Open Access. Powered by Scholars. Published by Universities.®

Science and Technology Studies Commons

Open Access. Powered by Scholars. Published by Universities.®

Engineering

Selected Works

Voltage

Articles 1 - 13 of 13

Full-Text Articles in Science and Technology Studies

Novel Modulation And Control Strategy For Five-Level Anpc Converter With Unbalanced Dc Voltage Applied To A Single-Phase Grid Connected Pv System, Hamid R. Teymour, Danny Sutanto, Kashem M. Muttaqi, Phil Ciufo Apr 2015

Novel Modulation And Control Strategy For Five-Level Anpc Converter With Unbalanced Dc Voltage Applied To A Single-Phase Grid Connected Pv System, Hamid R. Teymour, Danny Sutanto, Kashem M. Muttaqi, Phil Ciufo

Dr Philip Ciufo

This paper proposes a new control strategy and a novel modulation technique for a grid-connected photo-voltaic (PV) system using a single-phase five-level flying capacitor (FC) based active-neutral-point-clamped (ANPC) converter. The proposed modulator can control the FC voltage to follow the requested reference value and simultaneously generate the required ac output voltage regardless of the values of the dc capacitor voltages of the converter. By implementing this method, smaller values of dc-link and flying capacitors can be used even in applications that could experience ripple or transient in the capacitors voltage. In the grid-connected single-phase five-level ANPC, where the capacitors can …


A Review Of Recent Investigations On Voltage Unbalance Management: Further Contributions To Improvement Of Iec/Tr 61000-3-13:2008, Jayatunga Vitharanage Upuli Priyadarshani Jayatunga, Sarath Perera, Philip Ciufo, Ashish Agalgaonkar Apr 2015

A Review Of Recent Investigations On Voltage Unbalance Management: Further Contributions To Improvement Of Iec/Tr 61000-3-13:2008, Jayatunga Vitharanage Upuli Priyadarshani Jayatunga, Sarath Perera, Philip Ciufo, Ashish Agalgaonkar

Dr Philip Ciufo

Voltage unbalance (VU) management in power systems essentially involves two major aspects: VU emission allocation at the pre-connection stage and compliance assessment at the post-connection stage of installations. This is a summary and a review paper on the recent investigations completed in relation to VU emission assessment techniques which provide further contributions to the improvement of IEC Technical Report IEC/TR61000-3-13:2008. Generalised approaches developed for the classification of different sources of unbalance at the point of evaluation (covering both radial and interconnected networks) and the evaluation of their individual contributions giving emphasis to the discrimination between customer and network responsibility on …


Performance Of Adjustable Speed Drives Subject To Regular Voltage Fluctuations, Kun Zhao, Philip Ciufo, Sarath Perera Apr 2015

Performance Of Adjustable Speed Drives Subject To Regular Voltage Fluctuations, Kun Zhao, Philip Ciufo, Sarath Perera

Dr Philip Ciufo

The impact of power quality disturbances on customer equipment has been a topic of interest to equipment manufacturers, electricity utilities, customers and to those involved in the development of electromagnetic compatibility standards. Recently, a new interest has developed in the possible impact of voltage fluctuations on customer equipment because of suggestions to relax voltage fluctuation limits and hence the flicker limits in power systems. With a view to contribute to this understanding, this paper investigates the performance of an adjustable speed drive (ASD) when subjected to sinusoidal regular voltage fluctuations. When the ASD is operating in open loop mode, the …


A Sensitivity Analysis Toolkit For The Simplification Of Mv Distribution Network Voltage Management, Fabian Tamp, Philip Ciufo Apr 2015

A Sensitivity Analysis Toolkit For The Simplification Of Mv Distribution Network Voltage Management, Fabian Tamp, Philip Ciufo

Dr Philip Ciufo

As distribution networks become increasingly variable and generation becomes increasingly decentralised, voltage standards are becoming more liable to violation. Accordingly, intelligent voltage management strategies are required to enable standards compliance without unduly increasing network maintenance or infrastructure costs. The relationship between network power and voltages, however, is complex, non-linear and interdependent, and thus is difficult to conceptualise and use for decision-making and control purposes. This paper introduces a software toolkit that simplifies the development of voltage management strategies by the application of sensitivity analysis. Sensitivity analysis reduces complex network relationships to simple linear equations, and thus enables easy and comprehensive …


