Open Access. Powered by Scholars. Published by Universities.®
- Institution
-
- Missouri University of Science and Technology (652)
- Purdue University (330)
- Technological University Dublin (328)
- University of Kentucky (208)
- University of Nebraska - Lincoln (175)
-
- University of Texas at Arlington (134)
- Louisiana State University (119)
- Utah State University (104)
- University of Central Florida (100)
- University of South Florida (92)
- California Polytechnic State University, San Luis Obispo (84)
- New Jersey Institute of Technology (79)
- Raynor Library Marquette University (74)
- Montana Tech Library (65)
- Air Force Institute of Technology (64)
- Clemson University (64)
- University of Nevada, Las Vegas (64)
- Brigham Young University (59)
- University of Arkansas, Fayetteville (58)
- Chulalongkorn University (54)
- Old Dominion University (46)
- Universitas Indonesia (45)
- West Virginia University (43)
- Michigan Technological University (40)
- Portland State University (37)
- University of South Carolina (37)
- National Taiwan Ocean University (36)
- University of Texas at El Paso (34)
- United Arab Emirates University (33)
- University of New Mexico (32)
- Keyword
-
- Engineering (316)
- Building (286)
- Construction (284)
- Architecture (262)
- Plumbing (199)
-
- Concrete (185)
- Corrosion (143)
- Durability (91)
- Bridges (65)
- Bridge (63)
- Steel (56)
- FRP (44)
- Reinforced concrete (40)
- Sustainability (39)
- Heating (36)
- Strengthening (28)
- Applied sciences (26)
- Fatigue (26)
- Kentucky transportation (26)
- Bridge deck (25)
- Drinking water (25)
- Rehabilitation (25)
- Composites (24)
- Fly ash (24)
- GFRP (24)
- Services (24)
- Cement (22)
- Inspection (22)
- Montana (22)
- Transportation (22)
- Publication Year
- Publication
-
- Building Services Engineering (292)
- Theses and Dissertations (210)
- Kentucky Transportation Center Research Report (152)
- Civil, Architectural and Environmental Engineering Faculty Research & Creative Works (130)
- International Conference on Durability of Concrete Structures (130)
-
- International Conference on Case Histories in Geotechnical Engineering (129)
- Electronic Theses and Dissertations (127)
- JTRP Technical Reports (110)
- USF Tampa Graduate Theses and Dissertations (88)
- Masters Theses (84)
- Civil Engineering Dissertations - Archive (77)
- Theses (76)
- Doctoral Dissertations (73)
- Bachelors Theses and Reports, 1928 - 1970 (62)
- CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018) (61)
- Publications (61)
- All Graduate Theses and Dissertations, Spring 1920 to Summer 2023 (56)
- Civil and Environmental Engineering Faculty Research and Publications (55)
- Civil Engineering Theses - Archive (52)
- ECT Fact Sheets Archive (47)
- Dissertations (44)
- Graduate Theses, Dissertations, and Problem Reports (ETD) (43)
- UNLV Theses, Dissertations, Professional Papers, and Capstones (43)
- All Theses (42)
- Graduate Theses and Dissertations (42)
- Chulalongkorn University Theses and Dissertations (Chula ETD) (41)
- Master's Theses (41)
- Nebraska Department of Transportation: Research Reports (41)
- American Iron and Steel Institute (AISI) Specifications, Standards, Manuals and Research Reports (1946 - present) (38)
- Makara Journal of Technology (37)
- Publication Type
- File Type
Articles 1861 - 1890 of 3988
Full-Text Articles in Entire DC Network
Str-829: Behavior Of Gfrp-Reinforced Concrete Squat Walls Under Simulated Earthquake Loading, Ahmed Arafa, Ahmed Sabry Farghaly, Brahim Benmokrane
Str-829: Behavior Of Gfrp-Reinforced Concrete Squat Walls Under Simulated Earthquake Loading, Ahmed Arafa, Ahmed Sabry Farghaly, Brahim Benmokrane
Canadian Society for Civil Engineering
Steel-reinforced squat walls are used as the main component for earthquake resistance in low-rise structures. Deterioration due to corrosion of steel reinforcement is one of the major challenges facing the construction industry. Furthermore, given the low aspect ratio of squat walls, their behavior is dominated by inelastic shear deformations activated by the yielding of flexural reinforcement. These deformations degrade strength and stiffness with subsequent shear failure, preventing the wall from achieving its flexural capacity, which is a prerequisite for adequate seismic design. Using noncorrodible glass-fiber-reinforced-polymer (GFRP) bars represents an effective method for overcoming corrosion problems. In addition, the available experimental …
