Open Access. Powered by Scholars. Published by Universities.®

Science and Technology Studies Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Science and Technology Studies

A Comparative Analysis Of Multichannel Data Acquisition Systems For Quality Assurance In External Beam Radiation Therapy, Iolanda Fuduli, Claudiu Porumb, Anthony Espinoza, Abdullah Aldosari, Martin Carolan, Michael Lf Lerch, Peter E. Metcalfe, Anatoly Rosenfeld, Marco Petasecca Jan 2015

A Comparative Analysis Of Multichannel Data Acquisition Systems For Quality Assurance In External Beam Radiation Therapy, Iolanda Fuduli, Claudiu Porumb, Anthony Espinoza, Abdullah Aldosari, Martin Carolan, Michael Lf Lerch, Peter E. Metcalfe, Anatoly Rosenfeld, Marco Petasecca

Anthony A Espinoza Mr

The paper presents a comparative study performed by the Centre of Medical Radiation Physics (CMRP) on three multichannel Data Acquisition Systems (DAQ) based on different analogue front-ends to suit a wide range of radiotherapy applications. The three front-ends are: a charge-to-frequency converter developed by INFN Torino, an electrometer and a charge-to-digital converter (both commercial devices from Texas Instruments). For the first two (named DAQ A and B), the CMRP has designed the read-out systems whilst the third one (DAQ C) comes with its own evaluation board. For the purpose of the characterization DAQ A and DAQ B have been equipped …


Comparative Evaluation Of Modern Dosimetry Techniques Near Low- And High-Density Heterogeneities, Eyad A. Alhakeem, Sami Alshaikh, Anatoly B. Rosenfeld, Sergei F. Zavgorodni Jan 2015

Comparative Evaluation Of Modern Dosimetry Techniques Near Low- And High-Density Heterogeneities, Eyad A. Alhakeem, Sami Alshaikh, Anatoly B. Rosenfeld, Sergei F. Zavgorodni

Faculty of Engineering and Information Sciences - Papers: Part A

The purpose of this study is to compare performance of several dosimetric methods in heterogeneous phantoms irradiated by 6 and 18 MV beams. Monte Carlo (MC) calculations were used, along with two versions of Acuros XB, anisotropic analytical algorithm (AAA), EBT2 film, and MOSkin dosimeters. Percent depth doses (PDD) were calculated and measured in three heterogeneous phantoms. The first two phantoms were a 30 x 30 x 30 cm3 solid-water slab that had an air-gap of 20x 2.5 x 2.35 cm3. The third phantom consisted of 30 x 30 x 5 cm3 solid water slabs, two 30 x 30 x …


The Role Of Pyrimidine And Water As Underlying Molecular Constituents For Describing Radiation Damage In Living Tissue: A Comparative Study, Martina C. Fuss, L Ellis-Gibbings, Darryl B. Jones, M J. Brunger, Francisco Blanco, A Muñoz, Paulo Limao-Vieira, Gustavo Garcia Jan 2015

The Role Of Pyrimidine And Water As Underlying Molecular Constituents For Describing Radiation Damage In Living Tissue: A Comparative Study, Martina C. Fuss, L Ellis-Gibbings, Darryl B. Jones, M J. Brunger, Francisco Blanco, A Muñoz, Paulo Limao-Vieira, Gustavo Garcia

Faculty of Engineering and Information Sciences - Papers: Part A

Water is often used as the medium for characterizing the effects of radiation on living tissue. However, in this study, charged-particle track simulations are employed to quantify the induced physicochemical and potential biological implications when a primary ionising particle with energy 10 keV strikes a medium made up entirely of water or pyrimidine. Note that pyrimidine was chosen as the DNA/RNA bases cytosine, thymine, and uracil can be considered pyrimidine derivatives. This study aims to assess the influence of the choice of medium on the charged-particle transport, and identify how appropriate it is to use water as the default medium …