Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Physics

Electrically Induced Plasma, Nate Ashby Nov 2015

Electrically Induced Plasma, Nate Ashby

Physics Capstone Projects

My research project, under the mentorship of research professor Ajay Singh was to prove that the plasma he was creating was lasting longer than the electrical current data indicated. He decided that if the plasma was still there, it would be producing light. So we set out to prove that the light emitted from his plasma lasted longer than the current draw measurements.


Kinetic Modeling Of Roll To Roll Rfcvd Plasma, Kudzo S. Ahegbebu, Siva Sashank Tholeti, Alina A. Alexeenko Aug 2015

Kinetic Modeling Of Roll To Roll Rfcvd Plasma, Kudzo S. Ahegbebu, Siva Sashank Tholeti, Alina A. Alexeenko

The Summer Undergraduate Research Fellowship (SURF) Symposium

Roll-to-roll radio frequency plasma enhanced chemical vapor deposition (R2R RFCVD) is a technique for large-scale synthesis of high quality graphitic nanopetals. Graphitic nanopetals are petal-like graphene structures with remarkable electrical and mechanical properties with major industrial applications such as microsupercapacitors. RFCVD uses a non-equilibrium plasma with high energy electrons to catalyze chemical reactions, induce the creation of free radicals, and promote otherwise high temperature chemistry in a low temperature environment. Understanding how bulk plasma characteristics (particularly, power and number densities) vary with changing reactor parameters is an important step towards optimizing synthesis techniques. In our present work we use the …


Langmuir Probes In A Microwave Generated Plasma, Wesley Rawlins Apr 2015

Langmuir Probes In A Microwave Generated Plasma, Wesley Rawlins

Physics Capstone Projects

In this work, we considered a microwave generated plasma, in a toroidal device. In this set up, we tend to meet the conditions for several known plasma instabilities. Not all the gas in the chamber was ionized. Using a Langmuir probe we were able to determine the population temperature and the plasma density in the chamber. The existence of a plasma was determined by measuring the strength of reflected microwaves. We varied the fill pressure in the chamber, as well as the strength of an externally imposed magnetic field. From this, we determined that the plasma temperature decreased with an …


“Ultra Cold” Room Temperature Plasma, Stephen Rupper, Dr. Scott Bergeson Apr 2015

“Ultra Cold” Room Temperature Plasma, Stephen Rupper, Dr. Scott Bergeson

Journal of Undergraduate Research

Many scientists throughout the world are currently doing research on ultra cold neutral plasmas (UCNP). These plasmas are difficult to make and require quite a sophisticated setup. A method that we employ in our lab requires multiple laser pulses to be timed perfectly and aligned precisely in order to ionize the atoms. It also requires the use of a magneto optical trap, which traps the atoms before they are ionized. This setup is very time consuming to build and maintain but we have a mathematical model for it. Since the current methods of creating ultra cold plasmas are hard to …


Experiment And Results On Plasma Etching Of Srf Cavities, J. Upadhyay, Do Im, J. Peshl, S. Popovic, L. Vuskovic, A. -M. Valente-Feliciano, L. Phillips Jan 2015

Experiment And Results On Plasma Etching Of Srf Cavities, J. Upadhyay, Do Im, J. Peshl, S. Popovic, L. Vuskovic, A. -M. Valente-Feliciano, L. Phillips

Physics Faculty Publications

The inner surfaces of SRF cavities are currently chemically treated (etched or electro polished) to achieve the state of the art RF performance. We designed an apparatus and developed a method for plasma etching of the inner surface for SRF cavities. The process parameters (pressure, power, gas concentration, diameter and shape of the inner electrode, temperature and positive dc bias at inner electrode) are optimized for cylindrical geometry. The etch rate non-uniformity has been overcome by simultaneous translation of the gas point-of-entry and the inner electrode during the processing. A single cell SRF cavity has been centrifugally barrel polished, chemically …


Effects Of Plasma Processing On Secondary Electron Yield Of Niobium Samples, M. Basovic, S. Popovic, M. Tomovic, L. Vuskovic, A. Samolov, F. Cuckov Jan 2015

Effects Of Plasma Processing On Secondary Electron Yield Of Niobium Samples, M. Basovic, S. Popovic, M. Tomovic, L. Vuskovic, A. Samolov, F. Cuckov

Physics Faculty Publications

Impurities deposited on the surface of Nb during both the forming and welding of accelerator cavities add to the imperfections of the sheet metal, which then affects the overall performance of the cavities. This leads to a drop in the Q factor and limits the maximum acceleration gradient achievable per unit length of the cavities. The performance can be improved either by adjusting the fabrication and preparation parameters, or by mitigating the effects of fabrication and preparation techniques used. We have developed the experimental setup to determine Secondary Electron Yield (SEY) from the surface of Nb samples. Our aim is …


Construction And Optimization Of A Tapered Amplifier System For Applications In Ultra-Cold Plasma Research, Ryan Cole Jan 2015

Construction And Optimization Of A Tapered Amplifier System For Applications In Ultra-Cold Plasma Research, Ryan Cole

Honors Theses

The number density of cold atoms confined in a magneto-optical trap (MOT) is critically dependent on the intensity of the lasers used to cool the sample. To generate large optical powers while retaining the practicality of homemade external cavity diode lasers (ECDLs), a tapered amplifier (TA) system was designed and constructed to amplify the output of an existing 780 nm, continuous-wave ECDL. The amplifier’s performance is discussed in terms of its gain and power output. Under standard operating conditions, optical amplification of 12 dB is achieved, with a maximum power output of 0.75 W. The completed amplifier is installed into …


Unmatter Plasma Discovered, Florentin Smarandache Jan 2015

Unmatter Plasma Discovered, Florentin Smarandache

Branch Mathematics and Statistics Faculty and Staff Publications

The electron-positron beam plasma was generated in the laboratory in the beginning of 2015. This experimental fact shows that unmatter, a new form of matter that is formed by matter and antimatter bind together (mathematically predicted a decade ago) really exists. That is the electron-positron plasma experiment of 2015 is the experimentum crucis verifying the mathematically predicted unmatter.


Using Higher Ionization States To Increase Coulomb Coupling In An Ultracold Neutral Plasma, M. Lyon, Scott D. Bergeson, A. Diaw, M. S. Murillo Jan 2015

Using Higher Ionization States To Increase Coulomb Coupling In An Ultracold Neutral Plasma, M. Lyon, Scott D. Bergeson, A. Diaw, M. S. Murillo

Faculty Publications

We report measurements and simulations of the time-evolving rms velocity distribution in an ultracold neutral plasma. A strongly coupled ultracold neutral Ca+ plasma is generated by photoionizing laser-cooled atoms close to threshold. A fraction of these ions is then promoted to the second ionization state to form a mixed Ca+-Ca2+ plasma. By varying the time delay between the first and the second ionization events, a minimum in ion heating is achieved. We show that the Coulomb strong-coupling parameter Γ increases by a factor of 1.4 to a maximum value of 3.6. A pure Ca2+ plasma …