Str-831: Fatigue Strength Of Angle-Shaped Transverse Connection For Gfrp-Reinforced Precast Full-Depth Deck Panels In Accelerated Bridge Construction, Mahmoud Sayed-Ahmed, Khaled Sennah
Str-831: Fatigue Strength Of Angle-Shaped Transverse Connection For Gfrp-Reinforced Precast Full-Depth Deck Panels In Accelerated Bridge Construction, Mahmoud Sayed-Ahmed, Khaled Sennah
Canadian Society for Civil Engineering
Prefabricated bridges elements and systems (PBES) are subjected to repeated truck loads while being exposed to weather conditions. Fatigue of the structural elements and corrosion of the reinforcement are the main reasons for bridge deterioration. This research investigates the fatigue strength of full-depth deck panels (FDDP) resting over steel cross-braced girders and reinforced with ribbed-surface, high-modulus (HM), glass fiber reinforced polymer (GFRP) bars. The precast FDDP has transverse panel-to-panel connection of angle-shape with female shear key, and panel-to-girder connection of V-shape, where both connections are filled with ultra-high performance fiber reinforced concrete (UHPFRC). Two different fatigue loading were conducted to …
Str-844: Cover Crack Growth Monitoring In Rc Structures Subjected To Corrosion With Acoustic Emission Sensors, Ahmed A. Abouhussien, Assem A. A. Hassan
Str-844: Cover Crack Growth Monitoring In Rc Structures Subjected To Corrosion With Acoustic Emission Sensors, Ahmed A. Abouhussien, Assem A. A. Hassan
Canadian Society for Civil Engineering
This paper investigates the feasibility of applying acoustic emission (AE) monitoring to evaluate the cover cracking caused by reinforcing steel corrosion in concrete structures. Ten small-scale reinforced concrete prism samples were continuously monitored using attached AE sensors as being exposed to accelerated corrosion tests. The samples had a constant concrete cover (40 mm) around one embedded steel bar and were corroded to reach five percentages of steel mass loss: 1%, 2%, 3%, 4%, and 5%. Several AE signal parameters including number of hits, signal strength, energy, amplitude, and peak frequency were acquired during the tests. The AE signal strength data …
Str-845: Condition Assessment Of Corroded Reinforcement Bond To Concrete By Acoustic Emission Monitoring, Ahmed A. Abouhussien, Assem A. A. Hassan
Str-845: Condition Assessment Of Corroded Reinforcement Bond To Concrete By Acoustic Emission Monitoring, Ahmed A. Abouhussien, Assem A. A. Hassan
Canadian Society for Civil Engineering
In this paper, acoustic emission (AE) monitoring was used to evaluate the bond behaviour of corroded reinforcement in reinforced concrete prism samples. The embedded reinforcing steel bars were pre-corroded to successive levels of corrosion up to 5% mass loss of steel by impressed current accelerated corrosion process. A total of 24 samples with variable bar embedded length (50 and 200 mm) and corrosion exposure (0%, 1%, 2%, 3%, 4%, and 5% of steel mass loss) were tested under pull-out tests. Two attached AE sensors were mounted at the surface of each specimen to continuously record the emitted AE signals throughout …
Str-888: Flexural Tests Of Continuous Concrete Slabs Reinforced With Basalt Fiber-Reinforced Polymer Bars, Mohammad Akiel, Tamer El-Maaddawy, Ahmed El Refai
Str-888: Flexural Tests Of Continuous Concrete Slabs Reinforced With Basalt Fiber-Reinforced Polymer Bars, Mohammad Akiel, Tamer El-Maaddawy, Ahmed El Refai
Canadian Society for Civil Engineering
Continuous steel-reinforced concrete slabs are vulnerable to corrosion damage and cracking. Non-metallic basalt fiber-reinforced polymer (BFRP) bars have a great potential to overcome corrosion problems. In this paper, test results of six continuous concrete slabs internally-reinforced with BFRP bars are reported. The specimens were divided into two groups based on the BFRP reinforcement ratio in the sagging regions (2.5Pfb and 0.8Pfb), where Pfb is the balanced reinforcement ratio of BFRP reinforcement. In each group, the hogging-to-sagging BFRP reinforcement ratio was 0.5, 0.72, or 1. Increasing the hogging-to-sagging BFRP reinforcement ratio increased the ultimate load but had almost …
Str-895: Moment Redistribution Of Gfrp-Rc Continuous T-Beams, S. M. Hasanur Rahman, Ehab El-Salakawy
