Impact Of Wind Generator Control Strategies On Flicker Emission In Distribution Networks, Lasantha Meegahapola, Sarath Perera Dec 2013

Impact Of Wind Generator Control Strategies On Flicker Emission In Distribution Networks, Lasantha Meegahapola, Sarath Perera

Dr Lasantha G Meegahapola

Renewable power generators are increasingly being integrated to electricity networks to achieve future renewable energy targets in power generation. In particular, wind power generation has already reported substantial penetration levels in electricity networks. Traditionally, flicker phenomenon is considered to be one of the power quality issues in power distribution networks due to fluctuating consumer loads connected to the network. Large-scale integration of wind power generators may create significant voltage fluctuations in distribution feeders due to stochastic and intermittent nature of the wind resources. This study aims to investigate and characterize the flicker emission under different control strategies for DFIG based …


Comparative Analysis Of Dynamic Line Rating Models And Feasibility To Minimise Energy Losses In Wind Rich Power Networks, Mathew Simms, Lasantha Meegahapola Dec 2013

Comparative Analysis Of Dynamic Line Rating Models And Feasibility To Minimise Energy Losses In Wind Rich Power Networks, Mathew Simms, Lasantha Meegahapola

Dr Lasantha G Meegahapola

Wind power generation has indicated an exponential increase during last two decades and existing transmission network infrastructure is increasingly becoming inadequate to transmit remotely generated wind power to load centres in the network. The dynamic line rating (DLR) is one of the viable solutions to improve the transmission line ampacity during high wind penetration without investing on an additional transmission network. The main objective of this study is to identify the basic differences between two main line rating standards, since transmission network service providers (TNSPs) heavily depend on these two standards when developing their line rating models. Therefore, a parameter …


Flicker Mitigation Strategy For Dfigs During Variable Wind Conditions, Lasantha Meegahapola, Brendan Fox, Damian Flynn Dec 2013

Flicker Mitigation Strategy For Dfigs During Variable Wind Conditions, Lasantha Meegahapola, Brendan Fox, Damian Flynn

Dr Lasantha G Meegahapola

This paper presents a flicker mitigation scheme for the doubly-fed induction generator (DFIG) during variable wind conditions. The flicker mitigation strategy was developed based on the distribution line X/R ratio and the active power deviation from the average active power during variable wind conditions. Flicker emission was analyzed using a flicker meter based on the IEC standards. Both short-term and long-term flicker severities were analyzed during the time period of study. The flicker mitigation strategy was evaluated under different system conditions such as X/R ratio, distribution line length, shortcircuit capacity (SCC), and wind variability. It is shown that the proposed …


Multi-Objective Reactive Power Support From Wind Farms For Network Performance Enhancement, Lasantha Meegahapola, Brendan Fox, Tim Littler, Damian Flynn Dec 2013

Multi-Objective Reactive Power Support From Wind Farms For Network Performance Enhancement, Lasantha Meegahapola, Brendan Fox, Tim Littler, Damian Flynn

Dr Lasantha G Meegahapola

This paper examines the ability of the doubly fed induction generator (DFIG) to deliver multiple reactive power objectives during variable wind conditions. The reactive power requirement is decomposed based on various control objectives (e.g. power factor control, voltage control, loss minimisation, and flicker mitigation) defined around different time frames (i.e. seconds, minutes, and hourly), and the control reference is generated by aggregating the individual reactive power requirement for each control strategy. A novel coordinated controller is implemented for the rotor-side converter and the grid-side converter considering their capability curves and illustrating that it can effectively utilise the aggregated DFIG reactive …


Voltage Security Constrained Reactive Power Optimization Incorporating Wind Generation, L G. Meegahapola, E Vittal, A Keane, D Flynn Dec 2013

Voltage Security Constrained Reactive Power Optimization Incorporating Wind Generation, L G. Meegahapola, E Vittal, A Keane, D Flynn

Dr Lasantha G Meegahapola

This paper presents a comparative analysis between conventional optimal power flow (OPF) and voltage constrained OPF strategies with wind generation. The study has been performed using the New England 39 bus system with 12 doublyfed induction generator (DFIG) based wind farms installed across the network. A voltage security assessment is carried out to determine the critical wind farms for voltage stability enhancement. The power losses and individual wind farm reactive power generation have been compared with and without voltage stability constraints imposed on the OPF simulation. It is shown that voltage constrained OPF leads to much greater active power losses …