Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Physics

Accessibility Of Home Blood Pressure Monitors For Blind And Visually Impaired People, Mark M. Uslan, Darren M. Burton, Thomas E. Wilson, Steven Taylor, Bruce S. Chertow, Jack E. Terry Feb 2014

Accessibility Of Home Blood Pressure Monitors For Blind And Visually Impaired People, Mark M. Uslan, Darren M. Burton, Thomas E. Wilson, Steven Taylor, Bruce S. Chertow, Jack E. Terry

Thomas E. Wilson

Background: The prevalence of hypertension comorbid with diabetes is a significant health care issue. Use of the home blood pressure monitor (HBPM) for aiding in the control of hypertension is noteworthy because of benefits that accrue from following a home measurement regimen. To be usable by blind and visually impaired patients, HBPMs must have speech output to convey all screen information, an easily readable visual display, identifiable controls that are easy to use, and an accessible user manual. Methods: Data on the physical aspects and the features and functions of nine Food and Drug Administration-approved HBPMs (eight of which were …


Enzyme Entrapment In Polyaniline Films Observed Via Florescence Anisotropy And Antiquenching, Louis R. Nemzer, Marissa Mccaffrey, Arthur J. Epstein Jan 2014

Enzyme Entrapment In Polyaniline Films Observed Via Florescence Anisotropy And Antiquenching, Louis R. Nemzer, Marissa Mccaffrey, Arthur J. Epstein

Louis R Nemzer

The facile entrapment of oxidoreductase enzymes within polyaniline polymer films by inducing hydrophobic collapse using phosphate buffered saline (PBS) has been shown to be a cost-effective method for fabricating organic biosensors. Here, we use fluorescence anisotropy measurements to verify enzyme immobilization and subsequent electron donation to the polymer matrix, both prerequisites for an effective biosensor. Specifically, we measure a three order of magnitude decrease in the ratio of the fluorescence to rotational lifetimes. In addition, the observed fluorescence antiquenching supports the previously proposed model that the polymer chain assumes a severely coiled conformation when exposed to PBS. These results help …


Xena: An Automated 'Open-Source' 129xe Hyperpolarizer For Clinical Use, Panayiotis Nikolaou, Aaron M. Coffey, Laura L. Walkup, Brogan M. Gust, Nicholas Whiting, Hayley Newton, Iga Muradyan, Mikayel Dabaghyan, Kaili Ranta, Gregory D. Moroz, Matthew S. Rosen, Samuel Patz, Michael J. Barlow, Eduard Y. Chekmenev, Boyd M. Goodson Dec 2013

Xena: An Automated 'Open-Source' 129xe Hyperpolarizer For Clinical Use, Panayiotis Nikolaou, Aaron M. Coffey, Laura L. Walkup, Brogan M. Gust, Nicholas Whiting, Hayley Newton, Iga Muradyan, Mikayel Dabaghyan, Kaili Ranta, Gregory D. Moroz, Matthew S. Rosen, Samuel Patz, Michael J. Barlow, Eduard Y. Chekmenev, Boyd M. Goodson

Nicholas Whiting

Here we provide a full report on the construction, components, and capabilities of our consortium’s “opensource”
large-scale (~1 L/h) 129Xe hyperpolarizer for clinical, pre-clinical, and materials NMR/MRI (Nikolaou et al., Proc. Natl. Acad. Sci. USA, 110, 14150 (2013)). The ‘hyperpolarizer’ is automated and built mostly of off-the-shelf components; moreover, it is designed to be cost-effective and installed in both research laboratories and clinical settings with materials costing less than $125,000. The device runs in the xenon-rich regime (up to 1800 Torr Xe in 0.5 L) in either stopped-flow or single-batch mode—making cryo-collection of the hyperpolarized gas unnecessary for many applications. …