Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 16 of 16

Full-Text Articles in Environmental Health and Protection

Assessing Public Health Burden Associated With Exposure To Ambient Black Carbon In The United States, Ying Li, Daven K. Henze, Darby Jack, Barron H. Henderson, Patrick L. Kinney Apr 2017

Assessing Public Health Burden Associated With Exposure To Ambient Black Carbon In The United States, Ying Li, Daven K. Henze, Darby Jack, Barron H. Henderson, Patrick L. Kinney

Ying Li

Black carbon (BC) is a significant component of fine particulate matter (PM2.5) air pollution, which has been linked to a series of adverse health effects, in particular premature mortality. Recent scientific research indicates that BC also plays an important role in climate change. Therefore, controlling black carbon emissions provides an opportunity for a double dividend. This study quantifies the national burden of mortality and morbidity attributable to exposure to ambient BC in the United States (US). We use GEOS–Chem, a global 3-D model of atmospheric composition to estimate the 2010 annual average BC levels at 0.5 x 0.667° resolution, and …


Installation And Evaluation Of Permeable Pavement At Walden Pond State Reservation, Irvine W. Wei Aug 2013

Installation And Evaluation Of Permeable Pavement At Walden Pond State Reservation, Irvine W. Wei

Irvine W. Wei

Permeable pavements have been proposed for use in controlling surface runoff. A test installation was constructed at the Walden Pond State Reservation in Concord, Massachusetts to determine the feasibility of using permeable pavements in the New England environment. A brief history of the development and use of permeable pavements is provided. Background information, design methodology, and construction techniques are described for the data collection system and the parking area itself. All the following data are presented and discussed: mix gradation; pavement density; pavement, ground, and air temperatures; flow through permeable pavements; water quantity; water quality; and structural stability. This report …


Exploring The Effects Of Aperture Size, Aperture Variability And Matrix Properties On Biocolloid Retention In A Single, Saturated Fracture, Margaret Burke Jan 2012

Exploring The Effects Of Aperture Size, Aperture Variability And Matrix Properties On Biocolloid Retention In A Single, Saturated Fracture, Margaret Burke

Sarah E Dickson

No abstract provided.


Ocena Efektów Modernizacji Systemu Oczyszczania I Ewakuacji Spalin Na Wybranych Przykładach, Robert Oleniacz, Marcelina Groborz, Michał Ożóg Dec 2011

Ocena Efektów Modernizacji Systemu Oczyszczania I Ewakuacji Spalin Na Wybranych Przykładach, Robert Oleniacz, Marcelina Groborz, Michał Ożóg

Robert Oleniacz

The paper presents an assessment of changes in air emissions and impacts on air quality resulting from the modernization of flue gas cleaning and evacuation in two Polish coal-fired power plants. These modernizations were associated with the construction of flue gas desulphurisation systems and use for discharging desulphurized gases separate stacks with a height of 120 m. On the basis of analyzes and atmospheric dispersion modeling, it was found that the changes in the effective height of emitters (the apparent point of emission), due to additional reducing of flue gas volume in existing chimneys, caused that important ecological effects of …


Wpływ Zakładu Unieszkodliwiania Stałych Odpadów Komunalnych W Warszawie Na Jakość Powietrza, Robert Oleniacz, Jadwiga Antolak Nov 2010

Wpływ Zakładu Unieszkodliwiania Stałych Odpadów Komunalnych W Warszawie Na Jakość Powietrza, Robert Oleniacz, Jadwiga Antolak

Robert Oleniacz

The paper presents the results of air quality impact assessment carried out for the Municipal Solid Waste Disposal Plant in Warsaw. As part of the plant is working so far the only municipal solid waste incinerator in Poland. Following the evaluation, including data for the year 2008, it was found that it is a minor source of emissions to air and causes a slight air pollution. The highest maximum one-hour and annual average concentrations caused at ground level are many times lower than the respective reference (or permissible) values and background values for analyzed substances in the air. Increasing the …


Impact Of A Large Medical Waste Incinerator On Air Quality, Robert Oleniacz Dec 2009

Impact Of A Large Medical Waste Incinerator On Air Quality, Robert Oleniacz

Robert Oleniacz

In the paper, an assessment of the compliance with air emission limit values and the impact on air quality of one of the largest medical waste incinerators in Poland, with a total capacity of about 300 kg/h (two incineration lines) is presented. The assessment took the results of continuous and periodic measurements of emissions in the plant’s installation over a period of 12 months’ operation into account. For this period, a calculation was performed for the spread of air pollutants emitted by the two operating incineration lines. According to the analysis and calculations, the analysed medical waste incineration plant does …


