Emisja Chlorowodoru Ze Spalania Węgla W Kotle Pyłowym, Marian Mazur, Robert Oleniacz, Przemysław Szczygłowski, Marek Bogacki Dec 2004

Emisja Chlorowodoru Ze Spalania Węgla W Kotle Pyłowym, Marian Mazur, Robert Oleniacz, Przemysław Szczygłowski, Marek Bogacki

Robert Oleniacz

Emission of hydrogen chloride (HCl) from coal combustion is not controlled just like for example sulpfur dioxide emission. But HCl emission is also important, because chlorine content in some types of coal can reach the similar level to sulfur content. In the paper the measurement results of HCl emission to the air during combustion of three types of coal with law content of chlorine were presented. The researches were carried out for a steam pulverized coal boiler (max. boiler efficiency – 430 t/h) during three various loads (respectively 65, 80 and 95 % of maximum efficiency) without flue gas desulfurization. …


Metoda Oceny Trudności Oczyszczania I Toksyczności Spalin Powstających Podczas Spalania Odpadów, Robert Oleniacz Nov 2004

Metoda Oceny Trudności Oczyszczania I Toksyczności Spalin Powstających Podczas Spalania Odpadów, Robert Oleniacz

Robert Oleniacz

The paper presents a methodology for evaluating the cleaning difficulty and toxicity of combustion gases from waste incineration based on the knowledge of gases composition. This type of evaluation may be applicable to selection or modernization of flue gas cleaning systems for waste incineration plants and to comparative analy-sis of a pollution degree of raw (unclean) combustion gases. In the evaluation of the cleaning difficulty of gases six categories of difficulty have been identified for removal of selected substances or groups of substances. The evaluation is made individually for substances or groups of substances on condition their concentrations in flue …


Ocena Składu Gazów Odlotowych Z Procesów Spopielania Odpadów Niebezpiecznych Pod Kątem Trudności Oczyszczania I Toksyczności, Robert Oleniacz Dec 2001

Ocena Składu Gazów Odlotowych Z Procesów Spopielania Odpadów Niebezpiecznych Pod Kątem Trudności Oczyszczania I Toksyczności, Robert Oleniacz

Robert Oleniacz

Tightening of the European Union law in the field of the air emission limit values from waste incineration causes necessity for existing and new incineration plants to conform to the standards. It will often involve modernization of the flue gas cleaning system. Proposed in the paper the methodology of evaluation of the combustion gases composition in point of view cleaning difficulty should be useful to this end. Average toxicity factors for hazardous waste incineration flue gases were defined as well. Among other things they can be used in comparative analysis of the air pollutant concentration in the raw gas (before …


Emisja Zanieczyszczeń Ze Spalania Odpadów Niebezpiecznych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki Jan 1998

Emisja Zanieczyszczeń Ze Spalania Odpadów Niebezpiecznych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The article presents measurement results of air pollutant emissions from incineration of selected hazardous wastes in a full-scale rotary kiln equipped with afterburner and a wet installation for flue gas cleaning. This type of kiln is suitable for thermal disposal of many sorts of wastes, both solid and liquid. Four groups of waste were being incinerated during the tests: coke tars, medical (hospital) and pharmaceutical wastes added to greased cleaning materials, a sawdust and used gloves, varnish and lubrication wastes, as well as waste rubber and resins. The study was performed in order to answer the question: is the process …


Emisja Zanieczyszczeń Ze Spalania Odpadów Ściekowych W Piecu Półkowym, Robert Oleniacz, Marian Mazur, Marek Bogacki Dec 1996

Emisja Zanieczyszczeń Ze Spalania Odpadów Ściekowych W Piecu Półkowym, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The article presents incineration tests of silty-tar sludge produced in the wastewater treatment plant for coke industry. Sewage sludges were incinerated in a full-scale multiple hearth incinerator equipped with a wet flue-gas cleaning system (alkaline scrubber). Measurements of air pollutant emissions were carried out both before and after the cleaning system. The obtained results allow to conclude that the thermal utilization of sewage sludge in this type of installation might be just a little cumbersome for the environment, using the appropriate equipment for the purification of exhaust gases. The paper also specifies minimum exhaust gas cleaning performance that guarantees compliance …


Badania Emisji Chlorowodoru I Związków Fluoru Podczas Spalania Odpadów Niebezpiecznych, Marian Mazur, Robert Oleniacz, Marek Bogacki Dec 1996

Badania Emisji Chlorowodoru I Związków Fluoru Podczas Spalania Odpadów Niebezpiecznych, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the results of measurements of the concentration of hydrogen chloride (HCl) and fluoride compounds (as HF) in raw and purified combustion gases discharged from the incineration of selected hazardous wastes. The study included two installations operating on an industrial scale: a multiple hearth furnace and a rotary kiln incinerator equipped with a single wet flue gas cleaning systems. In the multiple hearth furnace was being incinerated sludge from coke industry. In the rotary kiln were being incinerated coal (coke) tars, contaminated cleaning rags, sawdust, used gloves, outdated pharmaceuticals and medicines, hospital waste, waste paints, varnish and lubricant, …


Emisja Zanieczyszczeń Ze Spalania Odpadów Farmaceutycznych I Poszpitalnych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki Dec 1996

Emisja Zanieczyszczeń Ze Spalania Odpadów Farmaceutycznych I Poszpitalnych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The work presents the problem of management and thermal treatment of medicines and hospital wastes and investigation results of incineration of these waste in the full-scale rotary kiln with wet gas cleaning equipment (alkaline scrubber). On the basis of measurements of air pollutant concentrations in combustion gases, maximum dose of these wastes in the feed to the kiln was specified in order to ensure a relatively low stack emissions using the hypothetical high-efficiency flue-gas treatment system.

English title: Pollutant emissions from incineration of pharmaceutical and hospital waste in a rotary kiln.


Emisja Zanieczyszczeń Ze Spalania Odpadów Przemysłowych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki Dec 1996

Emisja Zanieczyszczeń Ze Spalania Odpadów Przemysłowych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The paper presents the results of measurements of the concentration of selected pollutants in the flue gases from the incineration of industrial wastes in a full-scale rotary kiln. The study included three waste mixtures introduced into the kiln: 1) coal tar waste (tar origin of coke); 1) waste paints, varnish and lubricant; 3) resin and rubber waste. The article also assesses the effectiveness of the existing wet flue gas cleaning system (alkaline scrubber) and specifies minimum exhaust gas purifying performance guarantees compliance with European emission standards for waste incineration.

English title: Pollutant emissions from incineration of industrial waste in a …


Emisja Chlorowodoru I Związków Fluoru Ze Spalania Odpadów Niebezpiecznych, Marian Mazur, Robert Oleniacz, Marek Bogacki Jun 1996

Emisja Chlorowodoru I Związków Fluoru Ze Spalania Odpadów Niebezpiecznych, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the results of measurements of the concentration of hydrogen chloride (HCl) and fluoride compounds (as HF) in raw and purified combustion gases discharged from the incineration of selected hazardous wastes. The study included two installations operating on an industrial scale: a multiple hearth furnace and a rotary kiln incinerator equipped with a single wet flue gas cleaning systems. In the multiple hearth furnace was being incinerated sludge from coke industry. In the rotary kiln were being incinerated coal (coke) tars, contaminated cleaning rags, sawdust, used gloves, outdated pharmaceuticals and medicines, hospital waste, waste paints, varnish and lubricant, …