Str-895: Moment Redistribution Of Gfrp-Rc Continuous T-Beams, S. M. Hasanur Rahman, Ehab El-Salakawy
Canadian Society for Civil Engineering
Fiber-reinforced polymer (FRP) bars have proven to be an excellent alternative to steel bars in many concrete structures such as parking garages and overpasses that are susceptible to harsh environments and consequently corrosion of steel reinforcement. In these structures, FRP reinforced concrete (FRP-RC) continuous beams are common members. Moment redistribution in FRP-RC continuous beams has not been well established yet because of the different characteristics of FRP bars such as linear-elastic stress-strain relationship and lower modulus of elasticity compared to conventional steel. Recent studies showed that redistribution of internal forces in Glass (G) FRP-RC continuous beams with a rectangular section …
Str-894: Bond Strength Of Ribbed-Surface High-Modulus Glass Frp Bars Embedded Into Unconfined Uhpfrc, Mahmoud Sayed-Ahmed, Khaled Sennah
Str-894: Bond Strength Of Ribbed-Surface High-Modulus Glass Frp Bars Embedded Into Unconfined Uhpfrc, Mahmoud Sayed-Ahmed, Khaled Sennah
Canadian Society for Civil Engineering
High-modulus (HM) ribbed-surface glass fiber reinforced polymer (GFRP) bars have recently been used in concrete bridge decks to avoid corrosion of steel reinforcement resulting from the use of de-icing salts in winter times in North America. Recently, prefabricated full-depth deck panels (FDDPs), made of normal strength concrete or high performance concrete and reinforced with GFRP bars, are used in Canada to acceleration bridge construction. The FDDPs are connected through panel-to-panel and panel-to-girder connections. These connections are filled with joint-filled cementitious materials as ultra-high performance fiber-reinforced concrete (UHPFRC). This paper presents the experimental program to investigate the bond strength of the …
Str-937: Behaviour Of Frp-Reinforced Cfft Columns Under Axial Compression Loading, Asmaa Abdeldaim Ahmed, Radhouane Masmoudi
Str-937: Behaviour Of Frp-Reinforced Cfft Columns Under Axial Compression Loading, Asmaa Abdeldaim Ahmed, Radhouane Masmoudi
Canadian Society for Civil Engineering
This paper presents the test results of an experimental study aimed at investigating the axial behaviour of CFFT columns internally reinforced with steel and FRP bars. A total of eight reinforced concrete (RC) and concrete-filled FRP tube (CFFT) columns were constructed and tested until failure. All columns had 1900-mm in height and 213-mm in diameter. The test parameters were: (1) internal reinforcement type (steel, glass FRP (GFRP), or carbon FRP (CFRP) bars) and amount, (2) GFRP tube thicknesses, and (3) nature of axial loading type (i.e. monotonic and cyclic). The experimental results revealed that the CFFT columns reinforced with GFRP …
Str-953: Burst Pressure Assessment For Pipelines With Multiple Corrosion Defects, Bipul Chandra Mondal, Ashutosh Sutra Dhar
Str-953: Burst Pressure Assessment For Pipelines With Multiple Corrosion Defects, Bipul Chandra Mondal, Ashutosh Sutra Dhar
Canadian Society for Civil Engineering
Pipeline with multiple corrosion defects are often observed in the field. The strength of pipe with multiple corrosion patches depends on the corrosion patch intensity, their locations along longitudinal and circumferential directions of the pipe, in addition to the parameters influencing the strength of pipe with single corrosion defect. The existing design codes recommend the spacing between the corrosion patches when the interacting corrosion patches can be considered as a single patch for calculating the burst pressure of the defected pipe. In this paper, the strength and deformation characteristics of corroded pipe are investigated using finite element analysis. The parameters …
Str-961: Frp Shear Connectors For Reinforced Concrete Composite Elements, Jehad Alkatan, Amr El Ragaby, Faouzi Ghrib
Str-961: Frp Shear Connectors For Reinforced Concrete Composite Elements, Jehad Alkatan, Amr El Ragaby, Faouzi Ghrib
Canadian Society for Civil Engineering
Currently, friction shear dowels (steel stirrups) are being used in bridge construction at the interface plane between the cast-in-place deck slab and the precast girder to ensure the composite action for stronger cross section. As the bridge deck slab deteriorated over time due to the environmental conditions, these shear steel dowels are also susceptible to sever corrosion and will need replacement, especially when de-icing salt is used. This results in gradual loss of the composite behavior and strength of the composite section. Fiber reinforced polymers (FRPs) reinforcements have shown to be an effective alternative to black steel as flexure and …
