Open Access. Powered by Scholars. Published by Universities.®

Science and Technology Studies Commons

Open Access. Powered by Scholars. Published by Universities.®

Engineering

Selected Works

2015

Quality

Articles 1 - 4 of 4

Full-Text Articles in Science and Technology Studies

Characteristics Of Power Quality Disturbance Levels In Australia, Sean Elphick, Vic Smith, Vic Gosbell, Robert Barr Dec 2015

Characteristics Of Power Quality Disturbance Levels In Australia, Sean Elphick, Vic Smith, Vic Gosbell, Robert Barr

Robert Barr

The Australian Long Term Power Quality Survey (LTNPQS) now covers 2,000 sites with a range of different characteristics including strength (related to fault level), line construction and dominant load type. This paper details the latest outcomes of the LTNPQS project in terms of both disturbance levels and reporting methods. A comparison of the differences between voltage, unbalance and harmonic THD levels at strong (close to transformer) and weak (towards the end of LV feeders) sites has been performed and significant differences have been found. A multivariable linear regression study has been undertaken in order to investigate the correlation between site …


Power Quality Emission Assessment Of Photovoltaic Inverters Based On Iec Technical Report 61000-3-15:2011, Devinda Perera, Philip Ciufo, Lasantha G. Meegahapola, Sarath Perera Apr 2015

Power Quality Emission Assessment Of Photovoltaic Inverters Based On Iec Technical Report 61000-3-15:2011, Devinda Perera, Philip Ciufo, Lasantha G. Meegahapola, Sarath Perera

Dr Philip Ciufo

The International Electrotechnical Committee Technical Report IEC 61000-3-15:2011 provides electromagnetic compatibility requirements and test conditions for distributed generators up to 75 A per phase. In the current research, two commercially available photovoltaic (PV) inverters up to the capacity of 3600 W were tested following the guidelines proposed in IEC 61000-3-15 in relation to low order harmonic emission and flicker emission. In addition, the harmonic and flicker emission behaviour of the PV inverters were investigated under varying irradiation conditions. Both PV inverters were observed to comply with the emission requirements prescribed by the technical report under most conditions except for even …


A Comparative Analysis Of Multichannel Data Acquisition Systems For Quality Assurance In External Beam Radiation Therapy, Iolanda Fuduli, Claudiu Porumb, Anthony Espinoza, Abdullah Aldosari, Martin Carolan, Michael Lf Lerch, Peter E. Metcalfe, Anatoly Rosenfeld, Marco Petasecca Jan 2015

A Comparative Analysis Of Multichannel Data Acquisition Systems For Quality Assurance In External Beam Radiation Therapy, Iolanda Fuduli, Claudiu Porumb, Anthony Espinoza, Abdullah Aldosari, Martin Carolan, Michael Lf Lerch, Peter E. Metcalfe, Anatoly Rosenfeld, Marco Petasecca

Anthony A Espinoza Mr

The paper presents a comparative study performed by the Centre of Medical Radiation Physics (CMRP) on three multichannel Data Acquisition Systems (DAQ) based on different analogue front-ends to suit a wide range of radiotherapy applications. The three front-ends are: a charge-to-frequency converter developed by INFN Torino, an electrometer and a charge-to-digital converter (both commercial devices from Texas Instruments). For the first two (named DAQ A and B), the CMRP has designed the read-out systems whilst the third one (DAQ C) comes with its own evaluation board. For the purpose of the characterization DAQ A and DAQ B have been equipped …


The Feasibility Study And Characterziation Of A Two-Dimensional Diode Array In “Magic Phantom” For High Dose Rate Brachytherapy Quality Assurance, A Espinoza, B Beeksma, M Petasecca, I Fuduli, C Porumb, D L. Cutajar, S Corde, M A. Jackson, M Lf Lerch, Anatoly B. Rosenfeld Jan 2015

The Feasibility Study And Characterziation Of A Two-Dimensional Diode Array In “Magic Phantom” For High Dose Rate Brachytherapy Quality Assurance, A Espinoza, B Beeksma, M Petasecca, I Fuduli, C Porumb, D L. Cutajar, S Corde, M A. Jackson, M Lf Lerch, Anatoly B. Rosenfeld

Anthony A Espinoza Mr

High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly 192Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 uGy m2/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the …