Richard H. Braun
Water as a Public Resource: Emerging Rights and Obligations (Summer Conference, June 1-3)
22 pages.
Contains 2 pages of references.
Adaptation Of Striped Bass To Sea Water Following Direct Transfer From Freshwater: Morphological, Biochemical, And Physiological Parameters, Judy A. King
Electronic Theses and Dissertations
There has been heightened interest in the biology of striped bass (Morone saxatilis) because of increased pollution in their native spawning grounds and because of their extensive use in landlocked sport fisheries. Their euryhalinity makes them an excellent species for osmoregulation studies. The objective of this research was to study the rate of adaptation of striped bass gills to sea water (3% salt) after direct transfer from freshwater using biochemical (ion transport enzyme levels), physiological (chloride efflux), and ultrastructural methods. Striped bass have specialized osmoregulatory cells located on the interlamellar and afferent surfaces of their gill filaments as shown by …
Fluoride Content In Home-Canned Fruits In Utah, Sydney Ann Mcdonald
Fluoride Content In Home-Canned Fruits In Utah, Sydney Ann Mcdonald
All Graduate Theses and Dissertations, Spring 1920 to Summer 2023
The purpose of this research was to determine whether or not canning fruit using fluoridated water made a difference in the fluoride contents of the juice and the pulp. Four cities in Utah were chosen. Two cities were fluoridated (Brigham City and Helper) and two cities were not fluoridated (North Ogden and Price). Three homes were chosen within each city, and three jars of canned fruit (one jar each of apricots, cherries, and peaches) were selected from each home. The fruit samples were freeze-dried, and then the fluoride was measured with a fluoride ion electrode. A difference was found in …
Sample Preparation For Surface And Interface Analysis, Siegfried Hofmann
Sample Preparation For Surface And Interface Analysis, Siegfried Hofmann
Scanning Microscopy
A survey of the most frequently used sample preparation methods for surface analysis methods such as Auger electron spectroscopy (AES), X-ray photoelectron spectroscopy (XPS), ion scattering spectroscopy (ISS) and secondary ion mass spectroscopy (SIMS) is presented. Ex-situ preparation before insertion of the sample into the ultrahigh vacuum (UHV) of the analysis chamber comprises common mechanical and chemical methods, whereas in-situ preparation is based on various UHV-compatible procedures like cleavage, fracture, heating and noble gas ion sputtering. Particular care is necessary to avoid misleading chemical and structural alterations of the sample surface. Advantages and limitations of the different approaches can only …
Scanning Electron Microscopy Of Vascular Corrosion Casts In Comparative Studies On Renal Vascular Structure, H. Ditrich, H. Splechtna
Scanning Electron Microscopy Of Vascular Corrosion Casts In Comparative Studies On Renal Vascular Structure, H. Ditrich, H. Splechtna
Scanning Microscopy
In comparative microcorrosion casting studies on renal vascular systems the following demands should be met: The preparation procedure (anaesthesia, operation, flushing of the blood vascular system, ...) should be in accord with the specific physiological properties of the animal under investigation and the casting procedure (injection, curing, maceration, ...) should be kept constant as far as possible. If these points are considered, comparative data, even of quantitative nature, can be obtained from corrosion casts. Examples of results at the organ, single vessel and intercellular level as well as correlation of the results with physiological data are given.
Study Of Rat Lung Alveoli Using Corrosion Casting And Freeze Fracture Methods Coupled With Digital Image Analysis, Alan C. Nelson
Study Of Rat Lung Alveoli Using Corrosion Casting And Freeze Fracture Methods Coupled With Digital Image Analysis, Alan C. Nelson
Scanning Microscopy
Relative areas and volumes can be estimated from vascular corrosion casts of rat lung alveoli using a calibration obtained from bulk frozen hydrated tissue. These morphometric measurements are roughly independent of the shrinkage and distortion artifacts known to arise in the corrosion casting procedure. Digital image processing of the SEM micrographs is employed to facilitate the measurement of casts and frozen tissue.