Str-968: Wavelet Entropy-Based Damage Identification Technique For Hybrid Frp-Concrete Structures, Mohammad Moravvej, Mamdouh El-Badry, Parham Joulani
Str-968: Wavelet Entropy-Based Damage Identification Technique For Hybrid Frp-Concrete Structures, Mohammad Moravvej, Mamdouh El-Badry, Parham Joulani
Canadian Society for Civil Engineering
Civil infrastructure, particularly bridges, is designed and built to be safe against failure and to perform satisfactorily during their service life. However, this infrastructure has been deteriorating at an alarming rate due to aging, inadequate maintenance, adverse environmental conditions, and constantly growing transportation demand. Utilization of corrosion-resistant composite materials, particularly fibre-reinforced polymers (FRP), has been an encouraging solution for the durability problems of concrete bridges. However, similar to conventional structures, the performance of hybrid FRP-concrete structures can be affected by various types of damage. Therefore, in order to ensure both safety and serviceability of these structures, it is essential to …
Str-973: Static Load Behaviour Of Hybrid Frp-Concrete Two-Panel Truss Girders Reinforced With Double-Headed Gfrp Bars, Parham Joulani, Mamdouh El-Badry, Mohammad Moravvej
Str-973: Static Load Behaviour Of Hybrid Frp-Concrete Two-Panel Truss Girders Reinforced With Double-Headed Gfrp Bars, Parham Joulani, Mamdouh El-Badry, Mohammad Moravvej
Canadian Society for Civil Engineering
The results of an experimental investigation into the behaviour of precast hybrid FRP-concrete, two-panel truss girders under static loading are presented. The investigation is part of a comprehensive research program on the development of a corrosion-free system for short and medium span bridges. The truss girders consist of pretensioned concrete chords connected by vertical and diagonal truss elements made of glass FRP tubes filled with concrete. The truss elements are reinforced and connected to the top and bottom chords by means of long double-headed steel or glass FRP bars. The top and bottom chords are also reinforced with glass FRP …
Str-999: Intelligent Monitoring System Reveals New Information About The Champlain Bridge, Ehsan Sobhani, Armineh Garabedian, Dominic Lavigne, Chakib Kassem, René Tinawi
Str-999: Intelligent Monitoring System Reveals New Information About The Champlain Bridge, Ehsan Sobhani, Armineh Garabedian, Dominic Lavigne, Chakib Kassem, René Tinawi
Canadian Society for Civil Engineering
The Champlain Bridge, constructed in 1957, is one of Canada’s busiest and most economically critical bridges. This 3.4km-long bridge consists of as many as 50 simply supported spans, 50 to 53 m long, plus an elevated truss structure over the Saint Lawrence Seaway. Each span has a cross-section of seven precast post-tensioned girders supporting cast-in-place infill strips that constitute a deck with six traffic lanes. Like many other structures, Champlain Bridge is subjected to environmental, traffic or hydrological loads, which adversely affect the structural condition of the bridge. This structural degradation is further accelerated for the Champlain Bridge due to …
Friction Bit Joining Of Dissimilar Combinations Of Gadp 1180 Steel And Aa 7085 – T76 Aluminum, Lorne Steele Atwood
Friction Bit Joining Of Dissimilar Combinations Of Gadp 1180 Steel And Aa 7085 – T76 Aluminum, Lorne Steele Atwood
Theses and Dissertations
Friction Bit Joining (FBJ) is a method used to join lightweight metals to advanced high-strength steels (AHSS). The automotive industry is experiencing pressure to improve fuel efficiency in their vehicles. The use of AHSS and aluminum will reduce vehicle weight which will assist in reducing fuel consumption. Previous research achieved joint strengths well above that which was required in three out of the four standard joint strength tests using DP980 AHSS and 7075 aluminum. The joints were mechanically tested and passed the lap-shear tension, cross-tension, and fatigue cycling tests. The t-peel test configuration never passed the minimum requirements. The purpose …
