Open Access. Powered by Scholars. Published by Universities.®

Science and Technology Studies Commons

Open Access. Powered by Scholars. Published by Universities.®

None

Dr Lasantha G Meegahapola

Selected Works

Wind

Articles 1 - 6 of 6

Full-Text Articles in Science and Technology Studies

Impact Of Wind Generation Mix On Transient Stability For An Interconnected Power System, Lasantha Meegahapola, Damian Flynn, Jason Kennedy, Tim Littler Dec 2013

Impact Of Wind Generation Mix On Transient Stability For An Interconnected Power System, Lasantha Meegahapola, Damian Flynn, Jason Kennedy, Tim Littler

Dr Lasantha G Meegahapola

The rapid growth of wind generation in many European countries is pushing power systems into uncharted territory. As additional wind generators are installed, the changing generation mix may impact on power system stability. This paper adopts the New England 39 bus system as a test system for transient stability analysis. Thermal generator models are based on a likely future plant mix for existing systems, while varying capacities of fixed-speed induction generators (FSIG) and doubly-fed induction generators (DFIG) are considered. The main emphasis here has been placed on the impact of wind technology mix on inter-area oscillations following transient grid disturbances. …


Optimal Power Flow With Variable Wind Conditions, S Durairaj, L Meegahapola, D Flynn, B Fox Dec 2013

Optimal Power Flow With Variable Wind Conditions, S Durairaj, L Meegahapola, D Flynn, B Fox

Dr Lasantha G Meegahapola

This paper presents simulation studies of an electric arc furnace (EAF) model in the MATLAB/SIMULINK environment. EAF was modeled as a current source controlled by a non-linear resistance. Voltage flicker, a phenomenon of annoying light intensity fluctuation, caused by EAF, has been a major power quality concern for both power companies and customers. A model was developed for the electric arc furnace and it was applied in the simulation studies of distribution static synchronous compensator (DSTATCOM) for voltage flicker mitigation. The controller for DSTATCOM was designed based on DQ-model for the reactive power management which helps in the mitigation of …


Voltage And Power Quality Improvement Strategy For A Dfig Wind Farm During Variable Wind Conditions, L Meegahapola, T Littler, B Fox, J Kennedy, D Flynn Dec 2013

Voltage And Power Quality Improvement Strategy For A Dfig Wind Farm During Variable Wind Conditions, L Meegahapola, T Littler, B Fox, J Kennedy, D Flynn

Dr Lasantha G Meegahapola

This paper presents a voltage and power quality enhancement scheme for a doubly-fed induction generator (DFIG) wind farm during variable wind conditions. The wind profiles were derived considering the measured data at a DFIG wind farm located in Northern Ireland (NI). The aggregated DFIG wind farm model was validated using measured data at a wind farm during variable generation. The voltage control strategy was developed considering the X/R ratio of the wind farm feeder which connects the wind farm and the grid. The performance of the proposed strategy was evaluated for different X/R ratios, and wind profiles with different characteristics. …


Impact On Transient And Frequency Stability For A Power System At Very High Wind Penetration, Lasantha Meegahapola, Damian Flynn Dec 2013

Impact On Transient And Frequency Stability For A Power System At Very High Wind Penetration, Lasantha Meegahapola, Damian Flynn

Dr Lasantha G Meegahapola

This paper analyzes the impact on transient and frequency stability for a power system at very high wind penetration (40% wind). Wind penetration is based on the doubly-fed induction generator (DFIG), and a systematic approach has been adopted for wind power integration. A sensitivity analysis has been carried out for each wind integration scenario and for different wind generator loading conditions. A range of fault locations has been selected for stability analysis based on the proximity to synchronous generation and wind farms. The analysis has shown that transient stability performance is subject to fault location in the network, especially when …


Transient Stability Analysis Of A Power System With High Wind Penetration, Lasantha Meegahapola, Damian Flynn, Tim Littler Dec 2013

Transient Stability Analysis Of A Power System With High Wind Penetration, Lasantha Meegahapola, Damian Flynn, Tim Littler

Dr Lasantha G Meegahapola

This paper presents transient stability analysis for a power system with high wind penetration. The transient stability has been evaluated based on two stability criteria: rotor angle stability and voltage stability. A modified IEEE-14 bus system has been used as the main study network and simulations have been conducted at several wind power penetration levels, defined as a fraction of total system generation. A wide range of scenarios have been presented based on the wind farm voltage at the point of connection, i.e. low voltage (LV) distribution level and high voltage (HV) transmission level, and the type of wind generator …


Active Use Of Dfig Based Wind Farms For Transient Stability Improvement During Grid Disturbances, Lasantha Meegahapola, Damian Flynn, Jason Kennedy, Tim Littler Dec 2013

Active Use Of Dfig Based Wind Farms For Transient Stability Improvement During Grid Disturbances, Lasantha Meegahapola, Damian Flynn, Jason Kennedy, Tim Littler

Dr Lasantha G Meegahapola

The doubly-fed induction generator (DFIG) now represents the dominant technology in wind turbine design. One consequence of this is limited damping and inertial response during transient grid disturbances. A 'decoupled' strategy is therefore proposed to operate the DFIG grid-side converter (GSC) as a static synchronous compensator (STATCOM) during a fault, supporting the local voltage, while the DFIG operates as a fixed-speed induction generator (FSIG) providing an inertial response. The modeling aspects of the decoupled control strategy, the selection of protection control settings, the significance of the fault location and operation at sub- and super-synchronous speeds are analyzed in detail. In …