Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 6 of 6

Full-Text Articles in Physics

Generating Electromagnetic Nonuniformly Correlated Beams, Milo W. Hyde Iv, Xifeng Xiao, David G. Voelz Dec 2019

Generating Electromagnetic Nonuniformly Correlated Beams, Milo W. Hyde Iv, Xifeng Xiao, David G. Voelz

Faculty Publications

We develop a method to generate electromagnetic nonuniformly correlated (ENUC) sources from vector Gaussian Schell-model (GSM) beams. Having spatially varying correlation properties, ENUC sources are more difficult to synthesize than their Schell-model counterparts (which can be generated by filtering circular complex Gaussian random numbers) and, in past work, have only been realized using Cholesky decomposition—a computationally intensive procedure. Here we transform electromagnetic GSM field instances directly into ENUC instances, thereby avoiding computing Cholesky factors resulting in significant savings in time and computing resources. We validate our method by generating (via simulation) an ENUC beam with desired parameters. We find the …


Effect Of Ar(3p54p; 2p)+M -> Ar(3p54s; 1s)+M Branching Ratio On Optically Pumped Rare Gas Laser Performance, Daniel J. Emmons Ii, David E. Weeks Nov 2019

Effect Of Ar(3p54p; 2p)+M -> Ar(3p54s; 1s)+M Branching Ratio On Optically Pumped Rare Gas Laser Performance, Daniel J. Emmons Ii, David E. Weeks

Faculty Publications

Optically pumped rare gas laser performance is analyzed as a function of the Ar(3p54p; 2p) + M → Ar(3p54s; 1s) + M branching ratios. Due to the uncertainty in the branching ratios, a sensitivity study is performed to determine the effect on output and absorbed pump laser intensities. The analysis is performed using a radio frequency dielectric barrier discharge as the source of metastable production for a variety of Argon in Helium mixtures over pressures ranging from 200 to 500 Torr. Peak output laser intensities show a factor of 7 increase as the branching ratio is …


Measurement Of Electron Density And Temperature From Laser-Induced Nitrogen Plasma At Elevated Pressure (1–6 Bar), Ashwin P. Rao [*], Mark Gragston, Anil K. Patnaik, Paul S. Hsu, Michael B. Shattan Nov 2019

Measurement Of Electron Density And Temperature From Laser-Induced Nitrogen Plasma At Elevated Pressure (1–6 Bar), Ashwin P. Rao [*], Mark Gragston, Anil K. Patnaik, Paul S. Hsu, Michael B. Shattan

Faculty Publications

Laser-induced plasmas experience Stark broadening and shifts of spectral lines carrying spectral signatures of plasma properties. In this paper, we report time-resolved Stark broadening measurements of a nitrogen triplet emission line at 1–6 bar ambient pressure in a pure nitrogen cell. Electron densities are calculated using the Stark broadening for different pressure conditions, which are shown to linearly increase with pressure. Additionally, using a Boltzmann fit for the triplet, the electron temperature is calculated and shown to decrease with increasing pressure. The rate of plasma cooling is observed to increase with pressure. The reported Stark broadening based plasma diagnostics in …


Plasma Spectroscopy Of Titanium Monoxide For Characterization Of Laser Ablation, Todd A. Van Woerkom, Glen P. Perram, Christian G. Parigger, Brian D. Dolasinski, Charles D. Phelps, Patrick A. Berry Aug 2019

Plasma Spectroscopy Of Titanium Monoxide For Characterization Of Laser Ablation, Todd A. Van Woerkom, Glen P. Perram, Christian G. Parigger, Brian D. Dolasinski, Charles D. Phelps, Patrick A. Berry

Faculty Publications

Ablation of titanium wafers in air is accomplished with 60 µs pulsed, 2.94 µm laser radiation. Titanium monoxide spectra are measured in the wavelength range of 500 nm to 750 nm, and molecular signatures include bands of the C3 Δ → X3 Δ α, B3 Π → X3 Δ γ', and A3 Φ → X3 Δ γ transitions. The spatially and temporally averaged spectra appear to be in qualitative agreement with previous temporally resolved studies that employed shorter wavelengths and shorter pulse durations than utilized in this work. The background signals in the current study are possibly due to particulate …


Experimental Study: Underwater Propagation Of Super-Gaussian And Multi-Gaussian Schell-Model Partially Coherent Beams With Varying Degrees Of Spatial Coherence, Svetlana Avramov-Zamurovic, Charles L. Nelson, Milo W. Hyde Iv Feb 2019

Experimental Study: Underwater Propagation Of Super-Gaussian And Multi-Gaussian Schell-Model Partially Coherent Beams With Varying Degrees Of Spatial Coherence, Svetlana Avramov-Zamurovic, Charles L. Nelson, Milo W. Hyde Iv

Faculty Publications

We report on experiments where super-Gaussian and flat-top, multi-Gaussian Schell-model spatially partially coherent beams, with varying degrees of spatial coherence, were propagated underwater. Two scenarios were explored—calm and mechanically agitated water. The main objective of our study was the experimental comparison of the scintillation statistics. For a similar degree of coherence widths, the results show a potentially improved performance of scintillation index for the multi-Gaussian Schell-model beams as compared to the super-Gaussian beams. It should be noted that the presented results pertain only to the given experimental scenarios and further investigation is necessary to determine the scope of the findings.


Laser-Induced Plasma Analysis For Surrogate Nuclear Debris, Michael B. Shattan, John Auxier, A. C. Stowe, Christian G. Parigger Jan 2019

Laser-Induced Plasma Analysis For Surrogate Nuclear Debris, Michael B. Shattan, John Auxier, A. C. Stowe, Christian G. Parigger

Faculty Publications

This work identifies analytical lines in laser-induced plasma for chemical analyses of major elements found in surrogate nuclear debris. These lines are evaluated for interferences and signal strength to insure they would be useful to measure relative concentrations. Compact, portable instruments are employed and can be included as part of a mobile nuclear forensics laboratory for field screening of nuclear debris and contamination. The average plasma temperature is measured using the well-established Boltzmann plot technique, and plasma's average electron density is determined using empirical formulae based on Stark broadening of the H-alpha line. These measurements suggest existence of partial local …