An Experimental Study On Effect Of Steel Corrosion On The Bond–Slip Performance Of Reinforced Concrete, Xiaolin Zhang, Xuebing Liang, Hancheng Huang, Haijun Zhou Jun 2016

An Experimental Study On Effect Of Steel Corrosion On The Bond–Slip Performance Of Reinforced Concrete, Xiaolin Zhang, Xuebing Liang, Hancheng Huang, Haijun Zhou

International Conference on Durability of Concrete Structures

This paper studied the effects of reinforcement corrosion on bond performance between rebar and concrete. Tests were carried out to evaluate the degradation of bond between reinforcing steel and concrete for different corrosion levels of reinforcing steel. A series of 20 specimens of different concrete strength with various reinforcing steel corrosion levels were designed and manufactured. Each specimen was casted as a 200-mm concrete cube, and a steel rebar was centrally embedded with two stirrups around it. The steel rebar were corroded using an electrochemical accelerated corrosion technique. The corrosion crack opening width and length were recorded after the corrosion …


Threshold Chloride Concentration Of Stainless Steels In Simulated Concrete Pore Solution, Hailong Wang, Jiayan Ling, Xiaoyan Sun Jun 2016

Threshold Chloride Concentration Of Stainless Steels In Simulated Concrete Pore Solution, Hailong Wang, Jiayan Ling, Xiaoyan Sun

International Conference on Durability of Concrete Structures

To evaluate whether stainless steel can replace carbon steel as rebar in reinforced concrete structures exposed to aggressive environment, the threshold chloride concentration of carbon steel, austenitic and duplex stainless steels were experimentally studied in this paper. The solutions with pH ranging from 9.5 to 13.6 were used herein to simulate the pore liquids in both alkaline and carbonated concretes. Potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) tests were carried out in the solutions with chloride concentration ranging from 0 to 5.0M and at a temperature around 25°C. The activation of pitting corrosion was determined when corrosion current increased and …


Corrosion-Induced Concrete Cracking Model Considering Corrosion-Filled Paste, Jianfeng Dong, Yuxi Zhao, Yingyao Wu, Weiliang Jin Jun 2016

Corrosion-Induced Concrete Cracking Model Considering Corrosion-Filled Paste, Jianfeng Dong, Yuxi Zhao, Yingyao Wu, Weiliang Jin

International Conference on Durability of Concrete Structures

A TCP–TCL model is established to describe the relationship between the thickness of the corrosion-filled paste (CP) and that of the corrosion layer (CL). This model can describe the phenomenon that the corrosion filling in the concrete pores and accumulating at the steel/concrete interface occur synchronously. Based on the TCP–TCL model, a corrosion-induced concrete cracking model, which can quantitatively consider corrosion-filled paste at concrete/steel interface, is proposed. Combined with damage analysis in corrosion-induced cracking process of concrete cover, the model is developed to describe the quantity of steel corrosion required to crack …


Designing Repeatable Self-Healing Into Cementitious Materials, Mo Li, Shuai Fan Jun 2016

Designing Repeatable Self-Healing Into Cementitious Materials, Mo Li, Shuai Fan

International Conference on Durability of Concrete Structures

Designing self-healing into cementitious materials can open a new world of opportunities for resilient concrete infrastructure under service loading conditions. The self-healing process should be robust as well as repeatable, allowing for self-repair after multiple damage events. The repeatability poses great challenges when self-healing strategies mainly rely on the formation of low-strength calcium carbonate healing product, complicated by the localized cracking behavior of cementitious materials. This study aims at formulating a new cementitious material system with designed physical and chemical characteristics that favour repeatable self-healing. Advanced experimental methods, coupled with micromechanics theory, are adopted to probe and design repeatable self-healing …


Progress In Durability Study Of Frp Materials, Zeng-Zhu Zhu, Ying-Wu Zhou, Li-Li Sui, Feng Xing, Jia Du Jun 2016

Progress In Durability Study Of Frp Materials, Zeng-Zhu Zhu, Ying-Wu Zhou, Li-Li Sui, Feng Xing, Jia Du