Effect Of Spontaneous Gas Expansion And Mobilization On The Aqueous-Phase Concentrations Above A Dense Non-Aqueous Phase Liquid Pool., Kevin G. Mumford, James Smith, Sarah E. Dickson Dec 2009

Effect Of Spontaneous Gas Expansion And Mobilization On The Aqueous-Phase Concentrations Above A Dense Non-Aqueous Phase Liquid Pool., Kevin G. Mumford, James Smith, Sarah E. Dickson

Sarah E Dickson

This paper presents a framework to quantify the overall variability of the model estimations of Total Polychlorinated Biphenyls (Total PCBs) concentrations in the Niagara River on the basis of the uncertainty of few model parameters and the natural variability embedded in some of the model input variables. The results of the uncertainty analysis are used to understand the importance of stochastic model components and their effect on the overall reliability of the model output and to evaluate multiple sources of uncertainty that might need to be further studied. The uncertainty analysis is performed using a newly developed point estimate method, …


Suchy System Oczyszczania Spalin Ze Spalania Odpadów Niebezpiecznych – Ocena Skuteczności Usuwania Substancji Gazowych I Możliwości Spełniania Standardów Emisyjnych, Robert Oleniacz Dec 2008

Suchy System Oczyszczania Spalin Ze Spalania Odpadów Niebezpiecznych – Ocena Skuteczności Usuwania Substancji Gazowych I Możliwości Spełniania Standardów Emisyjnych, Robert Oleniacz

Robert Oleniacz

The research object was a medical waste incineration plant with a flue-gas treatment system based on dry sorption agent injection to combustion gases before a high-efficiency particulate collector. A combustion system was consisted with the fluidized bed reactor (starved air gasifier) and the secondary combustion chamber. As the dry absorbent was used a mixture of high reactive hydrated lime and activated carbon. Activated carbon content in the mixture was 5-10 % by mass. The absorbent was injected in the minimal recommended amount (4-5 kg/h). Applied collector was a ceramic filter with total filtration area of 120 m2 and guaranteed outlet …


Świadomość Społeczna Z Zakresu Niekontrolowanego Spalania Odpadów I Problemu Dioksyn, Robert Oleniacz, Anna Tomkowicz May 2008

Świadomość Społeczna Z Zakresu Niekontrolowanego Spalania Odpadów I Problemu Dioksyn, Robert Oleniacz, Anna Tomkowicz

Robert Oleniacz

The paper presents the problem of uncontrolled waste combustion in a rural community (Municipality Krościenko Wyżne, South-East Poland) and social awareness concerning the formation of dioxins using the results of the survey. In the questionnaire studies both combustion of wastes in household stoves was included as well as on the open space. The results of the survey showed a large scale of waste burning and low public awareness of inhabitants of the Polish village.

English title: Public awareness in the field of uncontrolled waste combustion and the problem of dioxins.


Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch Dec 2007

Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch

Robert Oleniacz

Construction of the Municipal Solid Waste Incineration (MSWI) plant is considered optimal in the Programme of Management of Solid Waste in Krakow as well as in proposed scenarios of Municipal Waste Management. Evaluation of impact of the incineration plant with a capacity of 255000 tons per year on air quality in Krakow is presented in this work. The evaluation is based on assumption that air pollutant emissions from the incinerator will be at the highest allowed level resulting from emission limit values for waste incineration plants with operation time each of two planned lines 7500 hours per year. Calculation results …


Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch Oct 2007

Ocena Wpływu Planowanego Zakładu Termicznego Przekształcania Odpadów Komunalnych Na Jakość Powietrza W Krakowie, Robert Oleniacz, Maria Pilch

Robert Oleniacz

The work presents air quality impact assessment for the planned Municipal Solid Waste Incineration (MSWI) plant in Krakow with a established capacity of 255000 tons per year. The evaluation is based on assumption that air pollutant emissions from the incinerator will be at the highest allowed level resulting from emission limit values for waste incineration plants with operation time each of two planned lines 7500 hours per year. Calculation results for the one of the considered localization of the MSWI plant in Krakow (district of Nowa Huta) support the thesis that building the incineration plant of this size will not …


Emisja Zanieczyszczeń Powietrza Z Procesu Grafityzacji Wyrobów Drobnych, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski Sep 2006

