Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Physics

Instrument Matrix Of The Four-Detector Photopolarimeter: Physical Meaning Of Its Rows And Columns And Constraints On Its Elements, R. M.A. Azzam Jan 1990

Instrument Matrix Of The Four-Detector Photopolarimeter: Physical Meaning Of Its Rows And Columns And Constraints On Its Elements, R. M.A. Azzam

Electrical Engineering Faculty Publications

The four-detector photopolarimeter (FDP) is an arrangement of four photodetectors for measuring the state of polarization of light. The output current vector I of the FDP is related to the input Stokes vector S by I = AS, where A is the instrument matrix. The rows of A can be viewed as projection operators that determine the output currents of the detectors. This leads to the recognition of four special totally polarized input states, each of which maximizes the output of one detector. The associated four orthogonal states produce minimum signals. Because each detector is absorptive and its output is …


Measurement Of Magnetic Fluctuations By O-X Mode Conversion, L. L. Vahala, G. Vahala, N. Bretz Jan 1990

Measurement Of Magnetic Fluctuations By O-X Mode Conversion, L. L. Vahala, G. Vahala, N. Bretz

Electrical & Computer Engineering Faculty Publications

The possibility of measuring magnetic fluctuations in a fusion plasma is considered by examining the O→X mode conversion. Under certain conditions and with good angular resolution, this mode conversion can be attributed to the presence of magnetic fluctuations even though the level of these fluctuations is much lower than that of density fluctuations. Some nonideal effects such as mode polarization mismatch at the plasma edge are also discussed.


Influence Of Copper Doping On The Performance Of Optically Controlled Gaas Switches, St. T. Ko, V. K. Lakdawala, K. H. Schoenbach, M. S. Mazzola Jan 1990

Influence Of Copper Doping On The Performance Of Optically Controlled Gaas Switches, St. T. Ko, V. K. Lakdawala, K. H. Schoenbach, M. S. Mazzola

Electrical & Computer Engineering Faculty Publications

The influence of the copper concentration in silicon-doped gallium arsenide on the photoionization and photoquenching of charge carriers was studied both experimentally and theoretically. The studies indicate that the compensation ratio (NCu/NSi) is an important parameter for the GaAs:Si:Cu switch systems with regard to the turn-on and turn-off performance. The optimum copper concentration for the use of GaAs:Si:Cu as an optically controlled closing and opening switch is determined.


Principles And Clinical Applications Of Magnetic Resonance, Rao P. Gullapalli, Teresa T. Evans, Roger M. Hawk Jan 1990

Principles And Clinical Applications Of Magnetic Resonance, Rao P. Gullapalli, Teresa T. Evans, Roger M. Hawk

Journal of the Arkansas Academy of Science

A review is presented which covers the basic theory of nuclear magnetic resonance (NMR) with regard to angular momentum, magnetic moments, and the classical mechanical description of the NMR experiment. Longitudinal (T,) and Transverse (T2) relaxation times are defined as well as the basic pulse sequences used for their measurement. In particular, the 180°-t-90° and the Hahn Spin Echo pulse sequences are described in detail. Basic Magnetic Resonance Imaging (MRI) theory is discussed with regard to slice selection, frequency encoding, and phase encoding to define the imaged volume element. The equations defining the amount of Tt , T2 , and …