International Conference on Durability of Concrete Structures

During the past decades, FRP strengthened RC structures have attracted worldwide interest in both application and research. Nowadays, as more and more infrastructures are being suffered from severe corrosions due to harsh and extreme environments, the durability of FRP strengthened RC structures has generally emerged as the most important issue in research. Thus, the paper presents the latest progress in durability study of the FRP materials through an in-depth review and analysis on existing extensive investigations. The time-dependent performances of two types of FRP materials of carbon FRP (CFRP) and glass FRP (GFRP) under severe environments of humidity, high temperature, …


Durability-Based Optimal Design Methodology For Rc Members In Corrosive Environment, Saeid A. Alghamdi, Shamsad Ahmad, Adamu Lawan Jun 2016

Durability-Based Optimal Design Methodology For Rc Members In Corrosive Environment, Saeid A. Alghamdi, Shamsad Ahmad, Adamu Lawan

International Conference on Durability of Concrete Structures

No abstract provided.


Investigation Of The Spatial Variability Of Steel Weight Loss And Corrosion Cracking: A Novel X-Ray Technique, Sopokhem Lim, Haitao Jiang, Mitsuyoshi Akiyama Jun 2016

Investigation Of The Spatial Variability Of Steel Weight Loss And Corrosion Cracking: A Novel X-Ray Technique, Sopokhem Lim, Haitao Jiang, Mitsuyoshi Akiyama

International Conference on Durability of Concrete Structures

The performance of corrosion-affected RC members depends strongly on localized damages of reinforcement. Therefore, modeling the spatial variability of steel corrosion is very important for the assessment of the remaining service life of corroded structures or time for maintenance. To study the changes of spatial variability of steel weight loss over time, a continuous monitoring is necessary. In this paper, a novel procedure of X-ray technique application in monitoring the spatial growth of a corroded bar in a RC specimen is demonstrated along with the digital image processing of X-ray images to estimate the steel weight loss. The relationship of …


Influence Of Concrete Moisture Condition On Half-Cell Potential Measurement, Sylvia Kessler, Christoph Gehlen Jun 2016

Influence Of Concrete Moisture Condition On Half-Cell Potential Measurement, Sylvia Kessler, Christoph Gehlen

International Conference on Durability of Concrete Structures

The detection of on-going corrosion is one of the main issues during inspection of reinforced concrete structures. The half-cell potential measurement method is the most common and established non-destructive technique to support this task. But a lot of infrastructures are exposed to rain or seawater, which can cause heterogeneous moisture condition within one component. In turn, this can have influence on the potential mapping results, and as a consequence, the interpretability of the half-cell potential measurement is impaired. This paper focuses on the influence of concrete moisture condition on half-cell potential measurement. Laboratory and practical tests’ results are analyzed qualitatively …


Electrical Response Of Mortar Saturated With Nacl Solutions Under Freeze–Thaw Cycles, Yi Wang, Fuyuan Gong, Tamon Ueda, Dawei Zhang Jun 2016

Electrical Response Of Mortar Saturated With Nacl Solutions Under Freeze–Thaw Cycles, Yi Wang, Fuyuan Gong, Tamon Ueda, Dawei Zhang

International Conference on Durability of Concrete Structures

This paper presents the test results of electrical response of mortar saturated with sodium chloride (NaCl) solutions under freeze–thaw cycles (FTCs). To quantitatively evaluate the salt frost damage of mortar based on its electrical response, mesoscale samples are prepared to assure the uniform pore solution concentration. The reduction of electrical resistivity shows the same tendency with elastic modulus, but with less degree. The investigation shows that electrical resistivity of mortar decreases with temperature and the phase changes can be observed based on their relationship. The freezing and thawing points decreasing with increment of solution concentration can be found, but their …


Effect Of Bfrp Grid On Crack Propagation Of Reinforced Concrete Beam With Thick-Cover Concrete, Li-Juan Cheng, Hua-Nan He Jun 2016

