Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Atomic, Molecular and Optical Physics

Air Force Institute of Technology

Spectroscopy

Articles 1 - 4 of 4

Full-Text Articles in Physics

Neutron Energy Tuning Assemblies For Nuclear Weapon Environment Applications At The National Ignition Facility, Nicholas J. Quartemont Sep 2021

Neutron Energy Tuning Assemblies For Nuclear Weapon Environment Applications At The National Ignition Facility, Nicholas J. Quartemont

Theses and Dissertations

An energy tuning assembly was developed to spectrally shape the National Ignition Facility deuterium-tritium fusion neutron source to a notional thermonuclear and prompt fission neutron spectrum to fulfill neutron source capability gaps. The experimental neutron environment was characterized with activation dosimetry, neutronics and covariance models, and unfolded to determine the as-fielded neutron spectrum. The first energy tuning assembly was demonstrated to create synthetic spectrally accurate post-detonation fission products, enhancing U.S. technical nuclear forensics capabilities. ATHENA, a second-generation energy tuning assembly, was also optimized to meet similar objectives, but the new platform neutron fluence efficiency was increased by a factor of …


Coupling Nuclear Induced Phonon Propagation With Conversion Electron Mössbauer Spectroscopy, Michael J. Parker Jun 2015

Coupling Nuclear Induced Phonon Propagation With Conversion Electron Mössbauer Spectroscopy, Michael J. Parker

Theses and Dissertations

Mössbauer spectroscopy is a very sensitive measurement technique (10-8 eV) which prompted motivation for the experiment described in this thesis. Namely, can a sensitive detection system be developed to detect nuclear recoils on the order of 10 to 100 of eVs? The hypothesis that this thesis tests is: Nuclear induced phonon bursts caused by Rutherford scattered alphas, decayed from 241Am, in a type-310 stainless steel material can couple with 7.3 keV conversion electron Mössbauer events at the other end of the material which will have a statistically significant effect on a Mössbauer spectrum. The phonon bursts produced by …


Spatial And Spectral Performance Of A Chromotomosynthetic Hyperspectral Imaging System, Randall L. Bostick, Glen P. Perram Mar 2012

Spatial And Spectral Performance Of A Chromotomosynthetic Hyperspectral Imaging System, Randall L. Bostick, Glen P. Perram

Faculty Publications

The spatial and spectral resolutions achievable by a prototype rotating prism chromotomosynthetic imaging (CTI) system operating in the visible spectrum are described. The instrument creates hyperspectral imagery by collecting a set of 2D images with each spectrally projected at a different rotation angle of the prism. Mathematical reconstruction techniques that have been well tested in the field of medical physics are used to reconstruct the data to produce the 3D hyperspectral image. The instrument operates with a 100 mm focusing lens in the spectral range of 400–900 nm with a field of view of 71.6 mrad and angular resolution of …


Use Of Diffuse Reflectance Spectroscopy To Determine Desorption Coefficients Of Trichioroethylene From Powdered Soils, Jay H. Foil Mar 1999

Use Of Diffuse Reflectance Spectroscopy To Determine Desorption Coefficients Of Trichioroethylene From Powdered Soils, Jay H. Foil

Theses and Dissertations

This laboratory thesis investigated the applicability of reflectance spectroscopy as a tool to measure desorption rates by directly observing the change in trichloroethylene bound to surface sites. Diffuse reflectance spectroscopy holds the promise of being a faster technique with minimal sample preparation time. Reflectance spectroscopy's dependence on the surface of the sample is its greatest advantage, as well as its greatest disadvantage. Both high and low resolution scans were made of different soil samples contaminated by trichloroethylene. After the technique of spectral subtraction was used, potential TCE signals were observed from the dolomitic limestone sample. Unfortunately, due to the low …