Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Physics

Hepatocellular Carcinoma Image-Guided Intervention: Quantitative Characterization Of Reagents For Thermochemical Ablation, Emily A. Thompson May 2022

Hepatocellular Carcinoma Image-Guided Intervention: Quantitative Characterization Of Reagents For Thermochemical Ablation, Emily A. Thompson

Dissertations & Theses (Open Access)

Thermochemical ablation (TCA) is a minimally invasive therapy under development for hepatocellular carcinoma, a leading cause of cancer death worldwide. TCA utilizes acid-base chemistry delivered simultaneously to induce local ablation when administered. When delivered via a mixing catheter placed directly into the tumor, acid (e.g., AcOH) and base (e.g., NaOH) react to completion at the catheter tip, producing the acetate salt, water, and releasing heat (Δ>50°C) in sufficient quantities to induce lethal osmotic and thermal stress in tumor cells. However, these two reagents are not distinguishable from tissues with noninvasive imaging modalities, which makes monitoring the delivery of TCA …


Optimization Of Design Procedures For Delta Relaxation Enhanced Magnetic Resonance, Daniel J. Martire Feb 2018

Optimization Of Design Procedures For Delta Relaxation Enhanced Magnetic Resonance, Daniel J. Martire

Electronic Thesis and Dissertation Repository

Delta relaxation enhanced magnetic resonance (dreMR) is a magnetic resonance imaging (MRI) method that produces contrast based on longitudinal relaxation dispersion. Through modulation of the magnetic field using an actively-shielded, field-cycling insert coil, this technique increases probe specificity and suppresses remaining signal. However, significant improvements are needed. This thesis addresses two advancements in dreMR with a focus on optimizing design procedures. A general procedure was developed to design split power solenoid magnets. The procedure was then applied to the design of a switched-field exposure system. A coil was constructed and the method was validated. This procedure can be used for …


Advances In Image Acquisition And Filtering For Mri Neuroimaging At 7 Tesla, Andrew T. Curtis Sep 2014

Advances In Image Acquisition And Filtering For Mri Neuroimaging At 7 Tesla, Andrew T. Curtis

Electronic Thesis and Dissertation Repository

Performing magnetic resonance imaging at high magnetic field strength promises many improvements over low fields that are of direct benefit in functional neuroimaging. This includes the possibility of improved signal-to-noise levels, and increased BOLD functional contrast and spatial specificity. However, human MRI at 7T and above suffers from unique engineering challenges that limit the achievable gains. In this thesis, three technological developments are introduced, all of which address separate issues associated with functional magnetic resonance neuroimaging at very high magnetic field strengths.

First, the image homogeneity problem is addressed by investigating methods of RF shimming — modifying the excitation portion …


High Power Systems For Dynamic Field Control And Shielding In The Mr Environment, Dustin W. Haw Nov 2011

High Power Systems For Dynamic Field Control And Shielding In The Mr Environment, Dustin W. Haw

Electronic Thesis and Dissertation Repository

This thesis addresses several aspects of gradient and shim coil design and fabrication. New design techniques are coupled with experimental construction methods to expand small animal insert gradient and shim technology. The design techniques are also applied to other areas of magnetic resonance hardware.

A custom 2-axis gradient insert coil is designed and fabricated for the purpose of eddy current characterization. The construction tolerances were examined via bench top inductance measurements and eddy currents measurement inside a 7.0 T head-only MR system. A great deal of freedom is available when positioning shielding coils with respect to their corresponding primary coils …