Mipas Imk/Iaa Cfc-11 (Ccl3f) And Cfc-12 (Ccl2f2) Measurements: Accuracy, Precision And Long-Term Stability, E. Eckert, A. Laeng, S. Lossow, S. Kellmann, G. Stiller, T. Von Clarmann, N. Glatthor, M. Hopfner, M. Kiefer, H. Oelhaf, P. F. Bernath
Mipas Imk/Iaa Cfc-11 (Ccl3f) And Cfc-12 (Ccl2f2) Measurements: Accuracy, Precision And Long-Term Stability, E. Eckert, A. Laeng, S. Lossow, S. Kellmann, G. Stiller, T. Von Clarmann, N. Glatthor, M. Hopfner, M. Kiefer, H. Oelhaf, P. F. Bernath
Chemistry & Biochemistry Faculty Publications
Profiles of CFC-11 (CCl3F) and CFC-12 (CCl2F2) of the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) aboard the European satellite Envisat have been retrieved from versions MIPAS/4.61 to MI-PAS/4.62 and MIPAS/5.02 to MIPAS/5.06 level-1b data using the scientific level-2 processor run by Karlsruhe Institute of Technology (KIT), Institute of Meteorology and Climate Research (IMK) and Consejo Superior de Investigaciones Cientificas (CSIC), Instituto de Astrofisica de Andalucia (IAA). These profiles have been compared to measurements taken by the balloon-borne cryosampler, Mark IV (MkIV) and MIPAS-Balloon (MIPAS-B), the airborne MIPAS-STRatospheric aircraft (MIPAS-STR), the satellite-borne Atmospheric Chemistry …
Validation Of Mipas Imk/Iaa V5r_O3_224 Ozone Profiles, A. Laeng, U. Grabowski, T. Von Clarmann, G. Stiller, N. Glatthor, M. Höpfner, S. Kellmann, M. Kiefer, A. Linden, S. Lossow, P. F. Bernath
Validation Of Mipas Imk/Iaa V5r_O3_224 Ozone Profiles, A. Laeng, U. Grabowski, T. Von Clarmann, G. Stiller, N. Glatthor, M. Höpfner, S. Kellmann, M. Kiefer, A. Linden, S. Lossow, P. F. Bernath
Chemistry & Biochemistry Faculty Publications
We present the results of an extensive validation program of the most recent version of ozone vertical profiles retrieved with the IMK/IAA (Institute for Meteorology and Climate Research/Instituto de Astrofisica de Andalucia) MIPAS (Michelson Interferometer for Passive Atmospheric Sounding) research level 2 processor from version 5 spectral level 1 data. The time period covered corresponds to the reduced spectral resolution period of the MIPAS instrument, i.e., January 2005-April 2012. The comparison with satellite instruments includes all post-2005 satellite limb and occultation sensors that have measured the vertical profiles of tropospheric and stratospheric ozone: ACE-FTS, GOMOS, HALOE, HIRDLS, MLS, OSIRIS, POAM, …