Analysis Of Cornell Electron-Positron Storage Ring Test Accelerator's Double Slit Visual Beam Size Monitor, Robert Campbell Sep 2012

Analysis Of Cornell Electron-Positron Storage Ring Test Accelerator's Double Slit Visual Beam Size Monitor, Robert Campbell

Physics

In the past year, a double slit interferometer was installed to measure the horizontal beam size in the Cornell Electron-Positron Storage Ring Test Accelerator (CesrTA) at Cornell University in Ithaca, NY. To better understand the systematics of this device, a replica of the CesrTA instrument was assembled at California Polytechnic State University San Luis Obispo. From the prototype, it was found that the device will produce a calculated beam size that agrees with measurements as long as it is optimized with the proper double slits for a small range of beam sizes.


Building And Characterization Of Laser Diodes As Well As System Design Of A Dual Wavelength Fabry-Perot Interferometer, Nicholas Czapla May 2012