Effect Of Bfrp Grid On Crack Propagation Of Reinforced Concrete Beam With Thick-Cover Concrete, Li-Juan Cheng, Hua-Nan He

International Conference on Durability of Concrete Structures

For the purpose of solving the problem of large crack width in concrete beam with thick cover, BFRP grid is added to the concrete cover to control the crack development and to improve the distribution status of cracks. In this paper, the bending tests under four-point loading are adopted to investigate cracking properties of reinforced concrete beams with thick cover, in which BFRP grid is added. During test cracking load, crack width and the number of crack were recorded, which will be analysed later. Test results show that crack development of reinforced concrete beam with thick cover can be effectively …


Effect Of Pet Wrapping On Shear Performance Of Corroded Reinforced Concrete Columns, Dawei Zhang, Yuxi Zhao, Weiliang Jin, Tamon Ueda Jun 2016

Effect Of Pet Wrapping On Shear Performance Of Corroded Reinforced Concrete Columns, Dawei Zhang, Yuxi Zhao, Weiliang Jin, Tamon Ueda

International Conference on Durability of Concrete Structures

In this paper, an experimental study is presented on the influence of PET warping on shear performance, such as diagonal shear cracking load, peak load, and energy dissipation of RC columns with stirrup corrosion before strengthening. The experimental program involved an electrochemical process to accelerate the migration of chlorides from an external electrolyte into the tested columns, a wetting–drying cycle process with a controlled current to speed up the corrosion of the stirrup in the tested columns, the strengthening of corroded columns with PET warping, and a pseudostatic test to determine the shear capacity of the tested beams. The shear …


Research On Concrete Durability Improving For Existing Island-Building And Its Application, Mao Jianghong, Zhu Yaofeng, Xu Fangyuan, Jin Weiliang, Xu Yidong, Chen Xu Jun 2016

Research On Concrete Durability Improving For Existing Island-Building And Its Application, Mao Jianghong, Zhu Yaofeng, Xu Fangyuan, Jin Weiliang, Xu Yidong, Chen Xu

International Conference on Durability of Concrete Structures

China’s coastal cities contain a large number of islands with abundant human activities, in which buildings are in a typical marine corrosion environment and the corrosion of reinforced concrete structures is very prominent. This paper makes research work on two aspects: (1) the durability assessment and durability improvement after a thorough investigation of the architecture of Xiangtan County, Ningbo city, on an island and (2) the application research of the bidirectional electromigration rehabilitation (BIEM) technology to enhance the durability of existing island building life. This paper designs a set of BIEM equipment based on solar power supply and develops a …


Chloride Penetration In Surface-Treated Concrete In Natural And Accelerated Environments, Jianfeng Dong, Yuxi Zhao, Shaoliang Pu, Ming Ji Jun 2016

Chloride Penetration In Surface-Treated Concrete In Natural And Accelerated Environments, Jianfeng Dong, Yuxi Zhao, Shaoliang Pu, Ming Ji

International Conference on Durability of Concrete Structures

This study investigated the chloride penetration of surface-treated concrete in natural and accelerated environments. A part of a real concrete port, including the beams and the columns, was investigated. Concrete specimens cast together with the concrete port were transported to the lab and subjected to wetting and drying cycles for accelerating the ingression of chloride ion. Chloride concentration of the specimens in the lab and the components in situ was tested. The results show that the surface treatments obviously slow down the chloride penetration into the concrete in both lab and in situ. The chloride penetration in situ is …


Hierarchical Life-Cycle Design Of Concrete Structures, Zhujun Wang, Jin Weiliang, Ju Chen Jun 2016

Hierarchical Life-Cycle Design Of Concrete Structures, Zhujun Wang, Jin Weiliang, Ju Chen

International Conference on Durability of Concrete Structures

Concrete structures’ service life lasts decades. In order to deal with all the probable degradations and deteriorations in the whole life span, the concept of concrete structures’ Life-Cycle Design was introduced into China in the 1980s. However, until this day, Life-Cycle Design is still more of a concept to most structure designers and engineers, rather than a practical method. This paper provides a hierarchical method for concrete structures’ Life-Cycle Design, in which the design process is divided into five levels. Safety should be the fundamental requirements for all concrete structures, so as to guarantee a reliable quality. For structures located …