Emisja Zanieczyszczeń Powietrza Z Procesu Grafityzacji Wyrobów Drobnych, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski

Robert Oleniacz

The paper presents the research results of the air pollutant emissions from the graphitising process of fine carbon products in the Acheson furnace (discharge capacity 5,5 Mg). Research was performed for two kinds of raw material inputs (based on petroleum coke and pitch coke). Approximately 40-hours measurement series were carried out for each material including mainly such substances like carbon monoxide, hydrocarbons, nitrogen oxides, sulphur dioxide, hydrogen sulphide, carbon disulphide, ammonia, benzene, toluene, xylenes, total dust, tar substances and polycyclic aromatic hydrocarbons. Both average and maximum concentrations and mass streams in the flue gases and average emission factors were presented …


Ocena Funkcjonowania Instalacji Oczyszczania Gazów Odlotowych Z Procesu Grafityzacji Elektrod Węglowych W Sgl Carbon S.A. W Nowym Sączu, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski Aug 2003

Ocena Funkcjonowania Instalacji Oczyszczania Gazów Odlotowych Z Procesu Grafityzacji Elektrod Węglowych W Sgl Carbon S.A. W Nowym Sączu, Marian Mazur, Robert Oleniacz, Marek Bogacki, Przemysław Szczygłowski

Robert Oleniacz

The paper presents a general analysis of the suitability of individual elements of the flue-gas treatment system used in SGL Carbon SA in Nowy Sacz (Poland) for the graphitization process carried out in new LWG furnaces (Castner type). The flue-gas treatment system consisted of two installations: catalytic afterburning and flue-gas desulfurization. The analysis of the suitability of various methods of flue-gas treatment was based primarily on the assessment of the effects of their application, including the reduction of concentrations of selected components in post-graphitizing gases. The work also summarizes the results of evaluation of the functioning of the whole flue-gas …


Średni Współczynnik Toksyczności Spalin Emitowanych Z Procesów Spopielania Odpadów Niebezpiecznych, Robert Oleniacz Aug 2001

Średni Współczynnik Toksyczności Spalin Emitowanych Z Procesów Spopielania Odpadów Niebezpiecznych, Robert Oleniacz

Robert Oleniacz

The paper presents the characteristics of the Average Toxicity Factor (ATF) for combustion gases emitted from incineration of hazardous waste. Proposals for the interpretation of this factor and the possibility of its use in assessing the degree of nuisance of the process in terms of the level of air pollutant emissions were also discussed.

English title: Average toxicity factor of combustion gases emitted from hazardous waste incineration.


Badania Emisji Chlorowodoru I Związków Fluoru Podczas Spalania Odpadów Niebezpiecznych, Marian Mazur, Robert Oleniacz, Marek Bogacki Dec 1996

Badania Emisji Chlorowodoru I Związków Fluoru Podczas Spalania Odpadów Niebezpiecznych, Marian Mazur, Robert Oleniacz, Marek Bogacki

Robert Oleniacz

The paper presents the results of measurements of the concentration of hydrogen chloride (HCl) and fluoride compounds (as HF) in raw and purified combustion gases discharged from the incineration of selected hazardous wastes. The study included two installations operating on an industrial scale: a multiple hearth furnace and a rotary kiln incinerator equipped with a single wet flue gas cleaning systems. In the multiple hearth furnace was being incinerated sludge from coke industry. In the rotary kiln were being incinerated coal (coke) tars, contaminated cleaning rags, sawdust, used gloves, outdated pharmaceuticals and medicines, hospital waste, waste paints, varnish and lubricant, …


Emisja Zanieczyszczeń Ze Spalania Odpadów Farmaceutycznych I Poszpitalnych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki Dec 1996

Emisja Zanieczyszczeń Ze Spalania Odpadów Farmaceutycznych I Poszpitalnych W Piecu Obrotowym, Robert Oleniacz, Marian Mazur, Marek Bogacki

Robert Oleniacz

The work presents the problem of management and thermal treatment of medicines and hospital wastes and investigation results of incineration of these waste in the full-scale rotary kiln with wet gas cleaning equipment (alkaline scrubber). On the basis of measurements of air pollutant concentrations in combustion gases, maximum dose of these wastes in the feed to the kiln was specified in order to ensure a relatively low stack emissions using the hypothetical high-efficiency flue-gas treatment system.

English title: Pollutant emissions from incineration of pharmaceutical and hospital waste in a rotary kiln.