Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 8 of 8

Full-Text Articles in Physics

Comparing Semi-Automated Segmentation Of Traditional-Resolution And High-Resolution Hyperpolarized 129xe Mri On Covid-19 Survivors, Tingting Wu Aug 2021

Comparing Semi-Automated Segmentation Of Traditional-Resolution And High-Resolution Hyperpolarized 129xe Mri On Covid-19 Survivors, Tingting Wu

Undergraduate Student Research Internships Conference

Hyperpolarized gas MRI using inert gases like Xe is a valuable tool in visualizing lung ventilation in patients, and can be used as a longitudinal monitoring tool for patients with lung diseases. However, use of this method requires segmentation and quantification of parameters such as ventilation defect percentage (VDP), which is often very subjective depending on the observer. This study aimed to determine the accuracy and consistency of VDP calculation using the same MRI scans from COVID-19 patients, but with high resolution and low (traditional) resolution versions. Using a MATLAB script developed previously, it was found that in general, using …


Developments In Pet-Mri For Radiotherapy Planning Applications, John Christian Patrick Mar 2017

Developments In Pet-Mri For Radiotherapy Planning Applications, John Christian Patrick

Electronic Thesis and Dissertation Repository

The hybridization of magnetic resonance imaging (MRI) and positron emission tomography (PET) provides the benefit of soft-tissue contrast and specific molecular information in a simultaneous acquisition. The applications of PET-MRI in radiotherapy are only starting to be realised. However, quantitative accuracy of PET relies on accurate attenuation correction (AC) of, not only the patient anatomy but also MRI hardware and current methods, which are prone to artefacts caused by dense materials. Quantitative accuracy of PET also relies on full characterization of patient motion during the scan. The simultaneity of PET-MRI makes it especially suited for motion correction. However, quality assurance …


Design Of Radio-Frequency Arrays For Ultra-High Field Mri, Ian R O Connell Jan 2017

Design Of Radio-Frequency Arrays For Ultra-High Field Mri, Ian R O Connell

Electronic Thesis and Dissertation Repository

Magnetic Resonance Imaging (MRI) is an indispensable, non-invasive diagnostic tool for the assessment of disease and function. As an investigational device, MRI has found routine use in both basic science research and medicine for both human and non-human subjects.

Due to the potential increase in spatial resolution, signal-to-noise ratio (SNR), and the ability to exploit novel tissue contrasts, the main magnetic field strength of human MRI scanners has steadily increased since inception. Beginning in the early 1980’s, 0.15 T human MRI scanners have steadily risen in main magnetic field strength with ultra-high field (UHF) 8 T MRI systems deemed to …


Optimizing Respiratory Gated Intensity Modulated Radiation Therapy Planning And Delivery Of Early-Stage Non-Small Cell Lung Cancer, Ilma Xhaferllari Jul 2016

Optimizing Respiratory Gated Intensity Modulated Radiation Therapy Planning And Delivery Of Early-Stage Non-Small Cell Lung Cancer, Ilma Xhaferllari

Electronic Thesis and Dissertation Repository

Stereotactic ablative body radiotherapy (SABR) is the standard of care for inoperable early-stage non-small cell lung cancer (NSCLC) patients. However, thoracic tumours are susceptible to respiratory motion and, if unaccounted for, can potentially lead to dosimetric uncertainties. Respiratory gating is one method that limits treatment delivery to portions of the respiratory cycle, but when combined with intensity-modulated radiotherapy (IMRT), requires rigorous verification. The goal of this thesis is to optimize respiratory gated IMRT treatment planning and develop image-guided strategies to verify the dose delivery for future early-stage NSCLC patients.

Retrospective treatment plans were generated for various IMRT delivery techniques, including …


Development Of A Small Animal Conformal Irradiator With Dual Energy X-Ray Computed Tomography Imaging For Kilovoltage Dosimetry, Michael D. Jensen Aug 2015

Development Of A Small Animal Conformal Irradiator With Dual Energy X-Ray Computed Tomography Imaging For Kilovoltage Dosimetry, Michael D. Jensen

Electronic Thesis and Dissertation Repository

External beam radiotherapy has become technically sophisticated with image guided radiation therapy (IGRT) and intensity modulated radiation therapy (IMRT). These technologies allow for precise delivery of radiation to geometric targets in cancer patients. However, many questions remain on how to best define targets based on biological information, such as functional imaging, and how to combine radiation with other cancer therapies. To help answer these questions, small animal preclinical studies are needed to generate data to inform clinical trials. However, the precise radiation delivery capabilities of IGRT and IMRT have not been available in the preclinical labs. To enable translational experiments …


The Impact Of Lateral Electron Disequilibrium On Stereotactic Body Radiation Therapy Of Lung Cancer, Brandon Disher Aug 2013

The Impact Of Lateral Electron Disequilibrium On Stereotactic Body Radiation Therapy Of Lung Cancer, Brandon Disher

Electronic Thesis and Dissertation Repository

Stereotactic Body Radiation Therapy (SBRT) is an effective treatment option for patients with inoperable early-stage lung cancer. SBRT uses online image-guidance technology [e.g. cone-beam CT (CBCT)] to focus small-fields of high energy x-rays onto a tumour to deliver ablative levels of radiation dose (e.g. 54 Gy) in a few treatment fractions (e.g. 3). For the combination of these treatment parameters and a low density lung, lateral electron disequilibrium (LED) can potentially occur, reducing lung and tumour doses. The goal of this thesis was to determine the impact of LED on stereotactic body radiation therapy for lung cancer.

The effect of …


Optimization Of A Boundary Element Approach To Electromagnet Design With Application To A Host Of Current Problems In Magnetic Resonance Imaging, Chad T. Harris Aug 2013

Optimization Of A Boundary Element Approach To Electromagnet Design With Application To A Host Of Current Problems In Magnetic Resonance Imaging, Chad T. Harris

Electronic Thesis and Dissertation Repository

Magnetic resonance imaging (MRI) has proven to be a valuable methodological approach in both basic research and clinical practice. However, significant hardware advances are still needed in order to further improve and extend the applications of the technique. The present dissertation predominantly addresses gradient and shim coil design (sub-systems of the MR system).

A design study to investigate gradient performance over a set of surface geometries ranging in curvature from planar to a full cylinder using the boundary element (BE) method is presented. The results of this study serve as a guide for future planar and pseudo-planar gradient systems for …


Mri-Based Attenuation Correction In Emission Computed Tomography, Harry R. Marshall May 2012

Mri-Based Attenuation Correction In Emission Computed Tomography, Harry R. Marshall

Electronic Thesis and Dissertation Repository

The hybridization of magnetic resonance imaging (MRI) with positron emission tomography (PET) or single photon emission computed tomography (SPECT) enables the collection of an assortment of biological data in spatial and temporal register. However, both PET and SPECT are subject to photon attenuation, a process that degrades image quality and precludes quantification. To correct for the effects of attenuation, the spatial distribution of linear attenuation coefficients (μ-coefficients) within and about the patient must be available. Unfortunately, extracting μ-coefficients from MRI is non-trivial. In this thesis, I explore the problem of MRI-based attenuation correction (AC) in emission tomography.

In particular, I …