Study Of Water Permeability Of Lightweight Concrete, Xiaoxiao Xu, Haibin Yang, Hongzhi Cui, Zitao Lin, Tommy Yiu Lo Jun 2016

Study Of Water Permeability Of Lightweight Concrete, Xiaoxiao Xu, Haibin Yang, Hongzhi Cui, Zitao Lin, Tommy Yiu Lo

International Conference on Durability of Concrete Structures

The relationship between water permeability and different levels of the tested layers from the top surface to the bottom surface of the lightweight concrete specimens is determined in this study. It is beneficial to develop the design criteria for a durable lightweight concrete. The water permeability coefficient K of the samples was determined by water permeability test using GWT. It is found that the water permeability coefficient K of the three layers in each set of samples tends to decrease as the level of the tested from the top surface increase. Larger Rebound Number and higher density in the bottom …


Influence Of Sio2@Pmhs On The Water Absorption Of Cement Mortar As A Surface Treatment Agent, Ran Li, Pengkun Hou, Zonghui Zhou, Xin Cheng Jun 2016

Influence Of Sio2@Pmhs On The Water Absorption Of Cement Mortar As A Surface Treatment Agent, Ran Li, Pengkun Hou, Zonghui Zhou, Xin Cheng

International Conference on Durability of Concrete Structures

In this paper, the core–shell structured SiO2@PMHS hybrid nanoparticles were synthesized with tetraethoxysilane (TEOS) and polymethylhydrosiloxane (PMHS). And SiO2@PMHS core–shell nanoparticles were first used as a surface treatment agent for cement-based materials. The influence of SiO2@PMHS nanoparticles on the water absorption of hardened cement mortar with water-to-cement ratio of 0.6 was investigated. Results showed that the water absorption of cement mortar treated with SiO2@PMHS nanoparticles was decreased by 93.47% in comparison to the control sample.


Performance Of Concrete Patch Repairs: From A Durability Point Of View, Choorackal Avirachan Eldho, Ominda Nanayakkar, Jun Xia, Steve Jones Jun 2016

Performance Of Concrete Patch Repairs: From A Durability Point Of View, Choorackal Avirachan Eldho, Ominda Nanayakkar, Jun Xia, Steve Jones

International Conference on Durability of Concrete Structures

Chloride contamination in reinforced concrete leads to the corrosion of steel bars. Concrete patch repairs are widely practiced as a remedial measure for the mitigation of such corrosion in reinforced concrete structures. The performance of the patch repairs was studied by various researchers in the past. The structural and material aspects of patch repairs have received more attention than the electrochemical consequences of patch repairs in past studies. But electrochemical changes could be the underlying cause for the failure of many patch repairs. This paper reviews the performance of patch repairs from a durability point of view. It covers the …


Aggregate Shape Effect On Multicomponent Ionic Electromigration In Concrete, Qing-Feng Liu, Long-Yuan Li, Jian Yang Jun 2016

Aggregate Shape Effect On Multicomponent Ionic Electromigration In Concrete, Qing-Feng Liu, Long-Yuan Li, Jian Yang

International Conference on Durability of Concrete Structures

This paper presents a numerical study on the mechanism of chloride migration in concrete. Unlike most of existing work, this study utilises multicomponent ionic transport models to reflect the influence of ionic interactions by coupling both mass conservation and Poisson’s equations. A series of 2-D, 3-phase models with different shapes and volume fractions of aggregates are developed to simulate the chloride migration test. Through a comparatively overall numerical exploration that considers external voltage, ionic interactions, heterogeneous nature, ITZ, and ionic binding, some important features about multispecies coupling and aggregate shape effect, which have not been properly reported from existing concrete …


