Full-Text Articles in Physics

Emit: An Apparatus To Test Time Reversal Invariance In Polarized Neutron Decay, H. P. Mumm, A. Garcia, L. Grout, M. Howe, L. P. Parazzoli, R. G. H. Robertson, K. M. Sundqvist, J. F. Wilkerson, S. J. Freedman, B. K. Fujikawa, L. J. Lising, M. S. Dewey, J. S. Nico, A. K. Thompson, T. E. Chupp, R. L. Cooper, K. P. Coulter, S. R. Hwang, R. C. Welsh, L. J. Broussard, C. A. Trull, F. E. Wietfeldt, Gordon L. Jones Dec 2004

Emit: An Apparatus To Test Time Reversal Invariance In Polarized Neutron Decay, H. P. Mumm, A. Garcia, L. Grout, M. Howe, L. P. Parazzoli, R. G. H. Robertson, K. M. Sundqvist, J. F. Wilkerson, S. J. Freedman, B. K. Fujikawa, L. J. Lising, M. S. Dewey, J. S. Nico, A. K. Thompson, T. E. Chupp, R. L. Cooper, K. P. Coulter, S. R. Hwang, R. C. Welsh, L. J. Broussard, C. A. Trull, F. E. Wietfeldt, Gordon L. Jones

Articles

We describe an apparatus used to measure the triple-correlation term (D (σ) over cap (n).p(e)xp(nu)) in the beta decay of polarized neutrons. The D coefficient is sensitive to possible violations of time reversal invariance. The detector has an octagonal symmetry that optimizes electron-proton coincidence rates and reduces systematic effects. A beam of longitudinally polarized cold neutrons passes through the detector chamber, where a small fraction undergo beta decay. The final-state protons are accelerated and focused onto arrays of cooled semiconductor diodes, while the coincident electrons are detected using panels of plastic scintillator. Details regarding the design and performance of the …


Stark Width And Shift Of The Neutral Argon 425.9 Nm Spectral Line, Vladimir Milosavljevic, Vida Zigman, Stevan Djenize Sep 2004

Stark Width And Shift Of The Neutral Argon 425.9 Nm Spectral Line, Vladimir Milosavljevic, Vida Zigman, Stevan Djenize

Articles

The Stark parameters, the width (W) and the shift (d), of the neutral argon (Ar I) 425.9 nm spectral line have been studied in a linear, low-pressure, optically thin pulsed arc discharge. The line shapes are measured in three different plasmas at about 16,000 K electron temperature (T) and about 7.0×1022 m−3 electron density (N). The separate electron and ion contributions to the total Stark width (Wt), i.e. We and Wi, as well as to the total Stark shift (dt), i.e. …


Reaction Thresholds In Doubly Special Relativity, Daniel Heyman '03, F. Hinterleitner, Seth Major May 2004

Reaction Thresholds In Doubly Special Relativity, Daniel Heyman '03, F. Hinterleitner, Seth Major

Articles

Two theories of special relativity with an additional invariant scale, “doubly special relativity,” are tested with calculations of particle process kinematics. Using the Judes-Visser modified conservation laws, thresholds are studied in both theories. In contrast with some linear approximations, which allow for particle processes forbidden in special relativity, both the Amelino-Camelia and Magueijo-Smolin frameworks allow no additional processes. To first order, the Amelino-Camelia framework thresholds are lowered and the Magueijo-Smolin framework thresholds may be raised or lowered.


Investigation Of The Diffusion Processes In Self-Processing Acrylamide-Based Photopolymer System, Izabela Naydenova, Raghavendra Jallapuram, Robert Howard, Suzanne Martin, Vincent Toal May 2004

Investigation Of The Diffusion Processes In Self-Processing Acrylamide-Based Photopolymer System, Izabela Naydenova, Raghavendra Jallapuram, Robert Howard, Suzanne Martin, Vincent Toal

Articles

Results from the investigation of the diffusion processes in a dry acrylamide-based photopolymer system are presented. The investigation is carried out in the context of experimental work on optimization of the high spatial frequency response of the photopolymer. Tracing the transmission holographic grating dynamics at short times of exposure is utilized to measure diffusion coefficients. The results reveal that two different diffusion processes contribute with opposite sign to the refractive index modulation responsible for the diffraction grating build up. Monomer diffusion from dark to bright fringe areas increases the refractive index modulation. It is characterized with diffusion constant D0=1.6E-7 cm2/s. …


Neutron Cross Sections For He-3 At Epithermal Energies, C. D. Keith, Z. Chowdhuri, D. R. Rich, W. M. Snow, J. D. Bowman, S. L. Penttila, D. A. Smith, M. B. Leuschner, V. R. Pomeroy, Gordon L. Jones, E. I. Sharapov Mar 2004