Voltage Unbalance Emission Assessment: Sources Of Contribution And Their Ranking, U Jayatunga, Sarath Perera, P Ciufo, A P. Agalgaonkar Apr 2015

Voltage Unbalance Emission Assessment: Sources Of Contribution And Their Ranking, U Jayatunga, Sarath Perera, P Ciufo, A P. Agalgaonkar

Dr Philip Ciufo

etermining sources of voltage unbalance (VU) and quantifying their individual contributions in an interconnected network is a complex task due to multiple interactions that take place between them. Post-connection VU emission assessment techniques in relation to customer installations are important not only in compliance assessment according to IEC/TR 61000-3- 13:2008 Limits - Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems, but also in determining the various emission contributors in the power system being considered. This paper presents a case study on the application of a recently developed post-connection VU emission assessment …


Point Of Common Coupling (Pcc) Voltage Control Of A Grid-Connected Solar Photovoltaic (Pv) System, Brian K. Perera, Philip Ciufo, Sarath Perera Apr 2015

Point Of Common Coupling (Pcc) Voltage Control Of A Grid-Connected Solar Photovoltaic (Pv) System, Brian K. Perera, Philip Ciufo, Sarath Perera

Dr Philip Ciufo

In future low voltage grids, with multiple inverter interfaced sources connected, voltage regulation may become a necessary task. The potential exists for inverter interfaced sources to be deployed to regulate the voltage at the point of common coupling (PCC) of each inverter interfaced sources. The PCC voltage regulation is attainable with inverter interfaced sources by dynamically controlling the amount of reactive power injected to the power distribution grid by individual systems. In the current research, a closed-loop controller is proposed to regulate the PCC voltage of a solar photovoltaic (PV) system that is connected to a single-phase power distribution feeder …


Over-Voltage Mitigation Within Distribution Networks With A High Renewable Distributed Generation Penetration, Joel Kennedy, Philip Ciufo, Ashish Agalgaonkar Apr 2015

Over-Voltage Mitigation Within Distribution Networks With A High Renewable Distributed Generation Penetration, Joel Kennedy, Philip Ciufo, Ashish Agalgaonkar

Dr Philip Ciufo

The rapid growth of grid-connected distributed generation has increased the likelihood of over-voltage occurrences in distribution networks. In recent times, much research has taken place in order to develop a control strategy to mitigate the voltage rise problem. However, most of the published strategies require re-tuning when additional resources are connected, or have a strong dependence on network parameters, such as fault level. This paper proposes a novel over-voltage mitigation scheme that has many advantages not observed in literature. Firstly, the control scheme can integrate with an existing feeder in a plug-and-play fashion. No prior analysis is necessary to configure …


Rectifier Capacitor Filter Stress Analysis When Subject To Regular Voltage Fluctuations, Kun Zhao, Phil Ciufo, Sarath Perera Jan 2014

Rectifier Capacitor Filter Stress Analysis When Subject To Regular Voltage Fluctuations, Kun Zhao, Phil Ciufo, Sarath Perera

Dr Philip Ciufo

Lamp flicker levels which arise as a result of voltage fluctuations can exceed limits set by appropriate standards. New lamp types such as compact fluorescent lights (CFLs) are less sensitive to voltage fluctuations as their flicker characteristics are considerably different compared to those of the traditional incandescent lamp. These differences could support the moderation of the present voltage fluctuation and flicker standards and hence the associated limits. The potential detrimental effects on electrical equipment which may be caused by relaxation of these limits should be investigated before any changes to the present standards take place. The impact of voltage fluctuations …


Voltage And Power Quality Improvement Strategy For A Dfig Wind Farm During Variable Wind Conditions, L Meegahapola, T Littler, B Fox, J Kennedy, D Flynn Dec 2013

Voltage And Power Quality Improvement Strategy For A Dfig Wind Farm During Variable Wind Conditions, L Meegahapola, T Littler, B Fox, J Kennedy, D Flynn