Evaluation Of The Use Of Painted And Unpainted Weathering Steel On Bridges, Theodore Hopwood Ii, Sudhir Palle, Bobby W. Meade, Rick Younce
Evaluation Of The Use Of Painted And Unpainted Weathering Steel On Bridges, Theodore Hopwood Ii, Sudhir Palle, Bobby W. Meade, Rick Younce
Kentucky Transportation Center Research Report
KTC researchers studied the use of unpainted weathering steel on bridges, using findings of inspections performed on Kentucky Transportation Cabinet (KYTC) bridges constructed with both painted and unpainted weathering steel as well as laboratory testing. Laboratory tests were conducted on test panels of conventional and weathering grades of steel to determine the performance of barrier and zinc-based coatings over abrasive-blasted substrates of those steel types in both the new and corroded conditions. The report provides the following recommendations for the use of painted and unpainted weathering steel on Kentucky bridges based upon both the field and laboratory findings:
- KYTC should …
The Design And Construction Of A Rear Bumper With Incorporated Spare Tire Rack, Alan C. Isaacson
The Design And Construction Of A Rear Bumper With Incorporated Spare Tire Rack, Alan C. Isaacson
BioResource and Agricultural Engineering
This senior project outlines the design and construction of a rear bumper with incorporated spare tire and equipment rack for a 1946 Willys CJ2A Jeep. The spare tire rack is capable of swinging out away from the vehicle to allow for the use of the vehicle’s tailgate. The bumper was designed for strength, functionality and aesthetic qualities alike. Additionally, the bumper design considered all vehicle codes and regulations.
Performance Assessment Of Deteriorated And Retrofitted Steel Hp Piles, Joshua Steelman, Steven Stauffer
Performance Assessment Of Deteriorated And Retrofitted Steel Hp Piles, Joshua Steelman, Steven Stauffer
Nebraska Department of Transportation: Research Reports
No abstract provided.
Design Of Magnesium Phosphate Cement Based Composite For High Performance Bipolar Plate Of Fuel Cells, Wenbin Hao, Hongyan Ma, Zeyu Lu, Guoxing Sun, Zongjin Li
Design Of Magnesium Phosphate Cement Based Composite For High Performance Bipolar Plate Of Fuel Cells, Wenbin Hao, Hongyan Ma, Zeyu Lu, Guoxing Sun, Zongjin Li
Civil, Architectural and Environmental Engineering Faculty Research & Creative Works
In this work, we report a comprehensive study on a magnesium phosphate cement (MPC) based composite as the construction material for high performance bipolar plates of fuel cells. MPC with partial replacement of fly ash was employed as the binding matrix. Some carbon-based materials, such as graphite, carbon black, carbon fiber, and multi-walled carbon nanotubes were used to construct the conductive phase. A simple hot-press process was applied to produce the composite. The formula and the structure of the composite was modified and adjusted to optimize the properties of the composite to meet the US DOE 2015 technical targets, including …
A Comparison Of Risk Assessment Models For Pipe Replacement And Rehabilitation In A Water Distribution System, Lyle John Nemeth
A Comparison Of Risk Assessment Models For Pipe Replacement And Rehabilitation In A Water Distribution System, Lyle John Nemeth
Master's Theses
A water distribution system is composed of thousands of pipes of varying materials, sizes, and ages. These pipes experience physical, environmental, and operational factors that cause deterioration and ultimately lead to their failure. Pipe deterioration results in increased break rates, decreased hydraulic capacity, and adverse effects on water quality. Pipe failures result in economic losses to the governing municipality due to loss of service, cost of pipe repair/replacement, damage incurred due to flooding, and disruptions to normal business operations. Inspecting the entire water distribution system for deterioration is difficult and economically unfeasible; therefore, it benefits municipalities to utilize a risk …
Feasibility Study And Optimization Of The Structural Design Of Locks Made Out Of Plain Concrete, A. Tahir, C. Kunz, K. Terheiden
Feasibility Study And Optimization Of The Structural Design Of Locks Made Out Of Plain Concrete, A. Tahir, C. Kunz, K. Terheiden
International Junior Researcher and Engineer Workshop on Hydraulic Structures
No abstract provided.
