Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Physics

Characterization Of Inert Gas Rf Plasma-Treated Indium Tin Oxide Thin Films Deposited Via Pulsed Dc Magnetron Sputtering, Amber Nicole Reed Jan 2008

Characterization Of Inert Gas Rf Plasma-Treated Indium Tin Oxide Thin Films Deposited Via Pulsed Dc Magnetron Sputtering, Amber Nicole Reed

Browse all Theses and Dissertations

In this work, the effects of a post-deposition RF plasma treatment on indium tin oxide (ITO) thin films prepared with pulsed DC magnetron sputtering in argon were investigated. The parameters of the post-deposition were studied to determine what RF power and gas pressure resulted in the greatest reduction in resistivity in the films while producing the smallest increase in substrate temperature for treatments with both argon and oxygen plasmas. The as-deposited (untreated) films and the treated films were characterized using Raman spectroscopy and X-ray diffraction to determine the effects of the post-deposition treatment on the degree of film crystallization. XPS …


Evanescent Microwave Microscopy Of Porcine Skin Tissue, Richard A. Kleismit Jan 2008

Evanescent Microwave Microscopy Of Porcine Skin Tissue, Richard A. Kleismit

Browse all Theses and Dissertations

This thesis describes the application of a custom designed λ/4 resonant coaxial probe to measurements of the complex permittivity of in vitro freshly excised porcine skin tissue. The dielectric properties of the organic material within the near field of the tip of the probe frustrates the electric field and measurably changes the resonant frequency and quality factor Q of the coaxial sensor, where the change in resonant frequency and quality factor of a tuned resonance is measured as a function of tip-sample separation. The design of the probe enables better spatial resolution than previously developed probes. The following studies were …


Comparison Of Two Methods Of External Scatter Dose Contributions To The Contralateral Breast, James Cutlip Jan 2008

Comparison Of Two Methods Of External Scatter Dose Contributions To The Contralateral Breast, James Cutlip

Browse all Theses and Dissertations

The treatment outcomes of many forms of breast cancer have become very favorable. The usual standard of successful treatment of five years without a recurrence is not adequate any longer for breast cancer. Many patients live well beyond this time interval only to have a second malignancy develop in the contralateral breast ten or twenty years later. Boice et al (1992) found that there was a correlation between the amount of dose to the contralateral breast and the likelihood of a secondary malignancy forming.

The normal practice today is to use multi-leaf collimators (MLC) to modulate the photon beam in …