Dr Lasantha G Meegahapola

This paper presents a voltage and power quality enhancement scheme for a doubly-fed induction generator (DFIG) wind farm during variable wind conditions. The wind profiles were derived considering the measured data at a DFIG wind farm located in Northern Ireland (NI). The aggregated DFIG wind farm model was validated using measured data at a wind farm during variable generation. The voltage control strategy was developed considering the X/R ratio of the wind farm feeder which connects the wind farm and the grid. The performance of the proposed strategy was evaluated for different X/R ratios, and wind profiles with different characteristics. …


Voltage Security Constrained Reactive Power Optimization Incorporating Wind Generation, L G. Meegahapola, E Vittal, A Keane, D Flynn Dec 2013

Voltage Security Constrained Reactive Power Optimization Incorporating Wind Generation, L G. Meegahapola, E Vittal, A Keane, D Flynn

Dr Lasantha G Meegahapola

This paper presents a comparative analysis between conventional optimal power flow (OPF) and voltage constrained OPF strategies with wind generation. The study has been performed using the New England 39 bus system with 12 doublyfed induction generator (DFIG) based wind farms installed across the network. A voltage security assessment is carried out to determine the critical wind farms for voltage stability enhancement. The power losses and individual wind farm reactive power generation have been compared with and without voltage stability constraints imposed on the OPF simulation. It is shown that voltage constrained OPF leads to much greater active power losses …


Capability Curve Based Enhanced Reactive Power Control Strategy For Stability Enhancement And Network Voltage Management, Lasantha Meegahapola, Tim Littler, Sarath Perera Dec 2013

Capability Curve Based Enhanced Reactive Power Control Strategy For Stability Enhancement And Network Voltage Management, Lasantha Meegahapola, Tim Littler, Sarath Perera

Dr Lasantha G Meegahapola

Reactive power has become a vital resource in modern electricity networks due to increased penetration of distributed generation. This paper examines the extended reactive power capability of DFIGs to improve network stability and capability to manage network voltage profile during transient faults and dynamic operating conditions. A coordinated reactive power controller is designed by considering the reactive power capabilities of the rotor-side converter (RSC) and the grid-side converter (GSC) of the DFIG in order to maximise the reactive power support from DFIGs. The study has illustrated that, a significant reactive power contribution can be obtained from partially loaded DFIG wind …


A Multiagent Approach For Decentralized Voltage Regulation In Power Distribution Networks Within Dgs, Fenghui Ren, Minjie Zhang, Danny Sutanto Oct 2013

A Multiagent Approach For Decentralized Voltage Regulation In Power Distribution Networks Within Dgs, Fenghui Ren, Minjie Zhang, Danny Sutanto

Dr Fenghui Ren

Voltage regulation (VR) is a procedure to keep voltages in a distribution network (DN) within normal limits. Conven- tionally, a voltage regulator can read voltage levels from pre- dened measures, and regulate the voltages. However, due to lacking of a distributed generator's (DG) information, the unexpected electricity from a DG will mislead readings on voltages levels, so as to disturb the VR in a DN. Adjust- ing a DG's reactive power output is an alternative way for VR. However, because of limited penetration levels, DGs need to collaborate with other devices in order to provide an eective voltage regulation. Therefore, …


Impact Of Mains Connected Three-Phase Induction Motor Loading Levels On Network Voltage Unbalance Attenuation, Upuli Jayatunga, Sarath Perera, Philip Ciufo Feb 2013

Impact Of Mains Connected Three-Phase Induction Motor Loading Levels On Network Voltage Unbalance Attenuation, Upuli Jayatunga, Sarath Perera, Philip Ciufo

Dr Philip Ciufo

Voltage unbalance (VU) in power systems should be managed in a systematic manner in order to minimise its adverse effects on both customer equipment and supply utilities. It is a well known fact that three-phase induction motor performance can be significantly affected in the presence of supply voltage unbalance. It is also known that three-phase induction motors can help to reduce pre-existing network voltage unbalance levels. Recently undertaken research aligned with IEC/TR 61000-3-13:2008 Technical Report on voltage unbalance management (emission allocation and emission assessment) have quantified the contribution made by induction motors to the net voltage unbalance at a point …