Characterization Of Optical Constants For Uranium From 10 To 47 Nm, Nicole Brimhall, Nicholas Herrick, David D. Allred, R. Steven Turley, Michael Ware, Justin Peatross Mar 2010

Characterization Of Optical Constants For Uranium From 10 To 47 Nm, Nicole Brimhall, Nicholas Herrick, David D. Allred, R. Steven Turley, Michael Ware, Justin Peatross

Faculty Publications

We use a laser high-harmonics-based extreme-ultraviolet (EUV) polarimeter to determine the optical constants of elemental uranium in the wavelength range from 10 to 47 nm. The constants are extracted from the measure ratio of p-polarized to s-polarized reflectance from a thin uranium film deposited in situ. The film thickness is inferred from a spectroscopic ellipsometry measurement of the sample after complete oxidation in room air. Uranium has been used as a high-reflectance material in the EUV. However, difficulties with oxidation prevented its careful characterization previous to this study. We find that measured optical constants for uranium vary significantly from previous …


A Low-Voltage Retarding-Field Mott Polarimeter For Photocathode Characterization, J.L. Mccarter, M.L. Stutzman, K.W. Trantham, Timothy G. Anderson, A.M. Cook, Timothy J. Gay Jan 2010

A Low-Voltage Retarding-Field Mott Polarimeter For Photocathode Characterization, J.L. Mccarter, M.L. Stutzman, K.W. Trantham, Timothy G. Anderson, A.M. Cook, Timothy J. Gay

Timothy J. Gay Publications

Nuclear physics experiments at Thomas Jefferson National Accelerator Facility’s CEBAF rely on high polarization electron beams. We describe a recently commissioned system for prequalifying and studying photocathodes for CEBAF with a load-locked, low-voltage polarized electron source coupled to a compact retarding-field Mott polarimeter. The polarimeter uses simplified electrode structures and operates from 5 to 30 kV. The effective Sherman function for this device has been calibrated by comparison with the CEBAF 5 MeV Mott polarimeter. For elastic scattering from a thick gold target at 20 keV, the effective Sherman function is 0.201(5). Its maximum efficiency at 20 keV, defined as …


Near-Field Optical Interactions And Applications, David Haefner Jan 2010

Near-Field Optical Interactions And Applications, David Haefner

Electronic Theses and Dissertations

The propagation symmetry of electromagnetic fields is affected by encounters with material systems. The effects of such interactions, for example, modifications of intensity, phase, polarization, angular spectrum, frequency, etc. can be used to obtain information about the material system. However, the propagation of electromagnetic waves imposes a fundamental limit to the length scales over which the material properties can be observed. In the realm of near-field optics, this limitation is overcome only through a secondary interaction that couples the high-spatial-frequency (but non-propagating) field components to propagating waves that can be detected. The available information depends intrinsically on this secondary interaction, …


Far-Field Optical Nanoscopy Based On Continuous Wave Laser Stimulated Emission Depletion, C. Kuang, Wei Zhao, Guiren Wang Jan 2010

Far-Field Optical Nanoscopy Based On Continuous Wave Laser Stimulated Emission Depletion, C. Kuang, Wei Zhao, Guiren Wang

Faculty Publications

Stimulated emission depletion (STED) microscopy is one of the breakthrough technologies that belong to far-field optical microscopy and can achieve nanoscale spatial resolution. We demonstrate a far-field optical nanoscopy based on continuous wave lasers with different wavelengths, i.e., violet and green lasers for excitation and STED, respectively. Fluorescent dyes Coumarin 102 and Atto 390 are used for validating the depletion efficiency. Fluorescent nanoparticles are selected for characterizing the spatial resolution of the STED system. Linear scanning of the laser beams of the STED system along one line of a microscope slide, which is coated with the nanoparticles, indicates that a …