Effectiveness Of Vacuum Saturation Preconditioning Regime For Assessing Water Permeability Of High Performance Concrete, Kai Yang, Muhammed Basheer, Changhui Yang, Yun Bai, Adrian Long Jun 2016

Effectiveness Of Vacuum Saturation Preconditioning Regime For Assessing Water Permeability Of High Performance Concrete, Kai Yang, Muhammed Basheer, Changhui Yang, Yun Bai, Adrian Long

International Conference on Durability of Concrete Structures

Saturating high performance concrete (HPC) for assessing water permeability is a challenge. This paper reports a testing program established to determine the reliability and efficiency of an in situ preconditioning regime, the vacuum saturation, for the water permeability test. The vacuum saturation regime was examined through changing the parameters used and to justify if the field conditioning regime is able to yield similar results as in the laboratory, the results after vacuum saturation were statistically analysed and compared with that after incremental immersion. Its accuracy was further examined by additional experiments, whereas factors considered include different concrete mixes and different …


Research On Chloride Penetration Resistance Of Hybrid Fiber Reinforced Self-Compacting Concrete, Wu-Jian Long, Zhe-Ming Mai, Jin-Guang Shi, Tian-Tian Zhao, Wu-Lei Peng Jun 2016

Research On Chloride Penetration Resistance Of Hybrid Fiber Reinforced Self-Compacting Concrete, Wu-Jian Long, Zhe-Ming Mai, Jin-Guang Shi, Tian-Tian Zhao, Wu-Lei Peng

International Conference on Durability of Concrete Structures

The properties of chloride penetration of hybrid fiber reinforced self-compacting concrete (SCC) were investigated in this study. The results show that, the chloride penetration resistance of concrete can be improved by single incorporation either carbon or cellulose fibers. The concrete chloride diffusion coefficient DRCM of 12-cm length carbon SCC with fiber content of 1.7 kg/m3, 2.72 kg/m3, and 3.4 kg/m3 decreases by 10.3%, 25.5%, and 18.2% compared to reference concrete without any fibers, respectively. Moreover, the concrete chloride diffusion coefficient DRCM of cellulose SCC with fiber content of 1.2 kg/m3, 1.6 …


Corrosion Of Steel In Concrete And Its Prevention In Aggressive Chloride-Bearing Environments, Luca Bertolini, Maddalena Carsana, Matteo Gastaldi, Federica Lollini, Elena Redaelli Jun 2016

Corrosion Of Steel In Concrete And Its Prevention In Aggressive Chloride-Bearing Environments, Luca Bertolini, Maddalena Carsana, Matteo Gastaldi, Federica Lollini, Elena Redaelli

International Conference on Durability of Concrete Structures

This keynote paper deals with the durability of reinforced concrete (RC) structures exposed to aggressive environments characterized by high concentration of chloride ions, namely, marine environments or the use of de-icing salts. The mechanism of chloride-induced corrosion of steel in concrete is introduced, and its influence on the service life of RC structures is analyzed. Factors affecting the time to corrosion initiation are described with regard to both concrete properties and environmental exposure conditions. Design approaches available for achieving durability targets associated with the design service life are analyzed, focusing on studies carried out by the authors in recent years …


Mat-705: Improving The Efficiency Of Zinc Sacrificial Anodes In Repaired Concrete, Ahmed G. Bediwy, Mohamed T. Bassuoni, Martin Beaudette Jun 2016

Mat-705: Improving The Efficiency Of Zinc Sacrificial Anodes In Repaired Concrete, Ahmed G. Bediwy, Mohamed T. Bassuoni, Martin Beaudette

Canadian Society for Civil Engineering

Zinc sacrificial anodes are considered an effective and economical method to prevent the electrochemical corrosion of steel bars by providing cathodic current to bars, which can provide corrosion protection at low galvanic current densities in the range of 0.2 to 2 mA/m2. Sacrificial anodes are commonly used in RC structures particularly in bridge decks to mitigate a critical phenomenon that occurs in the original concrete beside the repaired patches, which is known as the ‘halo effect’. One of the key factors affecting the efficacy of zinc anodes is the resistivity of concrete or cementitious repair material in which these anodes …


