Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- Lifetime (3)
- CRRES satellite (2)
- Dynamics (2)
- Electrostatic wave (2)
- Instability (2)
-
- Ionic current (2)
- MHD instability (2)
- MHD wave (2)
- Magnetic field (2)
- Magnetosphere (2)
- Magnetospheric physics (MHD waves and instabilities; magnetospheric configuration and dynamics) (2)
- Onde électrostatique (2)
- Orbit (2)
- Oscillation modes (2)
- Pc 5 micropulsation (2)
- Physique plasma (2)
- Plasma physics (2)
- Poloidal mode (2)
- Probability (2)
- Resonance (2)
- Ring current (2)
- Space plasma physics (waves and instabilities) (2)
- Spatial distribution (2)
- Statistical study (2)
- Sudden storm commencement (2)
- Toroidal mode (2)
- 100 keV beam line (1)
- Astrophysical plasma (1)
- Beam polarization measurements (1)
- Capacitance (1)
Articles 1 - 8 of 8
Full-Text Articles in Physics
Self‐Consistent Diffusive Lifetimes Of Weibel Magnetic Fields In Gamma‐Ray Bursts, C. H. Jaroschek, H. Lesch, R. A. Treumann
Self‐Consistent Diffusive Lifetimes Of Weibel Magnetic Fields In Gamma‐Ray Bursts, C. H. Jaroschek, H. Lesch, R. A. Treumann
Dartmouth Scholarship
Weibel filamentation in relativistic plasma shell collisions has been demonstrated as an efficient and fast mechanism for the generation of near-equipartition magnetic fields in self-consistent particle-in-cell (PIC) simulations. In generic γ-ray burst (GRB) models with kinetically dominated plasma outflow, sufficient strength and lifetime of magnetic fields are essential to validate synchrotron emission as the source of radiative outbursts. In this article we report on self-consistent PIC simulations of pair-plasma shell collisions in the highly relativistic regime with particle ensembles up to 5 × 108. Energy dependence of magnetic field generation in the Weibel process is discussed, and for …
Stark Width And Shift Of The Neutral Argon 425.9 Nm Spectral Line, Vladimir Milosavljevic, Vida Zigman, Stevan Djenize
Stark Width And Shift Of The Neutral Argon 425.9 Nm Spectral Line, Vladimir Milosavljevic, Vida Zigman, Stevan Djenize
Articles
The Stark parameters, the width (W) and the shift (d), of the neutral argon (Ar I) 425.9 nm spectral line have been studied in a linear, low-pressure, optically thin pulsed arc discharge. The line shapes are measured in three different plasmas at about 16,000 K electron temperature (T) and about 7.0×1022 m−3 electron density (N). The separate electron and ion contributions to the total Stark width (Wt), i.e. We and Wi, as well as to the total Stark shift (dt), i.e. …
High-Latitude Propagation Studies Using A Meridional Chain Of Lf/Mf/Hf Receivers, J Labelle
High-Latitude Propagation Studies Using A Meridional Chain Of Lf/Mf/Hf Receivers, J Labelle
Dartmouth Scholarship
For over a decade, Dartmouth College has oper- ated programmable radio receivers at multiple high-latitude sites covering the frequency range 100–5000 kHz with about a 1-s resolution. Besides detecting radio emissions of auro- ral origin, these receivers record characteristics of the iono- spheric propagation of natural and man-made signals, docu- menting well-known effects, such as the diurnal variation in the propagation characteristics of short and long waves, and also revealing more subtle effects. For example, at auroral zone sites in equinoctial conditions, the amplitudes of dis- tant transmissions on MF/HF frequencies are often enhanced by a few dB just before …
A Study Of Pc-5 Ulf Oscillations, M K. Hudson, R E. Denton, M R. Lessard, E G. Miftakhova, R R. Anderson
A Study Of Pc-5 Ulf Oscillations, M K. Hudson, R E. Denton, M R. Lessard, E G. Miftakhova, R R. Anderson
Dartmouth Scholarship
A study of Pc-5 magnetic pulsations using data from the Combined Release and Radiation Effects Satellite (CRRES) was carried out. Three-component dynamic mag- netic field spectrograms have been used to survey ULF pul- sation activity for the approximate fourteen month lifetime of CRRES. Two-hour panels of dynamic spectra were exam- ined to find events which fall into two basic categories: 1) toroidal modes (fundamental and harmonic resonances) and 2) poloidal modes, which include compressional oscillations. The occurence rates were determined as a function of L value and local time. The main result is a comparable probabil- ity of occurence of …