The vascular corrosion casting technique is modified also to permit successful casting of alveolar air passages. The modified technique produces faithful casts of dead-ended luminal structures where continuous perfusion of casting medium into the tissue is not possible. …
Tumor Vasculature In Young And Old Hosts: Scanning Electron Microscopy Of Microcorrosion Casts With Microangiography, Light Microscopy And Transmission Electron Microscopy, James G. Walmsley, Scott R. Granter, Miles P. Hacker, Ann L. Moore, William B. Ershler
Tumor Vasculature In Young And Old Hosts: Scanning Electron Microscopy Of Microcorrosion Casts With Microangiography, Light Microscopy And Transmission Electron Microscopy, James G. Walmsley, Scott R. Granter, Miles P. Hacker, Ann L. Moore, William B. Ershler
Scanning Microscopy
Tumor growth in vivo is dependent upon new blood vessel formation. When B16-F10 melanoma cells are implanted subcutaneously in young (3 mo) and old (24 mo) C57BL/6 mice the rate of growth is dependent on the age of the mice. This study involved a wide range of histological and microscopic techniques but was limited primarily to the initial phase of tumor growth. Stereological point counting from light microscopy (LM) of standard histological sections has been used to yield data regarding blood content. Tumor-bearing mice were perfused through the aorta with a fixation solution and were infused with a low-viscosity radiopaque …
Vascular Changes In Popliteal Lymph Nodes Due To Antigen Challenge In Normal And Lethally Irradiated Mice, Douglas A. Steeber, Chris M. Erickson, Kees C. Hodde, Ralph M. Albrecht
Vascular Changes In Popliteal Lymph Nodes Due To Antigen Challenge In Normal And Lethally Irradiated Mice, Douglas A. Steeber, Chris M. Erickson, Kees C. Hodde, Ralph M. Albrecht
Scanning Microscopy
The microvascular system of the murine popliteal lymph node was investigated using scanning electron microscopy of microcorrosion casts. Time-dependent changes in the microvasculature following regional antigen challenge in normal and lymphocyte-depleted mice were studied. Normal lymph node microvasculature exhibited a significant increase in both the vascular bed and post-capillary venules containing high-endothelium in response to antigen challenge. Lymph nodes of lymphocyte-depleted mice showed no microvascular size increase following antigen challenge and a reduction in the amount of high-endothelium was observed.
G87-845 Electrical Systems For Agricultural Buildings (Recommended Practices), Gerald R. Bodman, Laverne E. Stetson, Jack L. Schinstock
G87-845 Electrical Systems For Agricultural Buildings (Recommended Practices), Gerald R. Bodman, Laverne E. Stetson, Jack L. Schinstock
University of Nebraska-Lincoln Extension: Historical Materials
This NebGuide describes some of the specialized wiring practices and equipment required in agricultural buildings.
During June 1982, electrical system failures resulted in animal losses in excess of $100,000 on three Nebraska swine farms. In 1983, more than $45,000 worth of feeder pigs were electrocuted on another Nebraska farm. Dairy and beef animals also have been electrocuted--as have producers. A survey of more than 400 Nebraska farms revealed that over 50 percent have problems due to poor on-farm wiring. A more recent survey of 14 farms revealed none with 100 percent properly wired buildings. Many had conditions which were serious …
Ec87-419 Home Furnishings Care — Cleaning And Stain Removal, Shirley Niemeyer
Ec87-419 Home Furnishings Care — Cleaning And Stain Removal, Shirley Niemeyer
University of Nebraska-Lincoln Extension: Historical Materials
Furniture and accessories are a major investment. With proper care, furnishings can be a lifetime investment. Many new and tradtional materials are used in furnishings and accessories. Knowing how to care for these materials can prevent damage. Selecting the right product for the job will save time, money, frustration and disappointments; and do a better job. Procedures for caring for different types of furnishings materials are given in this booklet.