Neutron Cross Sections For He-3 At Epithermal Energies, C. D. Keith, Z. Chowdhuri, D. R. Rich, W. M. Snow, J. D. Bowman, S. L. Penttila, D. A. Smith, M. B. Leuschner, V. R. Pomeroy, Gordon L. Jones, E. I. Sharapov

Articles

High accuracy, absolute measurements of the neutron total cross section for He-3 are reported for incident neutron energies 0.1-400 eV. The measurements were performed at the LANSCE short-pulse neutron spallation source. Using the previously determined cross section for neutron elastic scattering, 3.367+/-0.019 b, we extract a new value for the energy dependence of the He-3(n,p)He-3 reaction cross section, sigma(np)=(849.77+/-0.14+/-1.02)E-1/2-(1.253+/-0.00+/-(+0.008)(-0.049))b, where the neutron energy is expressed in eV. The first uncertainty is statistical, the second systematic.


Objective Measurements Of Image Quality, Jacinta Browne, Amanda Watson, Nicholas Gibson, Nicholas Dudley, Alex Elliott Jan 2004

Objective Measurements Of Image Quality, Jacinta Browne, Amanda Watson, Nicholas Gibson, Nicholas Dudley, Alex Elliott

Articles

Tissue harmonic imaging (THI) and compound imaging have been reported clinically to improve contrast resolution, tissue differentiation and overall image quality. However, there have been limited studies to date to quantify objectively the improvements in image quality achieved with these new imaging techniques. The aim of this study was to quantify differences in image quality that exist between conventional B-mode imaging, harmonic imaging, compound imaging and harmonic compound imaging. An ATL HDI 5000 scanner with three probes (C5-2, L7-4 and L12-5) was tested with two different types of test object, the Gammex-RMI model 404 GS LE and the Gammex-RMI 403 …


An Investigation Of The Relationship Between In-Vitro And In-Vivo Ultrasound Image Quality Parameters, Jacinta Browne, Amanda Watson, Cathy Muir, Peter Hoskins, Alex Elliott Jan 2004

An Investigation Of The Relationship Between In-Vitro And In-Vivo Ultrasound Image Quality Parameters, Jacinta Browne, Amanda Watson, Cathy Muir, Peter Hoskins, Alex Elliott

Articles

The aim of this paper is to investigate the relationship between Bmode and colour Doppler technical test methods with the clinical perception of Bmode and Doppler invivo test parameters. It was found that technical and clinical comparisons between the Bmode test parameters: lateral resolution versus clinical resolution; anechoic target detection versus clinical noise; and penetration depth versus clinically useful penetration depth, demonstrated moderate correlations, (r= 0.69, p


Electronic Speckle Pattern Shearing Interferometer With A Photopolymer Holographyc Grating, Emilia Mihaylova, Izabela Naydenova, Suzanne Martin, Vincent Toal Jan 2004

Electronic Speckle Pattern Shearing Interferometer With A Photopolymer Holographyc Grating, Emilia Mihaylova, Izabela Naydenova, Suzanne Martin, Vincent Toal

Articles

A photopolymer holographic grating is used to produce the two sheared images in an electronic speckle pattern shearing interferometer. A ground glass screen following the grating serves the purpose of eliminating unwanted diffraction orders and to remove the requirement for the CCD camera to resolve the diffraction grating’s pitch. The sheared images on the ground glass are further imaged onto the CCD camera. The fringe pattern contrast was estimated to be above 90%. A validation of the system was done by comparing the theoretical phase difference distribution with the experimental data from the three point bending test.


Validation Of A Sensitivity Performance Index Test Protocol And Evaluation Of Colour Doppler Sensitivity For A Range Of Ultrasound Scanners, Jacinta Browne, Amanda Watson, Peter Hoskins, Alex Elliott Jan 2004

Validation Of A Sensitivity Performance Index Test Protocol And Evaluation Of Colour Doppler Sensitivity For A Range Of Ultrasound Scanners, Jacinta Browne, Amanda Watson, Peter Hoskins, Alex Elliott

Articles

The ability to detect flow is the most crucial aspect of an ultrasound (US) system because, if flow cannot be detected, no other aspect of performance matters. The objectives of this study were to validate a Doppler “sensitivity performance index,” a figure of merit, and to determine if it could be used to differentiate colour Doppler sensitivity performance in scanners of varying complexity. The sensitivity performance index was developed to give a combined measure of related aspects of sensitivity, such as the lowest detectable velocity, the vessel size and the penetration depth. The colour Doppler sensitivity was evaluated objectively as …