Excimer Emission From Cathode Boundary Layer Discharges, Mohamed Moselhy, Karl H. Schoenbach
Excimer Emission From Cathode Boundary Layer Discharges, Mohamed Moselhy, Karl H. Schoenbach
Bioelectrics Publications
The excimer emission from direct current glow discharges between a planar cathode and a ring-shaped anode of 0.75 and 1.5 mm diameter, respectively, separated by a gap of 250 μm, was studied in xenon and argon in a pressure range from 75 to 760 Torr. The thickness of the “cathode boundary layer” plasma, in the 100 μm range, and a discharge sustaining voltage of approximately 200 V, indicates that the discharge is restricted to the cathode fall and the negative glow. The radiant excimer emittance at 172 nm increases with pressure and reaches a value of 4 W/cm2 for …
Power Consideration In The Pulsed Dielectric Barrier Discharge At Atmospheric Pressure, M. Laroussi, X. Lu, V. Kolobov, R. Arslanbekov
Power Consideration In The Pulsed Dielectric Barrier Discharge At Atmospheric Pressure, M. Laroussi, X. Lu, V. Kolobov, R. Arslanbekov
Electrical & Computer Engineering Faculty Publications
Nonequilibrium, atmospheric pressure discharges are rapidly becoming an important technological component in material processing applications. Amongst their attractive features is the ability to achieve enhanced gas phase chemistry without the need for elevated gas temperatures. To further enhance the plasma chemistry, pulsed operation with pulse widths in the nanoseconds range has been suggested. We report on a specially designed, dielectric barrier discharge based diffuse pulsed discharge and its electrical characteristics. Two current pulses corresponding to two consecutive discharges are generated per voltage pulse. The second discharge, which occurs at the falling edge of the voltage pulse, is induced by the …
Influence Of Antenna Aiming On Ece In Mast, Josef Preinhaelter, Jakub Urban, Pavol Pavlo, Vladimir Shevchenko, Martin Valovič, Linda L. Vahala, George Vahala
Influence Of Antenna Aiming On Ece In Mast, Josef Preinhaelter, Jakub Urban, Pavol Pavlo, Vladimir Shevchenko, Martin Valovič, Linda L. Vahala, George Vahala
Electrical & Computer Engineering Faculty Publications
The effect of the direction of the detected beam on the intensity of ECE is studied. It is found that the combined effects of the strong dependence of the conversion efficiencey of O mode at the plasma resonance on the direction of the incident wave and the partial screening of the beam waist by the MAST vessel wall, can be responsible for the weakening of ECE emission for some frequencies. The theoretical model for ECE data interpretation on MAST has been significantly improved. New features of the model are as follows: the quasioptical treatment of the receiving antenna, interference, polarization …
Unique Electron Polarimeter Analyzing Power Comparison And Precision Spin-Based Energy Measurement, J. M. Grames, C. K. Sinclair, J. Mitchell, E. Chudakov, H. Fenker, A. Freyberger, D. W. Higinbotham, M. Poelker, M. Steigerwald, M. Tiefenback, Vipuli Dharmawardane
Unique Electron Polarimeter Analyzing Power Comparison And Precision Spin-Based Energy Measurement, J. M. Grames, C. K. Sinclair, J. Mitchell, E. Chudakov, H. Fenker, A. Freyberger, D. W. Higinbotham, M. Poelker, M. Steigerwald, M. Tiefenback, Vipuli Dharmawardane
Physics Faculty Publications
Precision measurements of the relative analyzing powers of five electron beam polarimeters, based on Compton, Moller, and Mott scattering, have been performed using the CEBAF accelerator at the Thomas Jefferson National Accelerator Facility ( Jefferson Laboratory). A Wien filter in the 100 keV beam line of the injector was used to vary the electron spin orientation exiting the injector. High statistical precision measurements of the scattering asymmetry as a function of the spin orientation were made with each polarimeter. Since each polarimeter receives beam with the same magnitude of polarization, these asymmetry measurements permit a high statistical precision comparison of …