The Electrochemical Separation Of Curium And Americium: Quaterly Report August-December 2004, David W. Hatchett, Kenneth Czerwinski Dec 2004

The Electrochemical Separation Of Curium And Americium: Quaterly Report August-December 2004, David W. Hatchett, Kenneth Czerwinski

Separations Campaign (TRP)

This research report outlines the current status and progress associated with the electrochemical separation of Curium and Americium. The following pages outline the progress on our project to date. We have been actively performing research on this project for three months and are currently on schedule in terms of the proposed timelines.

The initial focus of the project involved setting up the laboratories for the studies outlined in the grant proposal. The instrumentation needed included an electrochemical work station that will perform the bulk of the electrochemical studies. This instrument will complement the electrochemical instrumentation in Dr. Hatchett’s laboratory and …


Probing Cation Antisite Disorder In Gd2ti2o7 Pyrochlore By Site-Specific Nexafs And Xps, Ponnusamy Nachimuthu, S. Thevuthasan, Mark H. Engelhard, W. J. Weber, D. K. Shuh, N. M. Hamdan, B. S. Mun, E. M. Adams, D. E. Mccready, V. Shutthanandan, Dennis W. Lindle, G. Balakrishnan, R. C. Ewing Sep 2004

Probing Cation Antisite Disorder In Gd2ti2o7 Pyrochlore By Site-Specific Nexafs And Xps, Ponnusamy Nachimuthu, S. Thevuthasan, Mark H. Engelhard, W. J. Weber, D. K. Shuh, N. M. Hamdan, B. S. Mun, E. M. Adams, D. E. Mccready, V. Shutthanandan, Dennis W. Lindle, G. Balakrishnan, R. C. Ewing

Chemistry and Biochemistry Faculty Research

Disorder in Gd2Ti2O7 is investigated by near-edge x-ray-absorption fine structure (NEXAFS) and x-ray photoelectron spectroscopy (XPS). NEXAFS shows Ti4+ ions occupy octahedral sites with a tetragonal distortion induced by vacant oxygen sites. O 1s XPS spectra obtained with a charge neutralization system from Gd2Ti2O7(100) and the Gd2Ti2O7 pyrochlore used by Chen et al. [Phys. Rev. Lett. 88, 105901 (2002)], both yielded a single peak, unlike the previous result on the latter that found two peaks. The current results give no evidence for …


Electrochemical Separation Of Curium And Americium, David W. Hatchett, Kenneth Czerwinski May 2004

Electrochemical Separation Of Curium And Americium, David W. Hatchett, Kenneth Czerwinski

Separations Campaign (TRP)

The objective of this project is to develop a method for the separation of Am from Cm based on electrochemical techniques. Electrochemical systems that allow the thermodynamics of actinide and lanthanide complexes to be systematically evaluated and tuned will be examined. The influence of complex formation on the ability to selectively isolate a given species electrochemically will be evaluated. Metal-ligand complex formation provides a useful derivation technique to increase solubility in solution environments that favor precipitation. In addition, the thermodynamic properties of a complex relative to the isolated species may be shifted to more suitably measurable electrochemical separation regimes. Electrochemical …


The Electrochemical Separation Of Curium And Americium: Quaterly Report January - March 2004, David W. Hatchett, Kenneth Czerwinski Mar 2004

The Electrochemical Separation Of Curium And Americium: Quaterly Report January - March 2004, David W. Hatchett, Kenneth Czerwinski

Separations Campaign (TRP)

This research report outlines the current status and progress associated with the electrochemical separation of Curium and Americium.

Data collection and analysis of the Ce3+/Ce4+ redox couple in various supporting electrolytes has continued. All electrolyte systems were investigated at Pt, Au, and Glassy Carbon working electrodes. Analysis of these data was accomplished by performing appropriate background subtractions to reveal net peaks due to Ce redox behavior. Successful identification of the Ce redox couple was achieved with all electrolyte/electrode systems, although a decline in peak resolution was observed with increasing acid concentration. Optimal conditions in this experiment were …


Hypothetical Thermodynamic Properties: The Boiling And Critical Temperatures Of Polyethylene And Polytetrafluoroethylene, James S. Chickos Jan 2004

Hypothetical Thermodynamic Properties: The Boiling And Critical Temperatures Of Polyethylene And Polytetrafluoroethylene, James S. Chickos

James Chickos

No abstract provided.


Performance Characteristics Of Beamline 6.3.1 From 200 Ev To 2000 Ev At The Advanced Light Source, Ponnusamy Nachimuthu, J. H. Underwood, C. D. Kemp, Eric M. Gullikson, Dennis W. Lindle, David K. Shuh, Rupert C. Perera Jan 2004

Performance Characteristics Of Beamline 6.3.1 From 200 Ev To 2000 Ev At The Advanced Light Source, Ponnusamy Nachimuthu, J. H. Underwood, C. D. Kemp, Eric M. Gullikson, Dennis W. Lindle, David K. Shuh, Rupert C. Perera

Chemistry and Biochemistry Faculty Research

Bend magnet beamline 6.3.1 at the Advanced Light Source operates from 200 eV to 2000 eV, primarily used for x-ray absorption fine structure investigations. The beamline optics consist of a compact, entrance-slitless, Hettrick-Underwood type variable-line-spacing plane-grating monochromator and refocusing mirrors to provide a 25 μm × 500 μm spot at the focal point in the reflectometer end station. Wavelength is scanned by the simple rotation of the grating and illuminates a fixed exit slit. The LabView based beamline control and data acquisition computer code has been implemented to provide a convenient interface to the user. The dedicated end station is …