Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Physics

Development Of A Slab-Based Monte Carlo Proton Dose Algorithm With A Robust Material-Dependent Nuclear Halo Model, John Wesley Chapman Jr Jun 2018

Development Of A Slab-Based Monte Carlo Proton Dose Algorithm With A Robust Material-Dependent Nuclear Halo Model, John Wesley Chapman Jr

LSU Doctoral Dissertations

Pencil beam algorithms (PBAs) are often utilized for dose calculation in proton therapy treatment planning because they are fast and accurate under most conditions. However, as discussed in Chapman et al (2017), the accuracy of a PBA can be limited under certain conditions because of two major assumptions: (1) the central-axis semi-infinite slab approximation; and, (2) the lack of material dependence in the nuclear halo model. To address these limitations, we transported individual protons using a class II condensed history Monte Carlo and added a novel energy loss method that scaled the nuclear halo equation in water to arbitrary geometry. …


Assessing The Potential Clinical Impact Of Variable Biological Effectiveness In Proton Radiotherapy, Christopher R. Peeler Ph.D. Dec 2016

Assessing The Potential Clinical Impact Of Variable Biological Effectiveness In Proton Radiotherapy, Christopher R. Peeler Ph.D.

Dissertations & Theses (Open Access)

It has long been known that proton radiotherapy has an increased biological effectiveness compared to traditional x-ray radiotherapy. This arises from the clustered nature of DNA damage produced by the energy deposition of protons along their tracks in medium. This effect is currently quantified in clinical settings by assigning protons a relative biological effectiveness (RBE) value of 1.1 corresponding to 10% increased effectiveness compared to photon radiation. Numerous studies have shown, however, that the RBE value of protons is variable and can deviate substantially from 1.1, but experimental data on RBE and clinical evidence of its variability remains limited.

The …


Volumetric Scintillation Dosimetry For Scanned Proton Beams, Daniel G. Robertson Aug 2014

Volumetric Scintillation Dosimetry For Scanned Proton Beams, Daniel G. Robertson

Dissertations & Theses (Open Access)

Scanned beam proton therapy is a promising cancer treatment modality which is becoming more widely available with the increasing number of proton radiotherapy centers. Scanned proton beams can produce complex 3D dose distributions, presenting a challenge for adequate quality assurance testing. Because each scanned beam dose measurement requires the delivery of the entire field, multiple measurements can be time consuming. These quality assurance challenges limit the number of patients who can be treated with this modality. The overall objective of this project is to increase the safety and availability of complex proton therapy treatments by developing a fast volumetric scintillation …


Image-Guided Proton Therapy For Online Dose-Evaluation And Adaptive Planning, Joey P. Cheung May 2014

Image-Guided Proton Therapy For Online Dose-Evaluation And Adaptive Planning, Joey P. Cheung

Dissertations & Theses (Open Access)

The main advantage for using protons in radiotherapy is their finite range in patients, allowing for potential improved sparing of normal tissues. However, this comes at a cost of increased sensitivity to range uncertainties. Density changes along the beam path will affect the proton range and the resultant dose distribution, making it difficult to estimate the impact of visible anatomic changes to the patient dose distribution. In order to better understand the effect of anatomy change on proton dose, some form of treatment-time verification is required and methods to correct for observed changes would be beneficial. Therefore, this project aims …


Evaluation Of Polymer Gel Dosimeters For Measurements Of Dose And Let In Proton Beams, Kevin M. Vredevoogd Dec 2012

Evaluation Of Polymer Gel Dosimeters For Measurements Of Dose And Let In Proton Beams, Kevin M. Vredevoogd

Dissertations & Theses (Open Access)

This project assessed the effectiveness of polymer gel dosimeters as tools for measuring the dose deposited by and LET of a proton beam. A total of three BANG® dosimeter formulations were evaluated: BANG®-3-Pro-2 BANGkits™ for dose measurement and two BANG®-3 variants, the LET-Baseline and LET-Meter dosimeters, for LET measurement. All dosimeters were read out using an OCT scanner. The basic characteristics of the BANGkits™ were assessed in a series of photon and electron irradiations. The dose-response relationship was found to be sigmoidal with a threshold for response of approximately 15 cGy. The active region of the dosimeter, the volume in …


Quantitative Comparison Of Late Effects Following Photon Versus Proton External-Beam Radiation Therapies: Toward An Evidence-Based Approach To Selecting A Treatment Modality, Rui Zhang Dec 2011

Quantitative Comparison Of Late Effects Following Photon Versus Proton External-Beam Radiation Therapies: Toward An Evidence-Based Approach To Selecting A Treatment Modality, Rui Zhang

Dissertations & Theses (Open Access)

Radiation therapy has been used as an effective treatment for malignancies in pediatric patients. However, in many cases, the side effects of radiation diminish these patients’ quality of life. In order to develop strategies to minimize radiogenic complications, one must first quantitatively estimate pediatric patients’ relative risk for radiogenic late effects, which has not become feasible till recently because of the calculational complexity. The goals of this work were to calculate the dose delivered to tissues and organs in pediatric patients during contemporary photon and proton radiotherapies; to estimate the corresponding risk of radiogenic second cancer and cardiac toxicity based …


Range Adaptive Proton Therapy For Prostate Cancer, Adam D. Melancon May 2010

Range Adaptive Proton Therapy For Prostate Cancer, Adam D. Melancon

Dissertations & Theses (Open Access)

Purpose: The rapid distal falloff of a proton beam allows for sparing of normal tissues distal to the target. However proton beams that aim directly towards critical structures are avoided due to concerns of range uncertainties, such as CT number conversion and anatomy variations. We propose to eliminate range uncertainty and enable prostate treatment with a single anterior beam by detecting the proton’s range at the prostate-rectal interface and adaptively adjusting the range in vivo and in real-time.

Materials and Methods: A prototype device, consisting of an endorectal liquid scintillation detector and dual-inverted Lucite wedges for range compensation, was designed …