Open Access. Powered by Scholars. Published by Universities.®
![Digital Commons Network](http://assets.bepress.com/20200205/img/dcn/DCsunburst.png)
Science and Technology Studies Commons™
Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 5 of 5
Full-Text Articles in Science and Technology Studies
Voltage And Power Quality Improvement Strategy For A Dfig Wind Farm During Variable Wind Conditions, L Meegahapola, T Littler, B Fox, J Kennedy, D Flynn
Voltage And Power Quality Improvement Strategy For A Dfig Wind Farm During Variable Wind Conditions, L Meegahapola, T Littler, B Fox, J Kennedy, D Flynn
Dr Lasantha G Meegahapola
This paper presents a voltage and power quality enhancement scheme for a doubly-fed induction generator (DFIG) wind farm during variable wind conditions. The wind profiles were derived considering the measured data at a DFIG wind farm located in Northern Ireland (NI). The aggregated DFIG wind farm model was validated using measured data at a wind farm during variable generation. The voltage control strategy was developed considering the X/R ratio of the wind farm feeder which connects the wind farm and the grid. The performance of the proposed strategy was evaluated for different X/R ratios, and wind profiles with different characteristics. …
Voltage Security Constrained Reactive Power Optimization Incorporating Wind Generation, L G. Meegahapola, E Vittal, A Keane, D Flynn
Voltage Security Constrained Reactive Power Optimization Incorporating Wind Generation, L G. Meegahapola, E Vittal, A Keane, D Flynn
Dr Lasantha G Meegahapola
This paper presents a comparative analysis between conventional optimal power flow (OPF) and voltage constrained OPF strategies with wind generation. The study has been performed using the New England 39 bus system with 12 doublyfed induction generator (DFIG) based wind farms installed across the network. A voltage security assessment is carried out to determine the critical wind farms for voltage stability enhancement. The power losses and individual wind farm reactive power generation have been compared with and without voltage stability constraints imposed on the OPF simulation. It is shown that voltage constrained OPF leads to much greater active power losses …
Capability Curve Based Enhanced Reactive Power Control Strategy For Stability Enhancement And Network Voltage Management, Lasantha Meegahapola, Tim Littler, Sarath Perera
Capability Curve Based Enhanced Reactive Power Control Strategy For Stability Enhancement And Network Voltage Management, Lasantha Meegahapola, Tim Littler, Sarath Perera
Dr Lasantha G Meegahapola
Reactive power has become a vital resource in modern electricity networks due to increased penetration of distributed generation. This paper examines the extended reactive power capability of DFIGs to improve network stability and capability to manage network voltage profile during transient faults and dynamic operating conditions. A coordinated reactive power controller is designed by considering the reactive power capabilities of the rotor-side converter (RSC) and the grid-side converter (GSC) of the DFIG in order to maximise the reactive power support from DFIGs. The study has illustrated that, a significant reactive power contribution can be obtained from partially loaded DFIG wind …
A Multiagent Approach For Decentralized Voltage Regulation In Power Distribution Networks Within Dgs, Fenghui Ren, Minjie Zhang, Danny Sutanto
A Multiagent Approach For Decentralized Voltage Regulation In Power Distribution Networks Within Dgs, Fenghui Ren, Minjie Zhang, Danny Sutanto
Dr Fenghui Ren
Voltage regulation (VR) is a procedure to keep voltages in a distribution network (DN) within normal limits. Conven- tionally, a voltage regulator can read voltage levels from pre- dened measures, and regulate the voltages. However, due to lacking of a distributed generator's (DG) information, the unexpected electricity from a DG will mislead readings on voltages levels, so as to disturb the VR in a DN. Adjust- ing a DG's reactive power output is an alternative way for VR. However, because of limited penetration levels, DGs need to collaborate with other devices in order to provide an eective voltage regulation. Therefore, …
Impact Of Mains Connected Three-Phase Induction Motor Loading Levels On Network Voltage Unbalance Attenuation, Upuli Jayatunga, Sarath Perera, Philip Ciufo
Impact Of Mains Connected Three-Phase Induction Motor Loading Levels On Network Voltage Unbalance Attenuation, Upuli Jayatunga, Sarath Perera, Philip Ciufo
Dr Philip Ciufo
Voltage unbalance (VU) in power systems should be managed in a systematic manner in order to minimise its adverse effects on both customer equipment and supply utilities. It is a well known fact that three-phase induction motor performance can be significantly affected in the presence of supply voltage unbalance. It is also known that three-phase induction motors can help to reduce pre-existing network voltage unbalance levels. Recently undertaken research aligned with IEC/TR 61000-3-13:2008 Technical Report on voltage unbalance management (emission allocation and emission assessment) have quantified the contribution made by induction motors to the net voltage unbalance at a point …