Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Physics

Characterization Of A Trochoidal Electron Monochromator, Jesse Kruse Mar 2020

Characterization Of A Trochoidal Electron Monochromator, Jesse Kruse

Honors Theses

This thesis presents a quantitative study of a trochoidal electron monochromator and attempts to observe the 2p^53p^2 resonance in neon. A detailed description of the experimental apparatus, including the electron beam system, the vacuum system, and the light analysis system, is presented first. Then, we discuss the theory of how the electron beam is monochromatized, how we measured monochomatization, and how we analyze the light being emitted from the collision cell. The light analysis system is capable of accurately measuring the relative Stokes parameters for any polarization of light, and the electron beam system is capable of producing electron beams …


Design And Performance Of The Advanced-Light-Source Double-Crystal Monochromator, G. Jones, S. Ryce, Dennis W. Lindle, B. A. Karlin, J. C. Woicik, Rupert C. Perera Feb 1995

Design And Performance Of The Advanced-Light-Source Double-Crystal Monochromator, G. Jones, S. Ryce, Dennis W. Lindle, B. A. Karlin, J. C. Woicik, Rupert C. Perera

Chemistry and Biochemistry Faculty Research

A new “Cowan type” double-crystal monochromator, based on the boomerang design used at National Synchrotron Light Source (NSLS) beamline X-24A, has been developed for beamline 9.3.1 at the Advanced Light Source (ALS), a windowless ultrahigh vacuum beamline covering the 1-6 keV photon-energy range. Beamline 9.3.1 is designed to simultaneously achieve the goals of high energy resolution, high flux, and high brightness at the sample. The mechanical design of the monochromator has been simplified, and recent developments in technology have been included. Measured mechanical precision of the monochromator shows significant improvement over existing designs. In tests with x-rays at NSLS beamline …


High-Brightness Beamline For X-Ray Spectroscopy At The Advanced Light Source, Rupert C. Perera, G. Jones, Dennis W. Lindle Feb 1995

High-Brightness Beamline For X-Ray Spectroscopy At The Advanced Light Source, Rupert C. Perera, G. Jones, Dennis W. Lindle

Chemistry and Biochemistry Faculty Research

Beamline 9.3.1 at the Advanced Light Source (ALS) is a windowless beamline, covering the 1-6 keV photon-energy range, designed to achieve the goals of high energy resolution, high flux, and high brightness at the sample. When completed later this year, it will be the first ALS monochromatic hard-x-ray beamline, and its brightness will be an order-of-magnitude higher than presently available in this energy range. In addition, it will provide flux and resolution comparable to any other beamline now in operation. To achieve these goals, two technical improvements, relative to existing x-ray beamlines, were incorporated. First, a somewhat novel optical design …