Mat-708: Monitoring The Corrosion Process Of Reinforced Concrete Flat Slab-Column Connection, Mahmoud E. Said, Amgad Hussein, Assem A. A. Hassan Jun 2016

Mat-708: Monitoring The Corrosion Process Of Reinforced Concrete Flat Slab-Column Connection, Mahmoud E. Said, Amgad Hussein, Assem A. A. Hassan

Canadian Society for Civil Engineering

The corrosion of the steel reinforcement embedded in a two-way reinforced concrete flat slab around the column stub area was investigated in this study, which aimed to studying the effect of corrosion on the shear punching behavior. Two square flat slab-column connections were cast, the flat slab dimension was 1900 mm × 1900 mm × 150 mm, and the column dimensions was 250 mm × 250 mm. A specific delaminated area was corroded around the column stub to emphasize the effect of corrosion around punching area. The corrosion reached two levels of mass loss uniformly over that specified area: 0% …


Mat-713: Evaluation Of Ndt Techniques For Concrete Bridge Decks Using Fuzzy Analytical Hierarchy Process, Tarek Omar, Moncef L. Nehdi Jun 2016

Mat-713: Evaluation Of Ndt Techniques For Concrete Bridge Decks Using Fuzzy Analytical Hierarchy Process, Tarek Omar, Moncef L. Nehdi

Canadian Society for Civil Engineering

Considering the colossal backlog of deteriorating bridges, transportation agencies need to systematically evaluate bridge deck conditions in order to optimize the timing, scope, and approach of preventive maintenance, repair, and replacement. Over the last few years, there have been growing interest among bridge infrastructure stakeholders in using non-destructive methodologies for bridge inspection, evaluation, and maintenance. Nondestructive testing (NDT) techniques can provide needed information about the “under-the-surface” deteriorated condition of bridge decks. This paper examines the most common NDT technologies for assessing bridge decks. Each technology was rated based on five performance measures: capability to detect subsurface defects, speed of data …


Mat-714: Condition Assessment And Deterioration Prediction Tools For Concrete Bridges: A New Look, Tarek Omar, Moncef L. Nehdi Jun 2016

Mat-714: Condition Assessment And Deterioration Prediction Tools For Concrete Bridges: A New Look, Tarek Omar, Moncef L. Nehdi

Canadian Society for Civil Engineering

Structural problems created by corrosion, ageing, aggressive environments, material defects and unforeseen mechanical or seismic loads can compromise the serviceability and safety of bridges. The importance of an effective bridge-management system (BMS) cannot be overstated, especially in light of the recent collapse of bridges in North America and elsewhere. Several technologies are available for assessing the condition of concrete bridges and a number of deterioration models are used to predict future bridge conditions and estimate associated funding requirements. This paper critically reviews the different available condition assessment and deterioration prediction approaches for concrete bridges. The potential applications of condition assessment …


Mat-735: Optimizing Performance Of Zinc Coated Reinforcing Steel In Concrete Structures, Martin Gagné, Shannon Pole, Frank Goodwin, Gary Dallin Jun 2016

Mat-735: Optimizing Performance Of Zinc Coated Reinforcing Steel In Concrete Structures, Martin Gagné, Shannon Pole, Frank Goodwin, Gary Dallin

Canadian Society for Civil Engineering

Corrosion of steel reinforcing bar (rebar) is the most significant cause of concrete failure, resulting in expensive repairs and premature structure replacements across the country. This paper will discuss a new, low-cost, zinc coating process for rebar. The properties of this new coated rebar and its contribution to improvement of concrete performance will be presented together with the status of related national and international standards. The Continuous Galvanized Rebar (CGR) coating process is similar to galvanizing of sheet steel. The zinc coating is durable and resistant to abrasion that is routine during transport and construction, but is also highly ductile …


