Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Physics

Design And Simulation Of An Induction Skull Melting System, Taide Tan May 2004

Design And Simulation Of An Induction Skull Melting System, Taide Tan

UNLV Theses, Dissertations, Professional Papers, and Capstones

Incorporating volatile actinides, mainly americium into a metallic fuel pin (MFP) has been a serious problem due to americium’s high vapor pressure. An Induction Skull Melting (ISM) system was identified by Argonne National Laboratory (ANL) as a potential furnace design to cast MFPs. Through the development of the ISM system, the nuclear waste feedstock can be melted and injected into the mold for fabricating MFPs in the advanced nuclear fuel cycles. The main phenomena in this system include: induction melting process, casting process and mass transfer process of americium. Issues related to ISM system design for casting MFPs are discussed …


Investigation And Calculation Of Dose Coefficients For Radionuclides Produced In A Spallation Neutron Source Using The Ensdf And Nubase Nuclear Databases, Yayun Song May 2004

Investigation And Calculation Of Dose Coefficients For Radionuclides Produced In A Spallation Neutron Source Using The Ensdf And Nubase Nuclear Databases, Yayun Song

UNLV Theses, Dissertations, Professional Papers, and Capstones

Dose coefficients are useful for risk assessment during the design and siting of accelerator-driven nuclear facilities including the Spallation Neutron Source. There are seventy-two radionuclides with half-lives equal to or greater than one minute that will be produced by the spallation of a mercury target for which no published dose coefficients exist. Out of these seventy-two, twenty-four currently have conflicting published nuclear data in the Evaluated Nuclear Structure Data Files (ENSDF) and the NUBASE data files. In this research these twenty-four radionuclides have been studied. Because of missing ENSDF records, internal and external dose coefficients were determined for only six …


Investigation Of The Corrosion Of Steel By Lead-Bismuth Eutectic (Lbe) Using Scanning Electron Microscopy And X-Ray Photoelectron Spectroscopy, Daniel Koury Dec 2002

Investigation Of The Corrosion Of Steel By Lead-Bismuth Eutectic (Lbe) Using Scanning Electron Microscopy And X-Ray Photoelectron Spectroscopy, Daniel Koury

UNLV Theses, Dissertations, Professional Papers, and Capstones

Lead Bismuth Eutectic (LBE) has been proposed for use in programs for accelerator transmutation of waste. LBE is the leading candidate material as a spallation target and an option for the sub-critical blanket coolant. The corrosion of 316 and 316L stainless steels by LBE has been studied using UNLV's facilities for Scanning Electron Microscopy (SEM) and X-ray Photoelectron Spectroscopy (XPS). We have compared exposed and unexposed samples and studied the differences. Some amount of surface contamination is present on the samples and has been removed by ionbeam etching. The unexposed samples reveal typical stainless steel characteristics: a chromium oxide passivation …