Flicker Mitigation Strategy For Dfigs During Variable Wind Conditions, Lasantha Meegahapola, Brendan Fox, Damian Flynn Dec 2013

Flicker Mitigation Strategy For Dfigs During Variable Wind Conditions, Lasantha Meegahapola, Brendan Fox, Damian Flynn

Dr Lasantha G Meegahapola

This paper presents a flicker mitigation scheme for the doubly-fed induction generator (DFIG) during variable wind conditions. The flicker mitigation strategy was developed based on the distribution line X/R ratio and the active power deviation from the average active power during variable wind conditions. Flicker emission was analyzed using a flicker meter based on the IEC standards. Both short-term and long-term flicker severities were analyzed during the time period of study. The flicker mitigation strategy was evaluated under different system conditions such as X/R ratio, distribution line length, shortcircuit capacity (SCC), and wind variability. It is shown that the proposed …


Voltage And Power Quality Improvement Strategy For A Dfig Wind Farm During Variable Wind Conditions, L Meegahapola, T Littler, B Fox, J Kennedy, D Flynn Dec 2013

Voltage And Power Quality Improvement Strategy For A Dfig Wind Farm During Variable Wind Conditions, L Meegahapola, T Littler, B Fox, J Kennedy, D Flynn

Dr Lasantha G Meegahapola

This paper presents a voltage and power quality enhancement scheme for a doubly-fed induction generator (DFIG) wind farm during variable wind conditions. The wind profiles were derived considering the measured data at a DFIG wind farm located in Northern Ireland (NI). The aggregated DFIG wind farm model was validated using measured data at a wind farm during variable generation. The voltage control strategy was developed considering the X/R ratio of the wind farm feeder which connects the wind farm and the grid. The performance of the proposed strategy was evaluated for different X/R ratios, and wind profiles with different characteristics. …


Active Use Of Dfig Based Wind Farms For Transient Stability Improvement During Grid Disturbances, Lasantha Meegahapola, Damian Flynn, Jason Kennedy, Tim Littler Dec 2013

Active Use Of Dfig Based Wind Farms For Transient Stability Improvement During Grid Disturbances, Lasantha Meegahapola, Damian Flynn, Jason Kennedy, Tim Littler

Dr Lasantha G Meegahapola

The doubly-fed induction generator (DFIG) now represents the dominant technology in wind turbine design. One consequence of this is limited damping and inertial response during transient grid disturbances. A 'decoupled' strategy is therefore proposed to operate the DFIG grid-side converter (GSC) as a static synchronous compensator (STATCOM) during a fault, supporting the local voltage, while the DFIG operates as a fixed-speed induction generator (FSIG) providing an inertial response. The modeling aspects of the decoupled control strategy, the selection of protection control settings, the significance of the fault location and operation at sub- and super-synchronous speeds are analyzed in detail. In …


Optimization Of Frt Active Power Performance Of A Dfig During Transient Grid Faults, L Meegahapola, Damian Flynn, Tim Littler Dec 2013

Optimization Of Frt Active Power Performance Of A Dfig During Transient Grid Faults, L Meegahapola, Damian Flynn, Tim Littler

Dr Lasantha G Meegahapola

Optimal fault ride-through (FRT) conditions for a doubly-fed induction generator (DFIG) during a transient grid fault are analyzed with special emphasis on improving the active power generation profile. The transition states due to crowbar activation during transient faults are investigated to exploit the maximum power during the fault and post-fault period. It has been identified that operating slip, severity of fault and crowbar resistance have a direct impact on the power capability of a DFIG, and crowbar resistance can be chosen to optimize the power capability. It has been further shown that an extended crowbar period can deliver enhanced inertial …