Volatile Organic Compound (Voc) Emission During Cured-In-Place-Pipe (Cipp) Sewer Pipe Rehabilitation, Elena Bourbour Ajdari
Volatile Organic Compound (Voc) Emission During Cured-In-Place-Pipe (Cipp) Sewer Pipe Rehabilitation, Elena Bourbour Ajdari
LSU New Orleans Theses and Dissertations
The maintenance or replacement of deteriorated pipes and culverts is a constant and significant concern for municipalities and transportation agencies in the United States (Donaldson and Wallingford, 2010). Trenchless technologies and especially the Cured-in-place pipe (CIPP) method have become increasingly common ways to preserve infrastructures owing to their feasibility, cost-effectiveness, and fewer social impacts (Jung and Sinha, 2007). Therefore, there is a growing need to understand the direct and indirect effects of pipeline rehabilitation activities on the environment. Nearly all past CIPP studies have focused on its mechanical properties, and its environmental impacts are poorly investigated and documented (Allouche et …
Odor Monitoring At The New Orleans East Bank Wastewater Treatment Plant, Felicia R. Figinsky
Odor Monitoring At The New Orleans East Bank Wastewater Treatment Plant, Felicia R. Figinsky
LSU New Orleans Theses and Dissertations
Hydrogen Sulfide is a corrosive, odorous, and hazardous gas that can cause issues for wastewater collection systems and treatment plants. When evaluating hydrogen sulfide concentrations it is important to consider the source, odor causing mechanism, and its level of toxicity. In this study, continuous hydrogen sulfide monitoring was performed for 8 locations within the New Orleans East Bank Wastewater Treatment Plant for a span of 5 months. Hot spots within the plant are located and data analysis is performed based on daily and hourly averages of hydrogen sulfide concentrations. The data was configured to show peak hydrogen sulfide concentrations at …
Cost Effective Manhole To Pipe Connection, Utkarsh Shekhar
Cost Effective Manhole To Pipe Connection, Utkarsh Shekhar
Master of Technology Management Plan II Graduate Projects
The manhole to the pipe connection is an important part of the sewer system. Any problem in the seal connecting the manhole to the pipe results into either inflow of ground water into the sewer system or outflow into the surrounding environment. The inflow of ground water on one hand increases the volume of wastewater being sent to the wastewater plant and on the other hand, the outflow leads to the contamination of the surrounding soil. Hence, the durability and longevity of the manhole to the pipe connection is crucial.
The manhole to the pipe connection generally fails due to …
Cyclic Loading Behavior Of Cfrp-Wrapped Non-Ductile Reinforced Concrete Beam-Column Joints, Ali S. H. Zerkane
Cyclic Loading Behavior Of Cfrp-Wrapped Non-Ductile Reinforced Concrete Beam-Column Joints, Ali S. H. Zerkane
Dissertations and Theses
Use of fiber reinforced polymer (FRP) material has been a good solution for many problems in many fields. FRP is available in different types (carbon and glass) and shapes (sheets, rods, and laminates). Civil engineers have used this material to overcome the weakness of concrete members that may have been caused by substandard design or due to changes in the load distribution or to correct the weakness of concrete structures over time specially those subjected to hostile weather conditions. The attachment of FRP material to concrete surfaces to promote the function of the concrete members within the frame system is …
Impact Of Extreme Summer Temperatures On Bridge Structures, Ryan Hagedorn
Impact Of Extreme Summer Temperatures On Bridge Structures, Ryan Hagedorn
Graduate Theses and Dissertations
Climate change and its effect on weather in the United States is a well-documented phenomenon. In particular, extreme heat waves have become more intense, more frequent, and longer lasting, especially in the southern United States. As with much of America’s transportation infrastructure, prestressed concrete bridge girders experience the effects of these heat waves. Uneven heating of optimized bridge girder sections results in large non-linear temperature gradients. In this study, temperature was monitored in three different AASHTO I-girders to determine the vertical and transverse temperature gradients in a pre-deck placement condition. It was determined that the current design standard, which uses …
