Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Electrical and Computer Engineering

PDF

Series

Chemical elements

Articles 1 - 8 of 8

Full-Text Articles in Physics

Quantifying The Concentration And Penetration Depth Of Long-Lived Rons In Plasma Activated Water By Uv Absorption Spectroscopy, Zhijie Liu, Chunxi Zhou, Dingxin Liu, Tongtong He, Li Guo, Dehui Xu, Michael G. Kong Jan 2019

Quantifying The Concentration And Penetration Depth Of Long-Lived Rons In Plasma Activated Water By Uv Absorption Spectroscopy, Zhijie Liu, Chunxi Zhou, Dingxin Liu, Tongtong He, Li Guo, Dehui Xu, Michael G. Kong

Bioelectrics Publications

Reactive oxygen and reactive nitrogen species (RONS) are believed to play a key role in biomedical applications, which means that RONS must reach the target tissue to produce a therapeutic effect. Existing methods (electron spin spectrometry and microplate reading) to determine the RONS concentration are not suitable for experimental real-time measurements because they require adding an indicating reagent to the plasma-treated medium, which may alter the chemical composition of the medium. In this paper, we propose a method to measure the long-lived RONS concentration in plasma-activated water (PAW) by using UV absorption spectroscopy. Based on an analysis and fit of …


Investigation On The Rons And Bactericidal Effects Induced By He + O2 Cold Plasma Jets: In Open Air And In An Airtight Chamber, Han Xu, Dingxin Liu, Weitao Wang, Zhijie Liu, Li Guo, Mingzhe Rong, Michael G. Kong Nov 2018

Investigation On The Rons And Bactericidal Effects Induced By He + O2 Cold Plasma Jets: In Open Air And In An Airtight Chamber, Han Xu, Dingxin Liu, Weitao Wang, Zhijie Liu, Li Guo, Mingzhe Rong, Michael G. Kong

Bioelectrics Publications

He + O2 plasma jets in open air and in an airtight chamber are comparatively studied, with respect to their production of gaseous/aqueous reactive species and their antibacterial effects. Under the same discharge power, the plasma jet in open air has higher densities of gaseous reactive species and a higher concentration of aqueous H2O2 but lower concentrations of aqueous OH and O2-. In addition, the increase in the O2 ratio in He in both plasma jets causes a linear decrease in the population of gaseous reactive species, except for O(3p5P) …


Predicted Properties Of Microhollow Cathode Discharges In Xenon, J. P. Boeuf, L. C. Pitchford, K. H. Schoenbach Jan 2005

Predicted Properties Of Microhollow Cathode Discharges In Xenon, J. P. Boeuf, L. C. Pitchford, K. H. Schoenbach

Bioelectrics Publications

A fluid model has been developed and used to help clarify the physical mechanisms occurring in microhollow cathode discharges (MHCD). Calculated current-voltage (I-V) characteristics and gas temperatures in xenon at 100 Torr are presented. Consistent with previous experimental results in similar conditions, we find a voltage maximum in the I-V characteristic. We show that this structure reflects a transition between a low-current, abnormal discharge localized inside the cylindrical hollow cathode to a higher-current, normal glow discharge sustained by electron emission from the outer surface of the cathode. This transition, due to the geometry of …


Excimer Emission From Cathode Boundary Layer Discharges, Mohamed Moselhy, Karl H. Schoenbach Jan 2004

Excimer Emission From Cathode Boundary Layer Discharges, Mohamed Moselhy, Karl H. Schoenbach

Bioelectrics Publications

The excimer emission from direct current glow discharges between a planar cathode and a ring-shaped anode of 0.75 and 1.5 mm diameter, respectively, separated by a gap of 250 μm, was studied in xenon and argon in a pressure range from 75 to 760 Torr. The thickness of the “cathode boundary layer” plasma, in the 100 μm range, and a discharge sustaining voltage of approximately 200 V, indicates that the discharge is restricted to the cathode fall and the negative glow. The radiant excimer emittance at 172 nm increases with pressure and reaches a value of 4 W/cm2 for …


Xenon Excimer Emission From Pulsed Microhollow Cathode Discharges, M. Moselhy, R. H. Stark, K. H. Schoenbach, U. Kogelschatz Jan 2001

Xenon Excimer Emission From Pulsed Microhollow Cathode Discharges, M. Moselhy, R. H. Stark, K. H. Schoenbach, U. Kogelschatz

Bioelectrics Publications

By applying electrical pulses of 20 ns duration to xenon microplasmas, generated by direct current microhollow cathode discharges, we were able to increase the xenon excimer emission by more than an order of magnitude over direct current discharge excimer emission. For pulsed voltages in excess of 500 V, the optical power at 172 nm was found to increase exponentially with voltage. Largest values obtained were 2.75 W of vacuum-ultraviolet optical power emitted from a single microhollow cathode discharge in 400 Torr xenon with a 750 V pulse applied to a discharge. Highest radiative emittance was 15.2 W/cm2. The …


Series Operation Of Direct Current Xenon Chloride Excimer Sources, Ahmed El-Habachi, Wenhui Shi, Mohamed Moselhy, Robert H. Stark, Karl H. Schoenbach Jan 2000

Series Operation Of Direct Current Xenon Chloride Excimer Sources, Ahmed El-Habachi, Wenhui Shi, Mohamed Moselhy, Robert H. Stark, Karl H. Schoenbach

Bioelectrics Publications

Stable, direct current microhollow cathode discharges in mixtures of hydrochloric acid, hydrogen, xenon, and neon have been generated in a pressure range of 200–1150 Torr. The cathode hole diameter was 250 μm. Sustaining voltages range from 180 to 250 V at current levels of up to 5 mA. The discharges are strong sources of xenon chloride excimer emission at a wavelength of 308 nm. Internal efficiencies of approximately 3% have been reached at a pressure of 1050 Torr. The spectral radiant power at this pressure was measured as 5 mW/nm at 308 nm for a 3 mA discharge. By using …


Emission Of Excimer Radiation From Direct Current, High-Pressure Hollow Cathode Discharge, Ahmed El-Habachi, Karl H. Schoenbach Jan 1998

Emission Of Excimer Radiation From Direct Current, High-Pressure Hollow Cathode Discharge, Ahmed El-Habachi, Karl H. Schoenbach

Bioelectrics Publications

A novel, nonequilibrium, high-pressure, direct current discharge, the microhollow cathode discharge, has been found to be an intense source of xenon and argon excimer radiation peaking at wavelengths of 170 and 130 nm, respectively. In argon discharges with a 100 μm diam hollow cathode, the intensity of the excimer radiation increased by a factor of 5 over the pressure range from 100 to 800 mbar. In xenon discharges, the intensity at 170 nm increased by two orders of magnitude when the pressure was raised from 250 mbar to 1 bar. Sustaining voltages were 200 V for argon and 400 V …


Paschen's Law For A Hollow Cathode Discharge, H. Eichhorn, K. H. Schoenbach, T. Tessnow Jan 1993

Paschen's Law For A Hollow Cathode Discharge, H. Eichhorn, K. H. Schoenbach, T. Tessnow

Bioelectrics Publications

An expression for the breakdown voltage of a one‐dimensional hollow cathode discharge has been derived. The breakdown condition which corresponds to Paschen’s law contains, in addition to the first Townsend coefficient, and the secondary electron emission coefficient two parameters which characterize the reflecting action of the electric field and the lifetime of the electrons in the discharge. The breakdown voltage for a hollow cathode discharge in helium was calculated and compared to that of a glow discharge operating under similar conditions.