A 'Tissue Model' To Study The Barrier Effects Of Living Tissues On The Reactive Species Generated By Surface Air Discharge, Tongtong He, Dingxin Liu, Han Xu, Zhichao Liu, Dehui Xu, Dong Li, Qiosong Li, Mingzhe Rong, Michael G. Kong May 2016

A 'Tissue Model' To Study The Barrier Effects Of Living Tissues On The Reactive Species Generated By Surface Air Discharge, Tongtong He, Dingxin Liu, Han Xu, Zhichao Liu, Dehui Xu, Dong Li, Qiosong Li, Mingzhe Rong, Michael G. Kong

Bioelectrics Publications

Gelatin gels are used as surrogates of human tissues to study their barrier effects on incoming reactive oxygen and nitrogen species (RONS) generated by surface air discharge. The penetration depth of nitrite into gelatin gel is measured in real time during plasma treatment, and the permeabilities of nitrite, nitrate, O3 and H2O2 through gelatin gel films are quantified by measuring their concentrations in the water underneath such films after plasma treatment. It is found that the penetration speed of nitrite increases linearly with the mass fraction of water in the gelatin gels, and the permeabilities of …


Comparison Between Electropositive And Electronegative Cold Atmospheric-Pressure Plasmas: A Modelling Study, Ding X. Liu, Jia F. Li, Ai J. Yang, Xiao H. Wang, Ming Z. Rong, Michael G. Kong Jan 2016

Comparison Between Electropositive And Electronegative Cold Atmospheric-Pressure Plasmas: A Modelling Study, Ding X. Liu, Jia F. Li, Ai J. Yang, Xiao H. Wang, Ming Z. Rong, Michael G. Kong

Bioelectrics Publications

Cold atmospheric-pressure He + N2 and He + O2 plasmas are chosen as the representatives for electropositive and electronegative plasmas, of which the discharge characteristics are studied and then compared to each other by fluid models. As the increase of the impurity (N2 or O2) fraction from 0 to 10%, for He + N2 plasmas the electron density and ion density increase, the spatiotemporal distributions of electron density, ion density, electron temperature and electron generation rate change a little. On contrast, for He + O2 plasmas the electron density decreases, the ion density …


Rapid And Accurate C-V Measurements, Ji-Hong Kim, Pragya R. Shrestha, Jason P. Campbell, Jason T. Ryan, David Nminibapiel, Joseph J. Kopanski Jan 2016

Rapid And Accurate C-V Measurements, Ji-Hong Kim, Pragya R. Shrestha, Jason P. Campbell, Jason T. Ryan, David Nminibapiel, Joseph J. Kopanski

Electrical & Computer Engineering Faculty Publications

We report a new technique for the rapid measurement of full capacitance-voltage (C-V) characteristic curves. The displacement current from a 100-MHz applied sine wave, which swings from accumulation to strong inversion, is digitized directly using an oscilloscope from the MOS capacitor under test. A C-V curve can be constructed directly from this data but is severely distorted due to nonideal behavior of real measurement systems. The key advance of this paper is to extract the system response function using the same measurement setup and a known MOS capacitor. The system response correction to the measured C-V curve of the unknown …