Mat-762: Building Sustainable Continuously Reinforced Concrete Pavement Using Gfrp Bars: Case Study-Highway 40 West-Montreal, Canada, Abdoulaye Sanni B., Hamdy M. Mohamed, Denis Thébeau, Brahim Benmokrane Jun 2016

Mat-762: Building Sustainable Continuously Reinforced Concrete Pavement Using Gfrp Bars: Case Study-Highway 40 West-Montreal, Canada, Abdoulaye Sanni B., Hamdy M. Mohamed, Denis Thébeau, Brahim Benmokrane

Canadian Society for Civil Engineering

Continuously reinforced concrete pavement designs (CRCP) are premium pavement designs that are often used on heavily-trafficked roadways and urban corridors. Although CRCP typically is an effective, long-lasting pavement design, it can develop performance problems when the aggregate-interlock load transfer at the transverse cracks is degraded. The prevalence of wide cracks in CRCP has frequently been associated with ruptured steel and significant levels of corrosion. Because of that, there has been recent interest in identifying new reinforcing materials that can prevent or minimize corrosion-related issues in CRCP. Glass fibre-reinforced polymer (GFRP) bars are one product being investigated for use in CRCP …


Ndm-524: Case Study To Assess The Sensitivity Of Prestressed Concrete Poles To Tornadoes, Ahmed M. Ibrahim, Ashraf A. El Damatty Jun 2016

Ndm-524: Case Study To Assess The Sensitivity Of Prestressed Concrete Poles To Tornadoes, Ahmed M. Ibrahim, Ashraf A. El Damatty

Canadian Society for Civil Engineering

Transmission line structures play a vital role in transmitting electricity from the source of production to the distribution system. The main components of a transmission line are the conductors, the insulator strings, the ground wires and the supporting towers. Among the different types of supporting towers, prestressed concrete transmission poles have the advantages of low installation and maintenance costs, appropriate delivery time, and corrosion resistivity. To the best of the authors’ knowledge, this paper represents the first investigation conducted to assess the response of cantilever prestressed concrete poles to tornadoes. The localized nature of the tornadoes and the extended length …


Ndm-562: Behaviour Of Concrete Columns With Gfrp Circular And Rectilinear Confining Reinforcement, Zahra Kharal, Shamim A. Sheikh Jun 2016

Ndm-562: Behaviour Of Concrete Columns With Gfrp Circular And Rectilinear Confining Reinforcement, Zahra Kharal, Shamim A. Sheikh

Canadian Society for Civil Engineering

Glass Fibre-Reinforced Polymer (GFRP) bars are becoming a feasible alternative to steel bars to produce corrosion- free reinforced concrete structures. In an effort to assess the effectiveness GFRP spirals and GFRP rectilinear ties as internal reinforcement in columns, an extensive research program is underway at the University of Toronto. Fifteen 356 mm diameter full-scale circular columns and sixteen 305 mm x 305 mm cross-section square columns were constructed and tested under simulated earthquake loading. This extended abstract presents an example comparison of the experimental behaviour of circular and square concrete columns with internal reinforcement comprising of steel longitudinal bars and …


Str-824: Fatigue Behavior Of Concrete Underground Chambers Reinforced With Gfrp Bars, Michaël Guérin, Hamdy M. Mohamed, Brahim Benmokrane Jun 2016

Str-824: Fatigue Behavior Of Concrete Underground Chambers Reinforced With Gfrp Bars, Michaël Guérin, Hamdy M. Mohamed, Brahim Benmokrane

Canadian Society for Civil Engineering

Precast underground concrete chambers reinforced with steel bars are used frequently in construction and electrical industry for housing power cables and transformers. In Quebec, more than 30,000 of these chambers have been installed by Hydro-Quebec during the last 30 years. However, like other conventionally reinforced concrete structures, corrosion of steel reinforcement constitutes the major cause of chambers deterioration, leading to costly repairs and rehabilitation as well as a significant reduction in service life. This paper presents experimental data on the fatigue and static behavior of full-scale underground concrete chamber reinforced totally with glass fiber-reinforced polymer (GFRP) bars. The chamber measure …