Open Access. Powered by Scholars. Published by Universities.®

Selected Works

Waste incineration

Articles 1 - 8 of 8

Full-Text Articles in Environmental Health and Protection

Wpływ Zakładu Unieszkodliwiania Stałych Odpadów Komunalnych W Warszawie Na Jakość Powietrza, Robert Oleniacz, Jadwiga Antolak Nov 2010

Wpływ Zakładu Unieszkodliwiania Stałych Odpadów Komunalnych W Warszawie Na Jakość Powietrza, Robert Oleniacz, Jadwiga Antolak

Robert Oleniacz

The paper presents the results of air quality impact assessment carried out for the Municipal Solid Waste Disposal Plant in Warsaw. As part of the plant is working so far the only municipal solid waste incinerator in Poland. Following the evaluation, including data for the year 2008, it was found that it is a minor source of emissions to air and causes a slight air pollution. The highest maximum one-hour and annual average concentrations caused at ground level are many times lower than the respective reference (or permissible) values and background values for analyzed substances in the air. Increasing the …


Impact Of A Large Medical Waste Incinerator On Air Quality, Robert Oleniacz Dec 2009

Impact Of A Large Medical Waste Incinerator On Air Quality, Robert Oleniacz

Robert Oleniacz

In the paper, an assessment of the compliance with air emission limit values and the impact on air quality of one of the largest medical waste incinerators in Poland, with a total capacity of about 300 kg/h (two incineration lines) is presented. The assessment took the results of continuous and periodic measurements of emissions in the plant’s installation over a period of 12 months’ operation into account. For this period, a calculation was performed for the spread of air pollutants emitted by the two operating incineration lines. According to the analysis and calculations, the analysed medical waste incineration plant does …


Suchy System Oczyszczania Spalin Ze Spalania Odpadów Niebezpiecznych – Ocena Skuteczności Usuwania Substancji Gazowych I Możliwości Spełniania Standardów Emisyjnych, Robert Oleniacz Dec 2008

Suchy System Oczyszczania Spalin Ze Spalania Odpadów Niebezpiecznych – Ocena Skuteczności Usuwania Substancji Gazowych I Możliwości Spełniania Standardów Emisyjnych, Robert Oleniacz

Robert Oleniacz

The research object was a medical waste incineration plant with a flue-gas treatment system based on dry sorption agent injection to combustion gases before a high-efficiency particulate collector. A combustion system was consisted with the fluidized bed reactor (starved air gasifier) and the secondary combustion chamber. As the dry absorbent was used a mixture of high reactive hydrated lime and activated carbon. Activated carbon content in the mixture was 5-10 % by mass. The absorbent was injected in the minimal recommended amount (4-5 kg/h). Applied collector was a ceramic filter with total filtration area of 120 m2 and guaranteed outlet …


Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch Dec 2007

Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch

Robert Oleniacz

Construction of the Municipal Solid Waste Incineration (MSWI) plant is considered optimal in the Programme of Management of Solid Waste in Krakow as well as in proposed scenarios of Municipal Waste Management. Evaluation of impact of the incineration plant with a capacity of 255000 tons per year on air quality in Krakow is presented in this work. The evaluation is based on assumption that air pollutant emissions from the incinerator will be at the highest allowed level resulting from emission limit values for waste incineration plants with operation time each of two planned lines 7500 hours per year. Calculation results …


Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch Oct 2007

Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch

Robert Oleniacz

The work presents air quality impact assessment for the planned Municipal Solid Waste Incineration (MSWI) plant in Krakow with a established capacity of 255000 tons per year. The evaluation is based on assumption that air pollutant emissions from the incinerator will be at the highest allowed level resulting from emission limit values for waste incineration plants with operation time each of two planned lines 7500 hours per year. Calculation results for the one of the considered localization of the MSWI plant in Krakow (district of Nowa Huta) support the thesis that building the incineration plant of this size will not …


Średni Współczynnik Toksyczności Spalin Emitowanych Z Procesów Spopielania Odpadów Niebezpiecznych, Robert Oleniacz Aug 2001

Średni Współczynnik Toksyczności Spalin Emitowanych Z Procesów Spopielania Odpadów Niebezpiecznych, Robert Oleniacz

Robert Oleniacz

The paper presents the characteristics of the Average Toxicity Factor (ATF) for combustion gases emitted from incineration of hazardous waste. Proposals for the interpretation of this factor and the possibility of its use in assessing the degree of nuisance of the process in terms of the level of air pollutant emissions were also discussed.

English title: Average toxicity factor of combustion gases emitted from hazardous waste incineration.


Badania Emisji Chlorowodoru I Związków Fluoru Podczas Spalania Odpadów Niebezpiecznych, Marian Mazur, Robert Oleniacz, Marek Bogacki Dec 1996

Badania Emisji Chlorowodoru I Związków Fluoru Podczas Spalania Odpadów Niebezpiecznych, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the results of measurements of the concentration of hydrogen chloride (HCl) and fluoride compounds (as HF) in raw and purified combustion gases discharged from the incineration of selected hazardous wastes. The study included two installations operating on an industrial scale: a multiple hearth furnace and a rotary kiln incinerator equipped with a single wet flue gas cleaning systems. In the multiple hearth furnace was being incinerated sludge from coke industry. In the rotary kiln were being incinerated coal (coke) tars, contaminated cleaning rags, sawdust, used gloves, outdated pharmaceuticals and medicines, hospital waste, waste paints, varnish and lubricant, …


Emisja Zanieczyszczeń Ze Spalania Odpadów Farmaceutycznych I Poszpitalnych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki Dec 1996

Emisja Zanieczyszczeń Ze Spalania Odpadów Farmaceutycznych I Poszpitalnych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The work presents the problem of management and thermal treatment of medicines and hospital wastes and investigation results of incineration of these waste in the full-scale rotary kiln with wet gas cleaning equipment (alkaline scrubber). On the basis of measurements of air pollutant concentrations in combustion gases, maximum dose of these wastes in the feed to the kiln was specified in order to ensure a relatively low stack emissions using the hypothetical high-efficiency flue-gas treatment system.

English title: Pollutant emissions from incineration of pharmaceutical and hospital waste in a rotary kiln.