Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Physics

Carbon Multicharged Ion Generation From Laser-Spark Ion Source, Md. Mahmudur Rahman, Oguzhan Balki, Hani E. Elsayed-Ali Jan 2019

Carbon Multicharged Ion Generation From Laser-Spark Ion Source, Md. Mahmudur Rahman, Oguzhan Balki, Hani E. Elsayed-Ali

Electrical & Computer Engineering Faculty Publications

Multicharged carbon ions are generated by using a laser-assisted spark-discharge ion source. A Q-switched Nd:YAG laser pulse (1064 nm, 7 ns, ≤ 4.5 × 109 W/cm2) focused onto the surface of a glassy carbon target results in its ablation. The spark-discharge (∼1.2 J energy, ∼1 µs duration) is initiated along the direction of the plume propagation between the target surface and a grounded mesh that is parallel to the target surface. Ions emitted from the laser-spark plasma are detected by their time-of-flight using a Faraday cup. The ion energy-to-charge ratio is analyzed by a three-mesh retarding field …


Spatial Structure Of Ion Beams In An Expanding Plasma, Evan M. Aguirre, Earl E. Scime, Derek S. Thompson, Timothy N. Good Dec 2017

Spatial Structure Of Ion Beams In An Expanding Plasma, Evan M. Aguirre, Earl E. Scime, Derek S. Thompson, Timothy N. Good

Physics and Astronomy Faculty Publications

We report spatially resolved perpendicular and parallel, to the magnetic field, ion velocity distribution function (IVDF) measurements in an expanding argon helicon plasma. The parallel IVDFs, obtained through laser induced fluorescence (LIF), show an ion beam with v ≈ 8000 m/s flowing downstream and confined to the center of the discharge. The ion beam is measurable for tens of centimeters along the expansion axis before the LIF signal fades, likely a result of metastable quenching of the beam ions. The parallel ion beam velocity slows in agreement with expectations for the measured parallel electric field. The perpendicular IVDFs show an …


Power And Langmuir Probe Measurements Of H2 Rf Plasma, Alexander A. Stowell May 2016

Power And Langmuir Probe Measurements Of H2 Rf Plasma, Alexander A. Stowell

Macalester Journal of Physics and Astronomy

Methane based gases are often used to produce thin films of biomaterials, such as diamond-like carbon, through Plasma Enhanced Chemical Vapor Deposition. The characterization of the H2 plasma will give a deeper understanding of the physical processes occurring. Understanding these processes could lead to the optimization of the production of these thin films in the future. In this paper, we examine the H2 plasma using a Langmuir probe to gain information on the electron temperature and density of the plasma discharge. We measured electron temperatures of 6eV. Our Langmuir probe data indicates the electron temperature remains constant as …


Contamination Effects On Fixed-Bias Langmuir Probes, C.T. Steigies, Aroh Barjatya Jan 2012

Contamination Effects On Fixed-Bias Langmuir Probes, C.T. Steigies, Aroh Barjatya

Publications

Langmuir probes are standard instruments for plasma density measurements on many sounding rockets. These probes can be operated in swept-bias as well as in fixed-bias modes. In swept-bias Langmuir probes, contamination effects are frequently visible as a hysteresis between consecutive up and down voltage ramps. This hysteresis, if not corrected, leads to poorly determined plasma densities and temperatures. With a properly chosen sweep function, the contamination parameters can be determinedfromthemeasurementsandcorrectplasmaparameterscanthenbedetermined.Inthispaper, we study the contamination effects on fixed-bias Langmuir probes, where no hysteresis type effect is seen in the data. Even though the contamination is not evident from the measurements, it …


Predicted Properties Of Microhollow Cathode Discharges In Xenon, J. P. Boeuf, L. C. Pitchford, K. H. Schoenbach Jan 2005

Predicted Properties Of Microhollow Cathode Discharges In Xenon, J. P. Boeuf, L. C. Pitchford, K. H. Schoenbach

Bioelectrics Publications

A fluid model has been developed and used to help clarify the physical mechanisms occurring in microhollow cathode discharges (MHCD). Calculated current-voltage (I-V) characteristics and gas temperatures in xenon at 100 Torr are presented. Consistent with previous experimental results in similar conditions, we find a voltage maximum in the I-V characteristic. We show that this structure reflects a transition between a low-current, abnormal discharge localized inside the cylindrical hollow cathode to a higher-current, normal glow discharge sustained by electron emission from the outer surface of the cathode. This transition, due to the geometry of …


Electron Cyclotron Resonance Heating In Spherical Plasmas: O-X-Ebw Mode Conversion In Mast, Josef Preinhaelter, M. A. Irzak, Linda L. Vahala, George Vahala Jan 2001

Electron Cyclotron Resonance Heating In Spherical Plasmas: O-X-Ebw Mode Conversion In Mast, Josef Preinhaelter, M. A. Irzak, Linda L. Vahala, George Vahala

Electrical & Computer Engineering Faculty Publications

Using a full wave solution, the O-X-EBW mode conversion is examined for density and magnetic profiles in MAST. The effects of magnetic shear and the sharp density pedestal for H-mode operation are considered with an eye to understanding both electron cyclotron emission (ECE) and electron cyclotron resonance heating (ECRH).


Measurement Of Magnetic Fluctuations By O-X Mode Conversion, L. L. Vahala, G. Vahala, N. Bretz Jan 1990

Measurement Of Magnetic Fluctuations By O-X Mode Conversion, L. L. Vahala, G. Vahala, N. Bretz

Electrical & Computer Engineering Faculty Publications

The possibility of measuring magnetic fluctuations in a fusion plasma is considered by examining the O→X mode conversion. Under certain conditions and with good angular resolution, this mode conversion can be attributed to the presence of magnetic fluctuations even though the level of these fluctuations is much lower than that of density fluctuations. Some nonideal effects such as mode polarization mismatch at the plasma edge are also discussed.