Development Of The Masw Method For Pavement Evaluation, Benjamin J. Davis
Development Of The Masw Method For Pavement Evaluation, Benjamin J. Davis
Graduate Theses and Dissertations
The purpose of this research is to establish a recommended procedure for performing multichannel analysis of surface waves (MASW) on pavements as well as evaluating the ability of MASW to detect a change in shear wave velocity as damage in concrete increases. The tests for establishing a recommended procedure for performing MASW on pavements was conducted at five sites at the University of Arkansas Engineering Research Center in Fayetteville, Arkansas. The five sites consisted of three materials: asphalt, concrete, and soil (two sites were on asphalt, two were on concrete, and one was on soil). The methods evaluated at these …
Strengthening Of Lightweight Reinforced Concrete Beams Using Carbon Fiber Reinforced Polymers (Cfrp), Tariq Al Jaafreh
Strengthening Of Lightweight Reinforced Concrete Beams Using Carbon Fiber Reinforced Polymers (Cfrp), Tariq Al Jaafreh
Civil Engineering Theses - Archive
This research aimed to investigate the effect of utilizing “Fiber Reinforced Polymer” (FRP) on the light weight concrete beams. The main hypothesis is that such utilization of the FRP will lead to strengthened lightweight beams. The research that has been done on this relationship is somewhat broad in the scope and have mostly focused on the normal-weight concrete. However, only few studies that have considered the light weight concrete. Eight Beams were tested in this research under four point bending test. Two beams were taken as a control beams without any external bonding of Carbon Fiber Reinforced polymer. Another two …
Rhizosphere Interactions Between Copper Oxide Nanoparticles And Wheat Root Exudates In A Sand Matrix; Influences On Bioavailability And Uptake, Paul Mcmanus
All Graduate Theses and Dissertations, Spring 1920 to Summer 2023
Copper oxide nanoparticles (CuO NPs) are extremely small particles (less than 1 nm in one or more dimension, or one billionth (10-9) of a meter) used in a diverse range of industries. They have been shown to travel through water systems, and like pharmaceuticals, can end up in wastewater treatment plants and then be land applied as biosolids, where crops are grown for animal consumption, potentially leading to food chain accumulation.
Cu is an essential micronutrient for plants, but is phytotoxic at higher concentrations. CuO NPs present an increasingly real environmental threat to agriculture in soils treated with …
Live-Load Test And Finite-Element Model Analysis Of A Steel Girder Bridge, Jake L. Morrill
Live-Load Test And Finite-Element Model Analysis Of A Steel Girder Bridge, Jake L. Morrill
All Graduate Theses and Dissertations, Spring 1920 to Summer 2023
The Utah Transportation Center in conjunction with the Mountain Plains Consortium sponsored a study to investigate the performance, and condition of a steel, twin, I-girder bridge. The bridge is located on the Idaho-Oregon border near Payette, Idaho, and was designed to carry traffic over the Snake River.
Bridge Diagnostics Inc. was contracted by the Idaho Transportation Department to perform a live-load test on the bridge. This testing included the placement of 62 gauges that measured the response of the bridge as heavy trucks were driven across it.
A 3-D finite-element model of the bridge was generated and compared to the …
Structural Retrofit Of Reinforced Concrete Circular Columns Using Cfrp, Ahmed Haider Mohiuddin
Structural Retrofit Of Reinforced Concrete Circular Columns Using Cfrp, Ahmed Haider Mohiuddin
Civil Engineering Theses - Archive
Fiber reinforced polymer (FRP) composites have developed numerous applications in the field of Civil Engineering, mostly because of their beneficial properties like high strength-to=weight ratio and high corrosion resistance. This study presents an easy and expedient finite element (FE) able to accurately estimate the axial load carrying capacity of reinforced concrete (RC) circular columns confined with externally bonded carbon fiber reinforced polymer (CFRP) sheets. The element is able to model collapse due to concrete crushing. The FE generated in this study is used the load carrying capacity of CFRP confined RC columns subjected to concentric loading. Constitutive models for materials …